Extech CO10 Operating Manual

User's Guide
Carbon Monoxide Meter Model CO10
Introduction
Congratulations on your purchase of the Extech C010 Carbon Monoxide Meter. The CO10 measures and displays CO concentrations between 0 and 1000 parts per million (ppm).
Safety Information
Carbon monoxide is life threatening even at relatively low concentrations; learn and recognize the effects of CO poisoning (see Table below). Do not use this meter as a personal safety monitoring device.
Effects of CO poisoning
0-1 PPM Normal background levels
9 PPM Maximum indoor air quality level
50 PPM Maximum 8 hour average exposure level
200 PPM Mild headache, fatigue, nausea and dizziness
400 PPM Frontal headache, life threatening after 3 hours 800 PPM Dizziness, nausea, convulsions, DEATH WITHIN 2 TO 3 HOURS 1600 PPM Nausea within 20 minutes, DEATH WITHIN 1 HOUR 12800 PPM DEATH WITHIN 2 TO 3 MINUTES
Ensure that the meter is turned on in an area free of CO. If not, the meter will read incorrectly when subsequently measuring CO.
Meter Description
1. LCD display
2. Power ON/OFF key
3. MODE key
4. Power on/Alarm light
5. SEL key
6. Sensor
7. Battery compartment