Residential & Light Commercial HVAC
Split System Air Conditioner
11⁄2 thru 5 Tons
208/230 Volt, 1-Phase, 60 Hz
Performance:
Efficiency rating of 13 SEER and 14 SEER
Cooling capacities from 1
Refrigerant Circuit:
Factory installed liquid line filter drier
Long life copper tubes, aluminum fins
State-of-the-art compressors
1
⁄2 to 5 tons
Rated in Accordance with ARI Standard 210.
Certification Applies Only When Used with
Proper Components as Listed with ARI.
Additional rating information can be found
at www.aridirectory.org
Large, wrap-around coil surface
Quality Built:
Galvaniz
1,000-hour salt spray, powder-coated finish
Powder-coated fan guard
Full louvered panel to protect coil
Formed base with 2
Limit
ed steel exterior cabinet with
1
⁄2" ground clearance
ed 5-year warranty on parts
Easy To Install:
Factory-charged with R-22 refrigerant
Only three screws to access electrical controls
Easy access to service valves
Max. Fuse or
Model
Number
C18ABD1VF 1 1⁄2 18,000 9.1 15 26
C24ABD1VF
C30ABD1VF
C36ACD1VF 3 36,000 18.7 30 32
C42ACD1VF
C48ACD1VF
C60ACD1VF 5 60,000 30.1 50 39 X 29
Siz
(tons)
2
1
2
⁄2 30,000
1
3
⁄2 42,000
4
BTUH
24,000
48,000
Nominal
e
Min. Cir
cuit
Ampacity
11.5 15 26
14.3
20.3
23.1
er H x W x D (inches) Pad Size (inches) Weight (lbs)
k
ea
Br
20
35 32
40
Operating Dimensions Min. Mounting Ship / Operating
1
⁄2 X 21 1⁄2 X 21 1⁄2 24 x 24 144 / 138
1
⁄2 X 21 1⁄2 X 21 1⁄2 24 x 24
1
32
⁄2 X 21 1⁄2 X 21 1⁄2 24 x 24
1
⁄2 X 29 1⁄2 X 29 1⁄2 32 x 32 189 / 180
1
⁄2 X 29 1⁄2 X 29 1⁄2 32 x 32
1
32
⁄2 X 29 1⁄2 X 29 1⁄2 32 x 32
1
⁄2 X 29 1⁄2 32 x 32 230 / 220
142 / 136
169 / 163
213 / 204
217 / 208

Product Specifications
PHYSICAL DATA
MODEL SIZE
PERFORMANCE DATA
NOMINAL CAPACITY (BTUH) 18,000 24,000 30,000 36,000 42,000 48,000 60,000
FAN DATA
FAN MOTOR TYPE PSC PSC PSC PSC PSC PSC PSC
HP 1/6 1/6 1/5 1/3 1/3 1/3 1/3
DIAMETER 18" 18" 18" 22" 22" 22" 24"
BLADE 3 3 3 3 3 3 3
RPM 1,050 1,050 1,050 1,050 1,050 1,050 950
CFM 1,800 1,800 1,800 3,400 3,400 3,400 4,000
OUTDOOR COIL
TYPE Enhanced Aluminum Plate Fin / Rifled Copper Tube
COIL FACE AREA (ft2) 9.5 9.5 12.2 18.2 18.2 18.2 22.2
O.D. 7mm 7mm 7mm 7mm 7mm 7mm 7mm
FPI / ROWS 18 -2 18 -2 18 -2 18-1 18-2 18 -2 18 -3
ELECTRICAL DATA (208/230 – 1-60, VOLTAGE RANGE 197V - 253V)
MINIMUM CIRCUIT AMPACITY - MCA (amps)
MAXIMUM OVERCURRENT PROTECTIVE DEVICE - MOCP(amps)
COMPRESSOR RLA (Rated Load Amps) 6.5 8.4 10.3 13.5 14.8 17 22.1
COMPRESSOR LRA (Locked Rotor Amps) 48 39 61 78 78 86 137
FAN MOTOR FLA (Full Load Amps) 1.0 1.0 1.4 1.8 1.8 1.8 1.9
REFRIGERANT CONNECTIONS
LIQUID LINE CONNECTION SIZE (In. OD) 3/8 3/8 3/8 3/8 3/8 3/8 1/2
SUCTION LINE CONNECTION SIZE
RECOMMENDED LINE SET LIQUID TUBE DIAMETER (In. OD) 3/8 3/8 3/8 3/8 3/8 3/8 1/2
RECOMMENDED LINE SET SUCTION DIAMETER
Y CHARGE R-22 - OZ.
ACTOR
F
(In. OD)
1
(In. OD)
18 24 30 36 42 48 60
9.1 11.5 14.3 18.7 20.3 23.1 30.1
2
15 15 20 30 35 40 50
3/4 3/4 7/8 7/8 7/8 7/8 1 1/8
3/4 3/4 7/8 7/8 7/8 7/8 1 1/8
72 106 91 87 128 150 204
NOTE: Control circuit is 24V on all units and requires external power source. Copper wire must be used from
service disconnect to unit. ALL motors/compressors contain internal overload protection.
Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will
1.
require larger wire sizes.
2. Time delay fuses may be used in place of HACR circuit breaker.
2
Specifications subject to change without notice.

Product Specifications
RI CERTIFIED COMBINATION PERFORMANCE RATINGS
A
UNIT
Outdoor Unit Indoor Unit
SIZE
18 C18ABD1VF
AC1A036 + FV80A070-4 TXV/TDR 18,000 13,500 14 12.0
24 C24ABD1VF
AC1A042A + FV80A070-4 TXV/TDR 21,600 17,000 14 12.2
AC1A042A + FV80A085-4 TXV/TDR 21,600 17,000 14 12.2
30 C30ABD1VF
AC1A060A + FV80A085-4 TXV/TDR 28,000 21,000 14 12.0
AC1A060A + FV80A115-5 TXV/TDR 28,000 21,000 14 12.0
36 C36ACD1VF
AC1A060A + FV80A085-4 TXV/TDR 35,000 25,500 14 11.8
Factory
Supplied
Enhancement
Cooling Capacity (BTUH)
Total Sensible
SEER
1
EER
AC1A024A TXV 17,500 12,750 13 11.3
AFPB24A1 TXV/TDR 17,500 12,750 13 11.3
AC1A024A TXV 21,600 15,750 13 11.3
AFPB24A1 TXV/TDR 21,600 15,750 13 11.3
AC1A030A TXV 26,600 19,500 13 11.4
AC1A036A TXV 26,600 19,500 13 11.4
AFPB36A1 TXV/TDR 26,600 19,500 13 11.4
AC1A036A TXV 34,000 24,750 13 11.4
AFPB36A1 TXV/TDR 34,000 24,750 13 11.4
AC1A060A + FV80A115-4 TXV/TDR 35,000 25,500 14 11.8
AC1A042A TXV 40,000 29,250 13 11.5
42 C42ACD1VF
AFPC48A1 TXV/TDR 40,000 29,250 13 11.5
AC1A060A + FV80A115-5 TXV/TDR 41,500 31,000 14 12.0
AC1A060A TXV 44,000 32,250 13 11.5
48 C48ACD1VF
AFPC48A1 TXV/TDR 44,000 32,250 13 11.5
AC1A060A TXV 53,000 38,750 13 11.5
60 C60ACD1VF
AFPC60A1 TXV/TDR 53,000 38,750 13 11.5
1. TDR required to obtain SEER
Notes:
Fedders coils include factory installed TXV
a.
contain the TDR as standard equipment.
b. TDR kit available as accessory
ested outdoor and indoor combinations have been tested in accordance with
T
c.
DOE test procedures for central air conditioners.
Above ratings based on 80ºF (27ºC) DB and 67ºF (19ºC) WB indoor entering
d.
air temperature and 95ºF (35ºC) DB air entering outdoor unit.
EER - Energy Efficiency Ratio
SEER - Seasonal Energy Ef
TDR - Time-Delay Relay
TXV - Thermostatic Expansion V
rating
. Fedders gas furnaces and air handlers
. Part Number TDR001A.
ficiency Ratio
alve
3
Specifications subject to change without notice.

Product Specifications
LINE SET LENGTH AND SIZE
BTUH
15 ft. 25 ft. 50 ft. 75 ft. 15 ft. 25 ft. 50 ft. 75 ft.
18 3/4" 3/4" 3/4" 3/4" 3/8" 3/8" 3/8" 3/8"
24 3/4" 3/4" 3/4" 3/4" 3/8" 3/8" 3/8" 3/8"
30 7/8" 7/8" 7/8" 7/8" 3/8" 3/8" 3/8" 3/8"
36 7/8" 7/8" 7/8" 7/8" 3/8" 3/8" 3/8" 3/8"
42 7/8" 7/8" 7/8" 1 1/8" 3/8" 3/8" 3/8" 3/8"
48 7/8" 7/8" 7/8" 1 1/8" 3/8" 3/8" 3/8" 3/8"
60 1 1/8" 1 1/8" 1 1/8" 1 1/8" 1/2" 1/2" 1/2" 1/2"
ecommended liquid and suction tube line size is for standard installations. The unit charge is correct for the outdoor unit, matched indoor coil and
R
5 feet of refrigerant tubing. For tubing length other than 15 feet, add or subtract the amount of refrigerant, using the difference in length multiplied
1
y the per foot value. These recommendations do not apply to Long Line Length Installations that exceed 75 feet or where there is more than 40 feet
b
ertical separation between indoor and outdoor units. (Lengths in excess of 75 feet or more than 40 feet vertical separation are not recommended.)
v
Note: See unit installation instructions for proper installation.
OUTDOOR
UNIT MODEL
C18ABD1VF
C24ABD1VF
C30ABD1VF
C36ACD1VF
C42ACD1VF AC1A042A 40,000 13 1,350
C48ACD1VF AC1A048A 44,000 13 1,550
C60ACD1VF AC1A060A 53,000 13 1,750
INDOOR UNIT
AC1A024A 17,500 13 650
AC1A036A + FV80A070-4 18,000 14 640
AC1A024A 21,600 13 810
AC1A042A + FV80A070-4 /
AC1A042A + FV80A085-4
AC1A030A 26,600 13 1,000
AC1A060A + FV80A085-4 /
AC1A060A + FV80A115-5
AC1A036A 34,000 13 1,150
AC1A060A + FV80A085-4 /
AC1A060A + FV80A115-5
SUCTION LINE SIZES LIQUID LINE SIZES
EXTENDED COOLING CAPACITIES
RATINGS AT
STANDARD CONDITIONS
CONDENSER ENTERING AIR TEMPERATURE DEGREES (F)
BTUH SEER* CFM 80 85 90 95 100 105 110 115
TOTAL 19,100 18,550 18,025 17,500 16,800 16,150 15,550 14,850
SENSIBLE 13,900 13,550 13,150 12,750 12,250 11,800 11,300 10,850
TOTAL 19,700 19,100 18,600 18,000 17,400 16,900 16,300 15,800
SENSIBLE 14,300 14,000 13,800 13,500 13,200 12,900 12,500 12,100
TOTAL 23,700 22,900 22,150 21,600 20,700 19,950 19,150 18,400
SENSIBLE 17,300 16,750 16,200 15,750 15,100 14,550 14,000 13,500
21,600 14 810
28,000 14 1,000
35,000 14 1,150
TOTAL 24,000 23,200 22,400 21,600 20,600 19,800 19,000 18,200
SENSIBLE 17,900 17,600 17,300 17,000 16,600 16,300 16,000 15,700
TOTAL 29,150 28,300 27,500 26,600 25,650 24,750 23,850 23,000
SENSIBLE 21,300 20,750 20,100 19,500 18,750 18,100 17,500 16,800
TOTAL 31,000 30,000 29,000 28,000 27,000 26,000 25,000 24,200
SENSIBLE 22,200 21,800 21,400 21,000 20,600 20,200 19,800 19,400
AL
TOT
SENSIBLE 27,000 26,450 25,650 24,750 24,000 23,250 22,500 21,650
TOT
SENSIBLE 27,200 26,600 26,200 25,500 25,000 24,600 24,200 23,600
TOTAL 43,450 42,300 41,150 40,000 38,800 37,650 36,550 35,500
SENSIBLE 31,750 30,850 30,100 29,250 28,350 27,500 26,700 25,950
TOTAL 47,650 46,400 45,250 44,000 42,700 41,550 40,330 39,200
SENSIBLE 34,750 33,850 33,100 32,250 31,200 30,500 29,400 28,650
TOT
SENSIBLE 41,250 40,500 39,550 38,750 37,850 36,950 36,150 35,500
37,000 36,200 35,150 34,000 32.900 31,800 30,700 29,650
AL
39,000 37,600 36,400 35,000 34,000 33,000 31,800 30,600
AL
56,600 55,400 54,150 53,000 51,800 50,600 49,500 48,600
*TDR required to obtain SEER rating.
4
Specifications subject to change without notice.

Product Specifications
Residential & Light Commercial
AC Condensing Units
Model Number Identification
C 24 A B D 1 V F * A
Product Type
C = Air Conditioner
CH = Heat Pump
Brand
Nominal Capacity
18 = 18,000 BTUH [5.28 kW]
24 = 24,000 BTUH [7.03 kW]
30 = 30,000 BTUH [8.79 kW]
36 = 36,000 BTUH [10.55 kW]
42 = 42,000 BTUH [12.31 kW]
48 = 48,000 BTUH [14.07 kW]
60 = 60,000 BTUH [17.58 kW]
Series
Chassis Size
B = 211⁄2" W x 211⁄2" D x H - Determined by BTU Size
C = 291⁄2" W x 291⁄2" D x H - Determined by BTU Size
Fitting Type
V = Sweat
Electrical Designation
1 = 208 / 230 Volts, 1 Phase, 60 Hz
2 = 220 Volts, 1 Phase, 50 Hz
3 = 208 / 230 Volts, 3 Phase, 60 Hz
4 = 460 Volts, 3 Phase, 60 Hz
5 = 230 Volts, 3 Phase, 50 Hz
6 = 380 Volts, 3 Phase, 50 Hz
Refrigerant Variations
D = R-22 Refrigerant
Fedders Corporation
505 Martinsville Rd.
Liberty Corner, NJ 07938
(908) 604-8686
Form No. F-C13
All product specifications reflect available information at the printing of this brochure.
Fedders reserves the right to revise or modify products and/or specifications without notice.
©2007 Fedders North America, Inc. Fedders is a registered trademark of Fedders North America, Inc.