Fedders Ductless Split Remote Control Operating Instructions Manual

1
Press this button to select LIGHT on or off in the displayer. When the LIGHT on is
LIGHT button
set,the icon will be displayed and the
indicator light in the displayer will be on. When the LIGHT off is set, the icon will be displayed and the indicator light in the displayer will be off.
Names and functions of wireless remote control
ON/OFF button
ON/OFF
Remote control
Signal transmitter
AUTO COOL
DRY FAN
HEAT
(only for cooling and heating unit)
Don't drop or throw the remote control; Don't let any liquid in the remote control and
Note: Be sure that there are no obstructions between receiver and remote controller;
Middle fan
put the remote control directly under the sunlight or any place where is very hot.
Press this button, Auto, Cool,Dry, Fan,
Heat mode can be selected circularly.
MODE button
Auto mode is default while power on. Under Auto mode,the temperature will not be displayed; Under Heat mode, the initial value is 28
;Under other
modes,
the initial value is 25
Press this button, Sleep On and Sleep Off can be selected. After powered on,Sleep
SLEEP button
SLEEP
Off is defaulted. After the unit is turned off, the Sleep function is canceled. After Sleep function set up, the signal of Sleep will display. In this mode, the time of timer can be adjusted. Under Fan and Auto modes, this function is not available.
Press this button, Auto, Low, Middle, High
speed can be circularly selected. After
FAN button
FAN
powered on,Auto fan speed is default. Under Dehumidify mode, Low fan speed
only can be set up.
Low fan
High fan
Press this button, the clock can be set up,
signal blink and display.Within 5
CLOCK button
CLOCK
seconds, the value can be adjusted by pressing + or - button, if continuously press this button for 2 seconds above, in every 0.5 seconds, the value on ten place
of Minute will be increased 1. During blinking, repress the Clock button, signal will be constantly displayed and it denotes the setting succeeded. After powered on, 12:00 is defaulted to display and signal will be displayed. If there is signal be
value is Clock value, otherwise is Timer value.
displayed that denotes the current time
Operation of wireless remote control
F)
82
F)
77
Press this button, the unit will be turned on, press it once more, the unit will be turned
off. When turning on or turning off the unit,
the Timer, Sleep function will be canceled, but the presetting time is still remained.
adjustable, low fan speed is imperative,
Note:Under the Dry mode, the fan speed isn't
adjustable, low fan speed is imperative,
but when operating this button, the wireless
2
Remote control
BLOW button
BLOW
+ button
+
Presetting temperature can be decreased.
Press this button, the temperature can be
- button
-
set up, continuously press this button and hold for two seconds, the relative contents can quickly change, until unhold
this button and send the order that the (oF)signal will be displayed all the time.
The temperature adjustment is unav­ailable under the Auto mode, but the order can be sent by if pressing this button.
Names and functions of wireless remote control
Operation of wireless remote control
Press this button, can turn on or turn off the drying.In Cool and Dehumidifying mode,
this button,"BLOW" will be concealed, at this time the Blow function is turned off. After powered on, Blow OFF is defaulted.
When operating the ON/OFF button, or switching mode to Cool or Dehumidifying mode,the Blow function will keep the original status. If unit is turned off, Blow OFF only can be set up and send the signal. In Auto, Fan as well as Heat mode, Blow function can not be set up and there is no "BLOW" displaying.
press this button and will display "BLOW",
at this time the Blow is turned on. If repress
In Cool or Heat mode, press this button can turn on or turn off the Turbo function.
After turned on the Turbo function, its signal will be displayed. When switching the mode or changing fan speed, this
function will be canceled automatically.
For presetting temperature increasing.
Press this button,can set up the temperature, when unit is on . Continuously
press and hold this button for more than 2 seconds, the corresponding contents will be
changed
rapidly, until unpress the button
℃(℉)
laying all along. In Auto mode, the temp­erature can not be set up, but operate this button can send the signal. Centigrade setting range :16-30; Fahrenheit scale setting range 61-86.
then send the information, is disp-
with multifunction; For some function, which the model dosen't have, if press the corresponding button on the remote controller that the unit will keep the original
running
status.
Notice: This is a general use remote controller, it could be used for the air conditioners
3
Press this button, could select displaying the indoor setting temperature or indoor ambient temperature.When the indoor unit firstly power on it will display the setting temperature, if the temperature's displaying
status is changed from other status to" ", displays the ambient temperature, 5s later or within 5s, it receives other remote control
signal that will return to display the setting temperature. if the users haven't set up the temperature displaying status,that will display the setting temperature.
After powered on, the setting temperature displaying is defaulted, (according to
customers requirements to display, if there is no requirement that will default to display the presetting temperature and there is no icon displayed on wireless remote control). Press this button,
(When displaying ) , will display presetting temperature; (when displaying ) will display indoor ambient temperature,
TEMP button
TEMP
current displaying status will not be changed. If current displays indoor ambient temperature, if received the other remote control signal, it will display presetting temperature, 5s later, will back to display the ambient temperature.
(This function is applicable to partial of models)
(This function is applicable to partial of models)
TURBO button
TURBO
OFF
This is an universal use remote controller. If remote controller sends the following three kinds of status that the swing status of main
unit will be:
When the guide louver start to swing up and down, if turn off the Swing, the air guide louver will stop at current position.
which indicates the guide louver swings up and down between that all five positions.
Press this button, to set up swing angle, which circularly changes as below:
SWING UP AND DOWN BUTTON
TIMER ON
TIMER ON BUTTON
Timer On setting: Signal “ON” will blink and display, signal will conceal, the numerical section will become the timer on setting status. During 5 seconds blink, by pressing or button to adjust the time value of numerical section, every press of that button, the value will be increased or decreased 1 minute. Hold pressing or button, 2 seconds later, it quickly change, the way of change is: During the initial 2.5 seconds, ten numbers change in the one place of minute, then the one place is constant, ten numbers change in the tens place of minute at 2.5 seconds speed and carry. During 5s blink, press the Timer button, the timer setting succeeds. The Timer On has been set up, repress the timer On button, the Timer On will be canceled. Before setting the Timer, please adjust the Clock to the current actual time.
TIMER OFF BUTTON
Once press this key to enter into TIMER OFF setup, in which case the TIMER OFF icon will blink. The method of setting is the same
TIMER OFF
as for TIMER ON.
Remote control
Names and functions of wireless remote control
Operation of wireless remote control
with multifunction; For some function, which the model dosen't have, if press the corresponding button on the remote controller that the unit will keep the original
running status.
Notice: This is a general use remote controller, it could be used for the air conditioners
4
This function indicates that moisture on evaporator of indoor unit will be blowed after the unit
About blow function
is stopped to avoid mould.
1. Having set blow function on: After turning off the unit by pressing ON/OFF button indoor fan will continue running for about 10 min. at low speed. In this period, press blow button
to stop indoor fan directly.
2. Having set blow function off: After turning off the unit by pressing ON/OFF button, the complete unit will be off directly.
Operation of wireless remote control
Introduction for special function
1. After powered on, press ON/OFF button, the unit will start to run.(Note: When it is powered off, the guide louver of main unit will close automatically.)
2. Press MODE button, select desired running mode.
3. Pressing +or - button, to set the desired temperature. (It is unnecessary
to set the temp. at AUTO mode.)
4. Pressing FAN button, set fan speed, can select AUTO FAN, LOW, MID
and HIGH.
5. Pressing button, to select the swing.
1. Press SLEEP button, to set sleep.
2. Press TIMER ON and TIMER OFF button, can set the scheduled timer on
3. Press LIGHT button, to control the on and off of the displaying part of the
unit (This function may be not available for some units).
4. Press TURBO button, can realize the ON and OFF of TURBO
function.
or timer off.
Guide for operation- General operation
Guide for operation- Optional operation
When AUTO RUN mode is selected, the setting temperature will not be displayed on the LCD, the unit will be in accordance with the room temp. automatically to select the suitable
running method and to make ambient comfortable.
About turbo function
If start this function, the unit will run at super-high fan speed to cool or heat quickly so that the ambient temp. approachs the preset temp. as soon as possible.
About AUTO RUN
5
Press +and - buttons simultaneously to lock or unlock the keyboard. If the remote controller is locked, the icon
flicker for three times. If the keyboard is unlocked, the mark will disappear.
1. Press swing up and down button continuously more than 2s,the main unit will swing back and forth from up to down, and then loosen the button, the unit will stop swinging and present position of guide louver will be kept immediately.
2. Under swing up and down mode, when the status is switched from off to , if press this button again 2s later, status will switch to off status directly; if press this button again
within 2s,the change of swing status will also depend on the circulation sequence stated above.
About switch between Fahrenheit and Centigrade
Under status of unit off, press MODE and - buttons simultaneously to switch
℃ and .
About swing up and down
About lock
will be displayed on it, in which case, press any button, the mark will
Operation of wireless remote control
1.
Changing batteries and notices
6
4.
2.
3.
Slightly to press the place with , along the arrowhead direction to push the back cover of wireless
remote control. (As show in figure)
Take out the old batteries. (As show in figure) Insert two new AAA1.5V dry batteries, and pay attention to the polarity.
(As show in figure) Attach the back cover of wireless remote control. (As show in figure)
When changing the batteries, do not use the old or different batteries,
If the wireless remote control will not be used for a long time, please
otherwise, it can cause the malfunction of the wireless remote control.
take them out, and don't let the leakage liquid damage the wireless
remote control. The operation should be in its receiving range. It should be placed at where is 1m away from the TV set or stereo sound sets.
If the wireless remote control can not operate normally, please take them out,
after 30s later and reinsert, if they cannot normally run, please change them.
Sketch map for changing batteries
NOTE:
If the wireless remote control is lost
or broken, please use the manual switch
Auto mode, but the temperature and fan
button. At this time, the unit will run at the
To open the panel, the manual switch
is on the displayer box.
It's a special selective buttonfor the users ,who are not accustomed to the
light at sleeping.
Get the displayer indicator light on: When setting the light function,the mark will
pressing this button. In which case,the diss­player indicator light will be on if the AC receives
Get the displayer indicator light off: If cancel the light function,the mark will disap-
per on the remote controller screen by pressing this button. In which case, the displayer indicator light will
be off if the AC receives this signal.
Displayer indicator light control of indoor unit
display on the remote controller screen by
this signal.
Emergency operation
Emergency operation
speed cannot be changed. The operation was shown as below:
Turn on the unit: At unit turned off, press the button,the unit will run at Auto mode immediately.The microcomputer will accord
to the indoor temperature to select (Cooling, Heating, Fan) and obtain the comfortable effect.
Turn off the unit: At unit turned on, press the button, the unit will stop working.
Manual switch
Fig.3
7
Loading...