This guide provides instructions for installing the following Extron MediaLink
Mounting Options faceplates, which are designed for use with MLC 104 IP Plus
MediaLink Controllers.
The MLM 104 L, MLM 104 2GWP, or MLM 104 4GWP faceplate is shipped
with the MLC 104 IP Plus controller, depending on the controller configuration
that is ordered. The rest of the mounting options described below may be
ordered separately as replacements, or for use with an MLC 104 IP Plus that is
ordered without a faceplate.
•MLM 104 L — A low-profile, 3.15" H x 6.50" W (8.0 cm H x 16.5 cm W)
lectern/furniture-mounting faceplate. This faceplate is required when you are
mounting an MLC 104 IP Plus using an optional UCM RAAP or UCM 10X8P
mounting kit.
Part numbers: 70-357-02 (black), 70-357-03 (white), 70-357-05 (RAL9010 white)
™
•MLM 104 LAAP — A low-profile, 3.15" H x 10.00" W (8.0 cm H x 25.40 cm W)
lectern/furniture-mounting faceplate with an opening that accommodates
four single-space AAPs
Part numbers: 70-358-02 (black), 70-358-03 (white), 70-358-05 (RAL9010 white)
68-878-01, Rev. D
08 07
1MLM 104 Faceplates • Installation Guide
MLM 104 Faceplates Installation Guide, cont’d
•MLM 104 2GWP — A two-gang (4.50" H x 4.60" W [11.43 cm H x 11.68 cm W])
faceplate that can be mounted to a mud ring (mounting bracket), an Extron
Surface Mount Box, an Extron External Wall Box, or a standard electrical box
Part numbers: 70-378-02 (black), 70-378-03 (white), 70-378-05 (RAL9010 white)
•MLM 104 4GWP — A four-gang (4.50" H x 8.23" W [11.43 cm H x 20.9 cm W])
faceplate with an opening that accommodates four single-space AAPs. It can
be mounted to a mud ring, an Extron Surface Mount Box, an Extron External
Wall Box, or a standard electrical box.
Part numbers: 70-379-02 (black), 70-379-03 (white), 70-379-05 (RAL9010 white)
•MLM 104 6GWP— A six-gang (4.50" H x 11.75" W [11.43 cm H x 29.85 cm W])
faceplate with two openings that accommodate four single-space AAPs each
(eight AAPs total). It can be mounted to a mud ring, an Extron Surface Mount
Box, an Extron External Wall Box, or a standard electrical box.
Part numbers: 70-355-02 (black), 70-355-03 (white), 70-355-05 (RAL9010 white)
MLM 104 Faceplates • Installation Guide2
Replacing the MLC 104 IP Plus Faceplate with an MLM
Faceplate
1.If your MLC controller is already installed in a wall or furniture, remove the
four screws that attach it to its mounting surface (marked
below), and lift it out.
2.After the MLC has been removed from the wall or furniture, use a small
Phillips screwdriver to remove the four faceplate attachment screws (marked
in the diagram below), and save them for later use.
b
CAUTION
Do not remove the four faceplate screws while the MLC is installed in a
wall or furniture, or the controller may fall into the wall or furniture.
in the diagram
a
1
2
DISPLAY
ON
VOLUME
OFF
2
1
CONFIG
1
VCR
1
2
DVD
PC
3
4
MLC 104 IP PLUS
1
2
2
3.Lift the faceplate off the MLC 104 IP Plus, as shown below.
VCR
FF
O
N
O
N
O
DVD
FF
O
PC
Extron
DISPLAY
VOLUME
IG
F
N
O
C
MLC 104 IP PLUS
1
2
3
4
3MLM 104 Faceplates • Installation Guide
MLM 104 Faceplates Installation Guide, cont’d
4.Align the openings in the new MLM faceplate with the controller’s buttons,
knob, and LEDs, then place the new faceplate on the MLC 104 IP Plus.
5.Replace the four screws removed in step 2, and hand tighten them.
6.Install the MLC 104 IP Plus controller in a wall or furniture as appropriate.
Templates
Use one of the following templates as a guide to measure and mark the hole for
installing the MLM 104 faceplate with an attached MLC 104 IP Plus. (Refer to your
MLC 104 IP User’s Manual for instructions on preparing the mounting site.)
CAUTION
The MLC controller requires a depth of at least 2.0" (5.1 cm) inside the wall or
furniture.
These templates are not to scale. Use the dimensions shown in the
templates as reference guidelines for measuring and drawing the rectangle
that will be cut out.
MLM 104 Faceplates • Installation Guide4
MLM 104 L and MLC 104 IP Plus L template
3.15"
(8.0 cm)
2.8"
(7.1 cm)
SURFACE CUT-OUT AREA
FOR FURNITURE MOUNT
6.5"
(16.5 cm)
3.5"
(8.9 cm)
Top Panel
Location of
MLC 104 IP Plus
.295" (0.75 cm)
TEMPLATE IS NOT FULL SIZE.
Cut-Out Template for Extron's MLM 104 L
and MLC 104 IP Plus L
To install MLC 104 IP Plus
and MLM 104 L
directly into furniture,
cut along this line.
.250" (0.64 cm)
5MLM 104 Faceplates • Installation Guide
MLM 104 Faceplates Installation Guide, cont’d
MLM 104 LAAP template
3.15"
(8.0 cm)
2.8"
(7.1 cm)
Top Panel
10"
(25.4 cm)
7.9"
(20.1 cm)
SURFACE CUT-OUT
AREA FOR
FURNITURE MOUNT
Location of MLC 104 IP Plus
To install the MLC 104 IP Plus
and the MLM 104 LAAP
directly into furniture,
cut along this line.
.250" (0.64 cm)
.295" (0.75 cm)
TEMPLATE IS NOT FULL SIZE.
Cut-Out Template for Extron's MLM 104 LAAP
MLM 104 Faceplates • Installation Guide6
MLM 104 2GWP and MLC 104 IP Plus template
4.5"
(11.4 cm)
2.8"
(7.1 cm)
SURFACE CUT-OUT AREA
4.6"
(11.7 cm)
FOR FURNITURE MOUNT
3.5"
(8.9 cm)
Top Panel
Location of MLC 104 IP Plus
TEMPLATE IS NOT FULL SIZE.
Cut-Out Template for Extron's MLM 104 2GWP
and MLC 104 IP Plus
To install MLC 104 IP Plus
and MLM 104 2GWP
directly into furniture,
cut along this line.
7MLM 104 Faceplates • Installation Guide
MLM 104 Faceplates Installation Guide, cont’d
MLM 104 4GWP and MLC 104 IP Plus AAP template
4.5"
(11.4 cm)
2.8"
(7.1 cm)
Top Panel
8.23"
(20.9 cm)
7.1"
(18.0 cm)
SURFACE CUT-OUT
AREA FOR
FURNITURE MOUNT
TEMPLATE IS NOT FULL SIZE.
Cut-Out Template for Extron's MLM 104 4GWP
and MLC 104 IP Plus AAP
Location of MLC 104 IP Plus
To install the MLC 104 IP Plus
and the MLM 104 4GWP
directly into furniture,
cut along this line.
MLM 104 Faceplates • Installation Guide8
MLM 104 6GWP template
4.5"
(11.4 cm)
2.8"
(7.1 cm)
Top Panel
11.752"
(29.85 cm)
Location of MLC 104 IP Plus
11.0"
(27.9 cm)
SURFACE CUT-OUT
AREA FOR
FURNITURE MOUNT
To install the MLC 104 IP Plus
and the MLM 104 6GWP
directly into furniture,
cut along this line.