Fantech, Inc. and Systemair Mfg.
certify that the ventilators shown
herein are licensed to bear the
AMCA Seal. The ratings shown are
based on tests and procedures
performed in accordance with
AMCA Publication 211 and AMCA
Publication 311 and comply with
the requirements of the AMCA
Certied Ratings Program.
Page 2
2
NoteWarning /
InformationTechnical
Important
note
Please read and save these instructions. Read carefully before
attempting to assemble, install, operate or maintain the product
described. Protect yourself and others by observing all safety
information. Failure to comply with instructions could result in personal
injury and/or property damage! Retain instructions for future reference.
Warning: Do not depend on any switch as sole means of disconnecting
power when installing or servicing the fan. If the power disconnect is outof-sight, lock it in the open position and tag to prevent application of
power. Failure to do so may result in fatal electrical shock.
1. Follow all local electrical and safety codes in the United States and
Canada, as well as the National Electrical Code (NEC) and the
Occupational Safety and Health Act (OSHA) in the United States,
and the Canadian Electric Code (CEC) in Canada.
2. Motor must be properly grounded by wiring with a grounded, metalclad raceway system, by using a separate ground wire connected to
the bare metal of the motor frame, or other suitable means.
3. Always disconnect power source before working on or near a motor
or its connected load. If the power disconnect point is out-of-sight,
lock it in the open position and tag to prevent unexpected application
of power.
Practical tip
information
Caution: In United States, to reduce the risk of injury to persons, OSHA
complying guards are required when fan is installed within 8 feet of floor,
ground, or working level.
Caution: In Canada to reduce, the risk of injury to persons, CSA
complying guards are required when fan is installed below 2.5 meters
(8.2 feet) above floor or grade level.
Warning: Motor will restart without warning after protector trips.
Caution: Do not touch motor. It may be hot enough to cause injury.
4. Be careful when touching the exterior of an operating motor. It may
be hot enough to be painful or cause injury. With modern motors,
this condition is normal if operated at rated load and voltage;
modern motors are built to operate at higher temperatures.
5. Protect the power cable from coming in contact with sharp objects.
6. Do not kink power cable and never allow the cable to come in contact
with oil, grease, hot surfaces, or chemicals
7. Make certain that the power source conforms to the requirements of
your equipment.
fantech
Page 3
Description
Designed to ventilate stores, offices, factories, shops, farm buildings, etc. Efficient, easy-to install exhaust fan with automatic shutters. 7” to 36”
diameter deep pitched propeller. Steel intake guard complies with United States OSHA Federal 1/2” max. opening requirement. Wire guard has charcoal gray metallic polyester finish to resist corrosion.
NOTE: These units are designed for wall mounting only.
Optional Accessories: Speed controllers, 3 amp model 5ACC03SC, 5 amp model 5ACC05SC, 6 amp model 5ACC06AC,
and 10 amp model 5ACC1OSC.
Unpacking
1. Inspect carefully for any damage that may have occurred during transit.
2. Before installing, rotate the propeller to be sure there are no obstructions which would interfere with proper operation. Adjust as required.
Dimensions
3
A Sq.
D
B
E
F
Air ow
C Sq.
G
Table 1: Dimensional data
ModelABCDEFG
2SHE 0721*11 1/
2SHE 1021*13 1/
2SHE 1221*15 1/
2SHE 1621*19 1/
2SHE 1871*21 1/
2SHE 20B1W*23 1/
2SHE 24B1W*27 1/
2SHE 30C133 1/
2SHE 36D139 1/
Dimensional information is in inches.
* - Speed Controllable
8
8
8
8
8
8
8
8
8
4 15/
16
5 9/
16
6133 9/
6 13/
16
8 1/
2
10 3/
4
9 3/
4
13 1/
8
13 1/
8
8 1/
2
10 1/
2
1710 1/
18 1/
2
2110 1/
253 9/
3110 1/
3710 1/
3 9/
10 1/
3 9/
16
2
16
2
16
2
16
2
2
5 3/
5 3/
5 3/
5 3/
5 3/
5 3/
5 3/
5 3/
5 3/
4
4
4
4
4
4
4
4
4
3
3
3
3
3
3
3
3
3
1
/4 X 1/
1
/4 X 1/
1
/4 X 1/
1
/4 X 1/
1
/4 X 1/
1
/4 X 1/
1
/4 X 1/
1
/4 X 1/
1
/4 X 1/
2
2
2
2
2
2
2
2
2
fantech
Page 4
4
Installation
1. Frame in the wall opening with 2 x 4” lumber, to form a square. The
opening should be 1/2” larger than the shutter frame (See Figure 1,
dimension C).
2. Insert the fan (shutter end rst) through the opening. Attach the
ange to the frame using nails or screws (Not furnished).
3. Connect power supply to the motor using an approved wiring method.
See preferred wiring diagram in Figure 2
The fan motor must be securely and adequately grounded to a
suitable electrical ground such as a grounded water pipe or
ground wire system!
4. Before activating the fan, double-check to ensure that there are no
obstructions (framing, stud, shutter, etc.) which would interfere with
proper fan operation.
Operation
1. Keep the area free of objects that could impede air ow on either the
intake side or exhaust side of fan.
2. For proper exhausting, a window, door, or louver should be opened on
the opposite side of the area to be ventilated.
3. Turn the fan ON, the shutter will open automatically. When the unit is
turned OFF, the shutter will close.
Single Speed
Single Speed
Figure 2 - Wiring Diagrams
White
Black
Common Line 1
Common Line 2
Common Line 1
Common Line 2
Maintenance
Do not depend on any switch as sole means of disconnecting
power when installing or servicing the fan. If the power
disconnect is out-of-sight, lock it in the open position and tag
to prevent application of power. Failure to do so may result in
fatal electrical shock.
Minor and routine
1. Disconnect and lock out power source before servicing.
2. Lubricate the motor sleeve bearings every six months using S.A.E. 20
non-detergent oil.
3. Ball bearing motors are permanently lubricated at the factory. No
further lubrication is necessary.
4. Periodically clean the propeller and motor of any excessive
accumulation of dirt.
Parts and replacement
1. Refer to Figure 3 for correct positioning of parts.
2. Refer to “Repair Parts List” for ordering information.
3. Disconnect power before servicing.
4. Remove the four screws and nuts holding the guard to the venturi
panel. Remove the guard/motor/propeller assembly.
5. Loosen the setscrew on propeller hub and remove the propeller.
Do not repair damaged propellers. They should be replaced
with a properly balanced replacement.
6. Loosen the nuts holding motor on guard and remove motor. On split
phase models, it is also necessary to loosen and remove bolt and nut
holding yoke brace to motor yoke tabs.
7. Reassemble the unit in reverse order of disassembly.
Fan inoperative1. Blown fuse or open circuit breaker
2. Defective motor
3. Speed control set too low
Insufcient air ow1. Blocked intake or exhaust opening
2. Low voltage
3. Speed control set too low
1. Relubricate motor bearings
2. Tighten setscrews in hub
3. Replace propeller
1. Replace fuse or reset circuit breaker
2. Repair or replace motor
3. Increase speed with controller
1. Clear opening of obstruction or increase size of opening
2. Determine cause and correct
3. Increase speed with controller
fantech
Page 7
Warranty
7
Fantech, Inc. warrants to the original purchaser that our products will be
free from defects in material and workmanship for a period of one (1)
year from the date of shipment. THIS IS OUR SOLE AND EXCLUSlVE
PRODUCT WARRANTY AND IS IN LIEU OF AND EXCLUDES ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED, ARISING BY OPERATION OF LAW
OR OTHERWISE, INCLUDING WITHOUT LIMITATION, MERCHANTABILITY
AND FITNESS FOR A PARTICULAR PURPOSE WHETHER OR NOT THE
PURPOSE OR USE HAS BEEN DISCLOSED TO US IN SPECIFICATIONS,
DRAWINGS DR OTHERWISE, AND WHETHER OR NOT OUR PRODUCTS
ARE SPECIFICALLY DESIGNED AND/OR MANUFACTURED BY US FOR
PURCHASER’S USE OR PURPOSE.
This warranty does not cover any losses or damages due to misuse,
accident, abuse, neglect, normal wear and tear, negligence [other than
ours), unauthorized alteration, use beyond rated capacity, or improper
installation, maintenance or application. This warranty shall be null and
void to the extent that purchaser supplied incorrect information to us
about the necessary product specifications or the environment in which
the products were to be used, and our selection or design of the products for the purchaser was based in part on such information.
If within thirty (30) days after purchaser’s discovery of any warranty
defects within the warranty period, purchaser notifies us thereof in writing, we shall, at our option, repair, correct or replace F.O.B. point of
manufacture, or refund the purchase price for, the products that we have
found to be defective. Failure by purchaser to give such written notice
within the 30-day time period shall be deemed an absolute and unconditional waiver of purchaser’s claim for such defects. Products repaired or
replaced shall be covered by this warranty for the remainder of the original warranty period or ninety (90) days from the date of shipment,
whichever is longer.
Warranty claims should be sent to Fantech, Inc.,
Attn: Quality Department, 10048 Industrial Blvd., Lenexa, KS 66215.
Included in the claim should be Order Number, Model Numbers, Serial
Numbers and a detailed description of the issues.
Purchaser assumes all other responsibility for any loss, damage or injury
to persons or property arising out of the use of our products, either
alone or in combination with other products or components.
Limitation of Warranty and Liability
THE SOLE AND EXCLUSIVE REMEDY FOR BREACH OF ANY WARRANTY
HEREUNDER SHALL BE LIMITED TO REPAIR, CORRECTION OR
REPLACEMENT, OR REFUND OF THE PURCHASE PRICE UNDER THE
PRECEDING PARAGRAPH ENTITLED “LIMITED WARRANTY”. FANTECH
VENTILATION PRODUCTS SHALL NOT BE LIABLE FOR DAMAGES
CAUSED BY DELAY IN PERFORMANCE AND IN NO EVENT,
REGARDLESS OF THE FORM OF THE CLAIM OR CAUSE OF ACTION,
SHALL OUR LIABILITY TO PURCHASER AND/OR ITS CUSTOMERS
EXCEED THE PRICE PAID BY PURCHASER FOR THE SPECIFIC PRODUCT
PROVIDED BY US THAT GAUE RISE TO THE CLAIM OR CAUSE OF
Warning
Fantech products are designed and manufactured to provide reliable
performance, but they are not guaranteed to be 100% free from
defects. Even reliable products will experience occasional failures and
this possibility should be recognized by the user. If these products are
ACTION. PURCHASER AGREES THAT IN NO EVENT SHALL OUR
LIABILITY TO PURCHASER AND/OR ITS CUSTOMERS EXTEND TO
INCLUDE INCIDENTAL, CONSEQUENTIAL OR PUNITIVE DAMAGES. The
term “consequential damages” shall include, but not be limited to,
loss of anticipated profits, business interruption, loss of use or revenue,
cost of capital, or loss or damage to property or equipment.
It is expressly understood that any technical advice furnished by us with
respect to the use of our products is given without charge, and we
assume no obligation or liability for the advice given, or results obtained,
all such advice being given and accepted.
used in a life support ventilation system where failure could result in loss
or injury, the user should provide adequate backup ventilation,
supplementary natural ventilation, failure alarm system, or acknowledge
willingness to accept the risk of such loss or injury.
fantech
Page 8
fantech
Fantech reserves the right to make technical changes.
For updated documentation please refer to www.fantech.net