Extech CT100 Operating Manual

User Guide
CT100 Network Cable Tester
Introduction
Congratulations on your purchase of the Extech CT100 Network Cable Tester System. The system consists of a Transmitter and a Receiver. This system automatically performs the following tests: Continuity, Open/Short Circuits, and Wire Crosses (Reversals). The CT100 tests “F” type coaxial and RJ45 terminated cables meeting the following wiring standards:
10Base-T
EIA/TIA 568B
AT&T258A
Token Ring
Operation
WARNING: Do NOT test on LIVE CIRCUITS
1. Power the transmitter by moving the ON/OFF switch to the ON position. The power LED will light.
2. To test a patch cable, connect one end of the cable under test to the Transmitter and the other
end to the Receiver. Testing begins automatically and is indicated by the stepping action of the LEDs on the Receiver. (Note: To test cabling that is part of an installation, the Transmitter and Receiver must be connected in line with the installation. Patch-cords needed to connect from wall-plates to the Transmitter and Receiver must be provided by the user.)
3. Test result examples are listed below:
EIA/TIA 568A
PR2
PR3 PR1 PR4
1 2 3 4 5 6 7 8
4 Pair Test Pass = Green x 4 Fail = Red or No Light
10Base-T
PR2
PR1
1 2 3 4 5 6 7 8
2 Pair Test (1-2 and 3-6) Pass = Green x 2 Fail = Red or No Light
EIA/TIA 568B
PR3
4 Pair Test Pass = Green x 4 Fail = Red or No Light
(AT&T 258A)
PR2 PR1 PR4
1 2 3 4 5 6 7 8
Screened (Shielded)
Cable
PR3 PR1 PR4
1 2 3 4 5 6 7 8
PR2
4 Pair + Shield Test Pass = Green x 5 Fail = Red or No Light
Token Ring
PR2
PR1
1 2 3 4 5 6 7 8
Coax
2 Pair Test (3-6 and 4-5) Pass = Green x 2 Fail = Red or No Light
Pass = Green x 1 Fail = Red or No Light
Battery Replacement (Transmitter only)
1. Turn power OFF on the Transmitter, disconnect any cables, and remove the Transmitter’s rear screw to access the battery compartment. (The
Receiver does not contain batteries).
2. Replace the two ‘AAA’ 1.5V batteries and re-assemble the Transmitter.
Warranty
EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and workmanship for one year from date of shipment (a six month limited warranty applies on sensors and cables). If it should become necessary to return the instrument for service during or beyond the warranty period, contact the Customer Service Department at (781) 890-7440 ext. 210 for authorization or visit our website at www.extech.com (click on ‘Contact Extech’ and go to ‘Service Department’ to request an RA number). A Return Authorization (RA) number must be issued before any product is returned to Extech. The sender is responsible for shipping charges, freight, insurance and proper packaging to prevent damage in transit. This warranty does not apply to defects resulting from action of the user such as misuse, improper wiring, operation outside of specification, improper maintenance or repair, or unauthorized modification. Extech specifically disclaims any implied warranties or merchantability or fitness for a specific purpose and will not be liable for any direct, indirect, incidental or consequential damages. Extech's total liability is limited to repair or replacement of the product. The warranty set forth above is inclusive and no other warranty, whether written or oral, is expressed or implied.
All rights reserved including the right of reproduction in whole or in part in any form.
Copyright © 2002 Extech Instruments Corporation.
Website: www.extech.com
Email: support@extech.com Rev 1.0 9/02