Fairchild MOC3020M service manual

MOC301XM, MOC302XM — 6-Pin DIP Random-Phase Optoisolators Triac Driver Output (250/400 Volt Peak)
September 2009
Features
Excellent I degradation
High isolation voltage—minimum 5300 VAC RMS Underwriters Laboratory (UL) recognized—
File #E90700
Peak blocking voltage – 250V-MOC301XM – 400V-MOC302XM VDE recognized (File #94766)
– Ordering option V (e.g. MOC3023VM)
stability—IR emitting diode has low
FT
Applications
Industrial controls Solenoid/valve controls
Traffic lights Static AC power switch
Vending machines
Incandescent lamp dimmers Solid state relay
Motor control Lamp ballasts
Description
The MOC301XM and MOC302XM series are optically isolated triac driver devices. These devices contain a GaAs infrared emitting diode and a light activated silicon bilateral switch, which functions like a triac. They are designed for interfacing between electronic controls and power triacs to control resistive and inductive loads for 115 VAC operations.
Schematic Package Outlines
ANODE
CATHODE
©2005 Fairchild Semiconductor Corporation www.fairchildsemi.com MOC301XM, MOC302XM Rev. 1.0.2
1
2
3
N/C
*DO NOT CONNECT (TRIAC SUBSTRATE)
MAIN TERM.
6
NC*
5
4
MAIN TERM.
MOC301XM, MOC302XM — 6-Pin DIP Random-Phase Optoisolators Triac Driver Output (250/400 Volt Peak)
Absolute Maximum Ratings
(T
= 25°C unless otherwise noted)
A
Stresses exceeding the absolute maximum ratings may damage the device. The device may not function or be operable above the recommended operating conditions and stressing the parts to these levels is not recommended. In addition, extended exposure to stresses above the recommended operating conditions may affect device reliability. The absolute maximum ratings are stress ratings only.
Symbol Parameters Device Value Units
TOTAL DEVICE
T
STG
T
OPR
T
SOL
T
V
ISO
P
EMITTER
I
F
V P
DETECTOR
V
DRM
I
TSM
P
Storage Temperature All -40 to +150 °C Operating Temperature All -40 to +85 °C Lead Solder Temperature All 260 for 10 sec °C Junction Temperature Range All -40 to +100 °C
J
Isolation Surge Voltage
(1)
All 7500 Vac(pk)
(peak AC voltage, 60Hz, 1 sec. duration)
Total Device Power Dissipation @ 25°C Ambient
D
All 330 mW
Derate above 25°C
Continuous Forward Current All 60 mA Reverse Voltage All 3 V
R
Total Power Dissipation @ 25°C Ambient
D
Derate above 25°C
Off-State Output Terminal Voltage MOC3010M/1M/2M
MOC3020M/1M/2M/3M
Peak Repetitive Surge Current
All 100 mW
1.33 mW/°C
250 400
All 1 A
(PW = 1ms, 120pps)
Total Power Dissipation @ 25°C Ambient
D
All 300 mW
Derate above 25°C
4.4 mW/°C
V
4 mW/°C
Note:
1. Isolation surge voltage, V
, is an internal device dielectric breakdown rating. For this test, Pins 1 and 2 are
ISO
common, and Pins 4, 5 and 6 are common.
©2005 Fairchild Semiconductor Corporation www.fairchildsemi.com MOC301XM, MOC302XM Rev. 1.0.2 2
MOC301XM, MOC302XM — 6-Pin DIP Random-Phase Optoisolators Triac Driver Output (250/400 Volt Peak)
Electrical Characteristics
(T
= 25°C Unless otherwise specified)
A
Individual Component Characteristics
Symbol Parameters Test Conditions Device Min. Typ. Max. Units
EMITTER
V
Input Forward Voltage I
F
Reverse Leakage Current V
I
R
= 10mA All 1.15 1.5 V
F
= 3V, T
R
= 25°C All 0.01 100 µA
A
DETECTOR
I
DRM
V
Peak Blocking Current, Either Direction
Peak On-State Voltage,
TM
Either Direction
Rated V
I
= 100 mA peak, I
TM
DRM
, I
F
(2)
= 0
= 0 All 1.8 3 V
F
All 10 100 nA
Transfer Characteristics
Symbol DC Characteristics Test Conditions Device Min. Typ. Max. Units
I
LED Trigger Current Voltage = 3V
FT
Holding Current, Either
I
H
Direction
(3)
MOC3020M 30 mA MOC3010M 15 MOC3021M MOC3011M 10 MOC3022M MOC3012M 5 MOC3023M
All 100 µA
Notes:
2. Test voltage must be applied within dv/dt rating.
3. All devices are guaranteed to trigger at an I I
lies between max I
F
(30mA for MOC3020M, 15mA for MOC3010M and MOC3021M, 10mA for MOC3011M and
FT
value less than or equal to max I
F
MOC3022M, 5mA for MOC3012M and MOC3023M) and absolute max I
. Therefore, recommended operating
FT
(60mA).
F
©2005 Fairchild Semiconductor Corporation www.fairchildsemi.com MOC301XM, MOC302XM Rev. 1.0.2 3
Safety and Insulation Ratings
As per IEC 60747-5-2, this optocoupler is suitable for “safe electrical insulation” only within the safety limit data. Compliance with the safety ratings shall be ensured by means of protective circuits.
Symbol Parameter Min. Typ. Max. Unit
MOC301XM, MOC302XM — 6-Pin DIP Random-Phase Optoisolators Triac Driver Output (250/400 Volt Peak)
Installation Classifications per DIN VDE 0110/1.89
Ta ble 1 For Rated Main Voltage < 150Vrms I-IV For Rated Main voltage < 300Vrms I-IV Climatic Classification 55/100/21 Pollution Degree (DIN VDE 0110/1.89) 2
CTI Comparative Tracking Index 175 V
PR
Input to Output Test Voltage, Method b,
V
x 1.875 = V
IORM
, 100% Production Test
PR
1594 V
peak
with tm = 1 sec, Partial Discharge < 5pC
Input to Output Test Voltage, Method a,
V
IORM
x 1.5 = V
, Type and Sample Test
PR
1275 V
peak
with tm = 60 sec, Partial Discharge < 5pC
V
V
IORM
IOTM
Max. Working Insulation Voltage 850 V
Highest Allowable Over Voltage 6000 V
peak
peak
External Creepage 7 mm External Clearance 7 mm
Insulation Thickness 0.5 mm
RIO Insulation Resistance at Ts, V
= 500V 10
IO
9
©2005 Fairchild Semiconductor Corporation www.fairchildsemi.com MOC301XM, MOC302XM Rev. 1.0.2 4