Extron electronic MTP T AV, MTP R AV User Manual

PowerCage™ MTP T AV and MTP R AV Board
Setup Guide
The Extron® PowerCage MTP T AV and
PowerCage
MTP R AV
C
Y/VID
MONO
AUDIO OUTPUT
MTP R AV
Installation
1. Select an open slot at the rear, or take out a blank plate by loosening the two
PowerCage
MTP T AV
MTP R AV are twisted pair transmitters and receivers in a modular board format for the
INPUT
PowerCage 1600 modular enclosure. They
OUTPUT
transmit or receive composite video or S-video and audio over CAT 5-type cable.
C
Both boards can be used with any CAT 5, 5e, or 6 cable, or Extron Enhanced Skew-Free™ A/V UTP cable for cable runs up to 1000 feet (300 m). The boards mount in any of the 16 expansion slots at the rear of
Y/VID
the PowerCage 1600.
1 2
GAIN
SHARP
Refer to the PowerCage MTP T AV and MTP R AV User Guide and the
L R
PowerCage 1600 Enclosure User Guide, available at www.extron.com.
AUDIO INPUT
NOTE: The hot-swappable, modular design allows for replacing or
upgrading boards in the field at any time, without having to
MTP T AV
power down the system.
screws (top and bottom), and lifting the blank away.
NOTE: If a board is already in the slot, loosen the screws and remove the board.
2. Remove the new board from the box,
holding the board by the frame.
3. Hold the board with the signal connectors
towards you and the MTP AV board name
16 Available Single Board Slots or 8 Double Board Slots
and LED at the top, and align the top and bottom grooves of the board with the slide
PowerCage
Rx
Tx
1 2
ALARM
Tx Rx
RS-232 REMOTE
Tx Rx
AUDIO L R
RGB
OUTPUT
MTP R AV
PowerCage
INPUT
FOX 3G HD-SDI
Tx Rx
C
Y/VID
1 2
MONO
AUDIO OUTPUT
GAIN
MODE
SHARP
HD/SDI INPUT HD/SDI OUTPUTS
Screws (2 per board)
Align board and slide into slot.
PowerCage
FOX 4G RX RGB
Rx
Tx
1 2
ALARM
Tx Rx
RS-232 REMOTE
Tx Rx
RS-232 OVER FIBER
AUDIO L R
RGB
OUTPUT
posts in the selected enclosure slot.
4. Carefully slide the board into the slot,
aligning that the two tabs on the lower front end of the board with the matching ports in the enclosure. Push the board firmly into place.
5. Tighten the screws to secure the board.
Power Supply
C
LISTED
N15778
100-240V 50/60Hz
5A MAX.
PowerCage
FOX 4G RX RGB
RS-232 OVER FIBER
US
1T23 I.T.E.
6. If applicable, repeat steps 1 through 5
for any other modular boards.
NOTE: Cover all empty board slots; do not leave them open. Using a tool, securely
fasten the screws for boards and blank panels after initial installation and subsequent removal and replacement of the boards.
7. If power has been removed, reconnect and power on the PowerCage. The LED on
the board lights green and the new board is auto-detected.
8. Following the image at right, connect input or output
device cables to the the two BNC connectors for S-video signals or for composite video signals.
Continued on side 2.
Y/VID C
CY/VID
S-video
OR
Composite
Video
1
USA - West
USA - East
Europe
Asia
Japan
China
Middle Ea st
PowerCage MTP T AV and MTP R AV Board Setup Guide, cont’d
RJ-45
9. Insert a 5-pole captive screw connector into the captive screw audio input or
output connector for balanced or unbalanced stereo audio input, or mono output. Wire the connector as shown.
Do not tin the wires!
Tip
Sleeve
Tip
Sleeve
Unbalanced Stereo Input
Tip
Ring
Sleeve (s)
Tip
Ring
Balanced Stereo Input
L R
CAUTION
For unbalanced audio, connect the sleeve(s) to the ground contact.
DO NOT connect the sleeve(s) to
the negative (-) contacts.
NO Ground Here
NO Ground Here
Tip
Sleeve
Tip
Unbalanced Mono Output
Tip
Ring
Sleeve
Tip
Ring
Balanced Mono Output
NOTE: These boards do not have a jumper to set for stereo audio output.
Audio output is always mono.
10. Either connect the output RJ-45 on the
MTP T AV to an MTP receiver using CAT 5, 5e, or 6 cable; or connect the input RJ-45 on the MTP R AV board with an output cable to a suitable MTP transmitter. Terminate the cable as shown on the right, using the same standard (T568A or T568B) at both ends.
11. Image sharpness and gain (MTP R AV only) can be
adjusted with the two front panel rotary encoders
Connector
12 34 567 8
Insert Twisted Pair Wires
Pins:
Pin
1
2
3
4
5
6
7
8
for optimizing the image and signal quality. View the image and adjust the either control for the best image quality.
PowerCage Front Panel
The following PowerCage enclosure front panel features are relevant to the installation and operation of the MTP T AV and MTP R AV boards.
NOTE: The MTP T AV and MTP R AV boards are not configurable, and the
PowerCage Comm port feature does not work with the MTP boards.
T568A T568B
Wire color
White-green
Green
White-orange
Blue Blue
White-blue
Orange
White-brown
Brown
White-orange
Orange
White-green
White-blue
Green
White-brown
Brown
Wire color
a Power LED (slots 1-16) —
This LED lights to indicate that power is applied to the selected board.
1
b Temperature LED — This LED
lights if the temperature within
POWER ALARM
COMM
2 3 14 15 16
the PowerCage enclosure is high (approximately 167 °F [75 °C]) and
equipment damage is imminent.
1
For full installation and operating details of the PowerCage, refer to the PowerCage 1600 Enclosure User Guide available at www.extron.com.
Extron
Headqua rters
+800.6 33.9876
Inside USA / Canada Only
+1.714.491.1500 +1.714.491.1517 FAX
Extron
+800.6 33.9876
Inside USA / Canada Only
+1.919.863.1794 +1.919.863.1797 FA X
Extron
+800.3 987.6673
Inside Europe Only
+31.33.4 53.4040 +31.33.4 53.4050 F AX
Extron
+800.7 339.8766
Inside Asia Only
+65.63 83.440 0 +65.63 83.466 4 FAX
© 2010 Extron Electronics. All rights reserved. www.extron.com