User’s Manual
FF 120T
Flat Field Speaker
1 Power down
Power down all attached devices before proceeding.
2 Suspended ceiling installation
Remove the ceiling tile where the FF 120T speaker will be
installed. Cut out a 12" section of the tile from either end
where the speaker will be installed, as shown below.
End Section
12”
2’
4’
Draw Lines
24” x 48” Ceiling Tile 24” x 24” Ceiling Tile
Cut Material
12”
2’
2’
3 Remove the terminal cover plate
Loosen the two screws (do not remove) on the top terminal
cover plate and remove the cover plate.
• If a 70 V/100 V line distribution amplifier is being used,
such as the Extron XPA 2001-70V or XPA 2001-100V, the
cover plate is no longer needed since the included CPX 120
transformer cover plate will be installed in its place.
• If the 70 V/100 V line distribution system is not being
installed, retain the cover plate and proceed to step 6b.
4 Routing cables through the
CPX 120 cover plate
The CPX 120 cover plates mount to the speakers with
the transformer side down. See the illustration below.
Flexible
Conduit
Flexible Conduit
Adapter
or or
Seismic Anchor
Ring
Top Terminal
Cover
N Installation of conduit and conduit adapters should
conform to all applicable building codes and local
ordinances.
68-1450-02 Rev. A
07 09
From Amp
Locking Ring
See the NOTES below.
To Second Speaker
Cable Clamp
Adapter (supplied)
5 Connecting wires to the CPX 120
terminal block
The transformer side of the CPX 120 cover plate has a
7-connector terminal block. Route the two wires from the
amplifier through the cover plate hole to the transformer side.
The black negative (-) wire attaches to the “COM” terminal,
and the red postitive (+) wire attaches to the desired terminal
tap.
70 V
COM NC 16 W 8 W 4 W 2 W 1 W
100 V
N Installation in a plenum-rated environment
requires a wire gauge of 12 AWG to 18 AWG.
Pull the speaker wires from the conduit if a conduit is used.
Strip 3/16" (5 mm) from the wire ends, keep the wire end
strands together by twisting them (do not tin the wires), and
secure the wires to the appropriate taps on the terminal
block’s captive screw connectors as indicated on the tap
label. Use a small flat blade screwdriver to tighten the
terminal block screws. See the note below for wiring
additional speakers.
N Route the speaker wires from the second speaker
through the cover plate hole to the transformer
side and twist the black negative (-) wires together
and twist the red positive (+) wires together before
inserting them into the terminal block. Additional
speakers can be daisy chained this way.
N Be sure to observe the 70 V or 100 V system
designation as indicated on the label.
N Wiring two speakers in parallel requires that the
maximum wire gauge not exceed 16 AWG. In a
single speaker installation the wire gauge should
not exceed 12 AWG.
When using flexible conduit, insert the conduit into the cover
plate opening using an appropriate conduit adapter and
secure the conduit to the plate as shown in the following
illustration.
1 W
2 W4 W8 W16 WCOM
2 W4 W8 W16 WCOM
70 V
COM NC 16 W 8 W 4 W 2 W 1 W
100 V
NC
NC
1 W
1
FF 120T
User’s Manual
(Red) To Speaker
(+) Terminal
NC
1 W
2 W4 W8 W16 WCOM
70 V
COM NC 16 W 8 W 4 W 2 W 1 W
100 V
When using plenum speaker wire without a conduit, insert
the wire through the cable clamp adapter (included) and
secure the adapter to the cover plate.
• If a seismic support line is being used, install the seismic
anchor ring (included) between the conduit adapter and
the CPX 120 cover plate as shown below.
• If the CPX 120 transformer cover plate is being installed,
proceed to step 6a, otherwise proceed to step 6b.
Flat Field Speaker
(Black) To Speaker
(-) Terminal
Black (-)
To Second
Speaker
Red (+)
Black (-)
From Amplifier
(70V/100V)
Red (+)
6b Connecting wires from a low
impedance amplifier to the
speaker
Route the wires from the amplifier to the speaker using the
same procedure for routing speaker wire (and conduit if
applicable) through the cover plate as described in step 3.
Strip 3/16" (5 mm) from the ends of the two speaker wire
leads (+ and -) coming from the amplifier. Keep the
wire strands together by twisting them (do not tin the wires),
and secure the wires to the speaker’s input terminals while
observing the correct polarity.
Connect the red positive (+) wire to the + speaker terminal
and connect the black negative (-) wire to the - speaker
terminal depending on whether one or two speakers are
being connected, as shown below.
Red Wire
To Amplifier
Black Wire
6a Connecting wires from the
CPX 120 to the speaker
Strip 3/16" (5 mm) from the ends of the two speaker wire
leads (+ and -) coming from the transformer. Keep the
wire strands together by twisting them (do not tin the wires),
and secure the wires to the speaker’s input terminals while
observing the correct polarity.
Connect the red positive (+) wire to the + speaker terminal
and connect the black negative (-) wire to the - speaker
terminal as shown below. Proceed to step 7.
Seismic Anchor Ring
Red Wire
To CPX 120 transformer
cover plate
Black Wire
One Speaker
Two Speakers
Red Wire
To Amplifier
To Second Speaker
To Amplifier
To Second Speaker
Black Wire
2