Excalibur 40-125 User Manual

SETUP & OPERATION MANUAL
FEATURES
Router lift for Excalibur cast-iron tables #40-070 and #40-075, MDF tables #40-047 and #40-049 & phenolic tables #40-043 and #40-045.
Heavy-duty massive router lift with 9 ¼x 11
¾aluminum top plate.
Stable 4 post/lift screw design & chain drive lifting system controlling all 4 corners simul­taneously.
ROUTER LIFT
for Excalibur router tables
MODEL
#40-125
JANUARY 03/13 © Copyright General® International 01/2013
GENERAL® INTERNATIONAL
8360 Champ-d’Eau, Montreal (Quebec) Canada H1P 1Y3
Telephone (514) 326-1161 • Fax (514) 326-5555 • www.general.ca
THANK YOU for choosing this Excalibur by General
®
International model #40-125 Router Lift. This router lift has been carefully tested and inspected before shipment and if properly used and maintained, will provide you with years of reliable service. For your safety, as well as to ensure optimum performance and trouble-free operation,and to get the most from your investment, please take the time to read this manual before assembling, installing and operating the unit.
The manual’s purpose is to familiarize you with the safe operation, basic function, and features of this router lift as well as the set-up, maintenance and identification of its parts and compo­nents. This manual is not intended as a substitute for formal woodworking instruction, nor to offer the user instruction in the craft of woodworking. If you are not sure about the safety of performing a certain operation or procedure, do not proceed until you can confirm, from knowledgeable and qualified sources, that it is safe to do so.
Once you’ve read through these instructions, keep this manual handy for future reference.
Disclaimer: The information and specifications in this manual pertain to the unit as it was supplied from the factory at the time of printing. Because we are commit­ted to making constant improvements, General International reserves the right to make changes to components, parts or features of this unit as deemed necessary,without prior notice and without obligation to install any such changes on previously delivered units. Reasonable care is taken at the factory to ensure that the specifications and information in this manual corres-
ponds with that of the unit with which it was supplied. However, special orders and “after factory” modifica­tions may render some or all information in this manual
®
inapplicable to your machine. Further, as several gene­rations of this model of router lift and several versions of this manual may be in circulation, if you own an earlier or later version of this unit, this manual may not depict your machine exactly. If you have any doubts or ques­tions contact your retailer or our support line with the model and serial number of your unit for clarification.
GENERAL®& GENERAL®INTERNATIONAL WARRANTY
ll component parts of General®, General® International and Excalibur by General
A International ® products are carefully inspected during all stages of production and each unit is thoroughly inspected upon completion of assembly.
Limited Lifetime Warranty
Because of our commitment to quality and customer satisfaction, General® and General® International agree to repair or replace any part or component which upon examination, proves to be defective in either workmanship or material to the original purchaser for the life of the tool. However, the Limited Lifetime Warranty does not cover any product used for profes-
sional or commercial production purposes nor for industrial or educational applications. Such cases are covered by our Standard 2-year Limited Warranty only. The Limited Lifetime Warranty is also subject to the “Conditions and Exceptions” as listed below.
Standard 2-Year Limited Warranty
All products not covered by our lifetime warranty including products used in commercial, industrial and educational applications are warranted for a period of 2 years (24 months) from the date of purchase. General® and General® International agree to repair or replace any part or component which upon examination, proves to be defective in either workmanship or material to the original purchaser during this 2-year warranty period,subject to the“conditions and exceptions” as listed below.
To file a Claim
To file a claim under our Standard 2-year Limited Warranty or under our Limited Lifetime Warranty, all defective parts, components or machinery must be returned freight or postage prepaid to General® International, or to a nearby distributor, repair center or other location designated by General® International. For further details call our service department at 1-888­949-1161 or your local distributor for assistance when filing your claim.
Along with the return of the product being claimed for warranty, a copy of the original proof of purchase and a “letter of claim” must be included (a warranty claim form can also be used and can be obtained, upon request, from General® International or an authorized distributor) clearly stating the model and serial number of the unit (if applicable) and including an expla­nation of the complaint or presumed defect in material or workmanship.
CONDITIONS AND EXCEPTIONS:
This coverage is extended to the original purchaser only. Prior warranty registration is not required but documented proof of purchase i.e. a copy of original sales invoice or receipt showing the date and location of the purchase as well as the purchase price paid, must be provided at the time of claim.
Warranty does not include failures, breakage or defects deemed after inspection by General® or General® International to have been directly or indirectly caused by or resulting from; improper use, or lack of or improper maintenance, misuse or abuse, negligence, accidents, damage in handling or transport, or normal wear and tear of any generally considered con­sumable parts or components.
Repairs made without the written consent of General® Internationallwill void all warranty.
Rules for Safe Operation
To help ensure safe operation, please take a moment to learn the machine’s applications and limita­tions, as well as potential hazards. GENERAL® INTERNATIONAL disclaims any real or implied war­ranty and holds itself harmless for any injury that may result from improper use of its equipment.
. Make sure that the operator has been properly
1
trained and has read and understands the Owner’s Manual before operating any machinery.
2. Be sure to read, understand and follow all instructions,
warnings and safety guidelines supplied with your router.
3. Do not operate this router table when tired, distracted,
or under the effects of drugs, alcohol or any medica­tion that impairs reflexes or alertness.
4. Keep the work area well lit, clean and free of debris.
3. Secure the table to a work surface and never stand or
1
lean on it. Serious injury could occur if the table is tipped or if unintentional contact is made with spin­ning router bit.
14. Keep all guards and safety devices in place and in
good working order. If a guard must be removed for maintenance or cleaning make sure it is properly re­installed before using the machine again.
15. Hold the workpiece firmly against the table and use
suitable support if the workpiece does not have a flat surface.
5. Stay Alert! Give your work your undivided attention.
Even a momentary distraction can lead to serious injury.
6. Do not wear loose clothing, gloves, bracelets, neck-
laces, or other jewelry. Wear face, eye, ear, respiratory and body protection devices. Wear protective hair covering to contain long hair and wear non-slip footwear.
7. Keep hands and other body parts well away from bits
or cutting tools. When working close to the cutting tool, always use a feather board or push-stick to hold or guide the workpiece. Do not clear chips and sawdust away with hands. Use a brush.
8. Fine particulate dust is a carcinogen that can be haz-
ardous to health. Always work in a well ventilated area and whenever possible use a dust collector to mini­mize health hazards.
9. Be sure the router is running up to speed before feed-
ing the workpiece.
10. Use a suitable support if stock does not have a flat
surface.
11. Keep children and visitors at a safe distance when the
router is in operation – do not permit them to operate the router and table.
16. Feed the stock into the bit against the rotation direc-
tion of the bit. Never run the stock between the fence and the bit.
17. Do not operate with a damaged bit in the router.
18. Always disconnect the router from the power source
before changing accessories or before performing any maintenance and adjustments or if the machine will be left unattended.
19. Be sure that all adjustment tools, wrenches or other
clutter are removed from the table surface and safely stored before routing.
20. Make sure the routers switch is in the “OFF” position
before plugging in to a power source.
21. Avoid working from awkward or off balance positions.
Do not overreach and always keep both feet firmly on the floor.
22. Never leave the router unattended while running or
with the power on.
23. Do not use this router table for any purpose other than
its intended use. If used for other purposes, GENERAL® INTERNATIONAL disclaims any real or implied warranty and holds itself harmless for any injury which may result from such use.
12. Childproof and tamper proof your shop and all
machinery with locks, master electrical switches and switch keys, to prevent unauthorized or unsupervised use.
4
IDENTIFICATION OF MAIN PARTS AND COMPONENTS
A- CLAMPING BOLT B- CLAMPING BRACKET C- CHAIN D- INSERT RING WRENCH
UNDERSIDE VIEW
A
E- STARTING PIN F- CRANK HANDLE G- POSTS/SCREWS H- LOCK NUT
F
C
B
D
G
E
G
G
H
G
UNPACKING
Carefully unpack and remove the router lift and its components from the box and check for damaged or missing items as per the list of con­tents below.
NOTE: Please report any damaged or missing items to your General International distributor immediate­ly.
LIST OF CONTENTS QTY
a- ROUTER LIFT . . . . . . . . . . . . . . . . . . . . . . . . . . .1
b- ROUTER LIFT CRANK HANDLE . . . . . . . . . . . . .1
c- INSERT RING WRENCH . . . . . . . . . . . . . . . . . . .1
d- STARTER PIN . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
e- HEX SOCKET HEAD BOLT . . . . . . . . . . . . . . . . . .2
f- 2.5 MM ALLEN KEY . . . . . . . . . . . . . . . . . . . . . .1
g- 3 MM ALLEN KEY . . . . . . . . . . . . . . . . . . . . . . .1
h- 4 MM ALLEN KEY . . . . . . . . . . . . . . . . . . . . . . .1
i- 6 MM ALLEN KEY . . . . . . . . . . . . . . . . . . . . . . .1
a
c
b
d
e
f g
h
i
5
ASSEMBLY INSTRUCTIONS -
SERIOUS PERSONAL INJURY COULD OCCUR IF YOU CONNECT THE MACHINE TO THE POWER SOURCE BEFORE YOU HAVE COM-
LETED THE INSTALLATION AND ASSEMBLY STEPS. DO NOT CONNECT THE MACHINE TO THE POWER SOURCE UNTIL INSTRUCTED
P TO DO SO.
* Excalibur Router Tables. Note regarding installation on shop-made or non-Excalibur router tables: Before constructing your own table top, take note
that Excalibur does not use leveler set screws in their router plates or lifts. Instead each Excalibur router table includes it’s own built-in leveling system. The reason for this is that on shop-made table tops made of wood or MDF, metal set screw lev­elers in the router plate will eventually sink into the softer material of the table and become ineffective. If you are installing this router lift in a shop made router table or on another brand of router table that does not include a built-in levelling sytem PLEASE SEE/USE THE EXCALIBUR #40-092 LEVELER BAR KIT DESIGNED SPECIFICALLY FOR USE WITH SHOP-
MADE TABLE TOPS.
Note: Model #40-075 for 40-200C Cast-iron table shown. The following steps apply to all Excalibur router table options.
PREPARE THE TABLE * FOR ROUTER LIFT
1. Place the router lift into the opening in the table.
3. From the underside of the table, adjust the 4 phillips
head screws in the corners A - up or down until the plate is flat and level with the table surface.
Note: While tightening the lock nut, make sure that the
adjuster screw does not turn. Confirm by re-checking
the leveling of the lift and table surface.
2. Use a straightedge to test the plate for level with the
table top.
A
4. Remove the lift and lock the adjuster screw in place by turning the lock nut A clockwise (tighten).
5. After the four corners are set, proceed to set the remaining 6 leveler screws and lock them in place.
6
ASSEMBLY INSTRUCTIONS -
SERIOUS PERSONAL INJURY COULD OCCUR IF YOU CONNECT THE MACHINE TO THE POWER SOURCE BEFORE YOU HAVE COM-
LETED THE INSTALLATION AND ASSEMBLY STEPS. DO NOT CONNECT THE MACHINE TO THE POWER SOURCE UNTIL INSTRUCTED
P TO DO SO.
MOUNTING A ROUTER
This model 40-125 “fixed base” router lift, A is designed to
ccommodate the largest diameter router motor body
a currently available.
Note: Based on our research this is the Porter Cable model 7518 and 7519 router motors which measure 4.200” in diam­eter.
All other motors (smaller diameters) will require a shim C (item # 40-626, available from you local General Interna­tional dealer), or a reducer collar such as our model 40­312 (for 3 1/2” motors) or 40-314 (for 3 1/4” motors), B, to center the router as well as prevent from overtightening the clamping system.
E
D
B
C
A
G
F
Note: The factory installed adjusting screw on the Milwau­kee motor must be lined up and inserted into the hole D located in our clamping bracket E.
H
CLOSE UP VIEW
I
1. Insert the crank handle in the black hole sur­rounded by digits as shown in H.
2. To raise the lifting carriage on the router lift to the highest or maximum upward position, turn the crank handle clockwise.
Clean packing lubricant from the lift posts/screws F and the chain G. Clean it by spraying with a solvant which will dilute the grease, and then wipe clean or use compressed air to “blow dry”. After degreasing, reapply some dry lubricant.
3. Remove the crank handle, and flip the lift over in
the table.
7
D
B
C
D
A
4. Turn Allan cap screw A counter clockwise to loosen clamp body B. The two threaded nuts C are there to help spread the clamp body.
Note: Spread clamping mechanism only as needed. Nuts
C have no other purpose and you will notice that they are
locked together and will sit in a neutral position when the router motor is secured into place.
E
Note: Some motors have pins or protrusions E on the housing.You will need to turn/twist the motor as you slide it into the clamping area, or onto the reducer collar.
E
E
Note: When mounting the Milwaukee model 5625/5626 motor, please ensure that a shim D is between the router and the clamping surface of the lift.
5. Slide the router motor into the clamping area as
shown above using shim or reducers if necessary.
F
G
For installation with reducer collar
1. Install the collar onto the router as shown in F, and then fit the router with collar into the lift, G, making sure that the collar flange sits flush against the clamping bracket.
H
Close but not touching
2. Adjust the height of the router in the collar H to
ensure that the router is as close as possible to the underside of the plate without touching I.
8
tighten
J
I
3. With the router in position, tighten clamping bolt J
securely, using a using a 8 mm Allen key, but do not over tighten. Important
: Test that the router is se­curely clamped in the reducer collar by trying to twist the router in the collar by hand.
LEVELING AND LOCKING THE ROUTER PLATE
4. The routers collet should now be protruding out from
the top plate. This will facilitate tool (router bit) changing from above the table eliminating the need to remove the router lift system from the table to access the collet.
A
1. Using a straightedge check that the router plate is level with the main table, A.
2. Adjust the 10 leveling screws B in the table opening as needed to level the plate on all four sides. (If needed, refer back to the instructions on page 6.)
B
INSERT RING REMOVAL
A
C
3. Withthe router plate leveled to thetable,lock the plate in place using the two supplied hex socket head screws C in the threaded holes on both sides of the plate.
INSTALLING THE STARTING PIN
B
A
Insert the two pins of the wrench in the two holes on the insert ring then turn clockwise to unlock the ring, A and lift the insert ring up and out of the table inser­tion, B.
Install the starting pin A into the threaded hole on the router plate as shown. The starting pin can be used as needed for freehand or template routing only.
9
TENSIONING THE DRIVE CHAIN
Proper tension on the drive chain helps maintain tool bit height in the lift without the need for a locking mechanism. If you experience problems with tool creep it may be a sign that tension on the chain needs to be tightened. If so proceed as follows:
Fig. 1 Fig. 2
CLOSE UP VIEW
A
1. Lower the lift to its lowest position and then remove
it from the table.
2. Using a 6 mm allen key loosen the cap screw A (Fig.1).
C
3. Push the sprocket assembly B (Fig.2) further along
4. While holding the sprocket assembly in position,
Note: To avoid unnecessary adjustments, make sure that the tool creep you are experiencing is not being cause by the router slipping in the reducer collar or in the clamping mechanism on the lift.
CLOSE UP VIEW
B
its slotted opening C (Fig.1) by hand to add tension to the chain.
tighten the cap screw to secure it in place.
RECOMMENDED OPTIONAL ACCESSORIES
Here are some of the optional accessories available from your local General International dealer.
For more information about our products, please visit our website at www.general.ca
4 PC ZERO CLEARANCE INSERT RING SET #40-074
For Excalibur 9 ¼x 11 ¾router plates
REDUCER COLLAR FOR EXCALIBUR MODEL 40-125 ROUTER LIFT
#40-312
Fits 3 ½diameter
routers
4 PC INSERT RING SET #40-076
¼, ½, 2 ½& 1 (30 mm for #40-099)
REDUCER COLLAR FOR EXCALIBUR MODEL 40-125 ROUTER LIFT
#40-314
Fits 3 ¼diameter
routers
10
19
8
30
8A
24
8B
25
25
29
13
40
14
1
22
3
5
22
5
22
5
2
32
27
20
12
29
12
27
26
12
10
9
29
32
20
12
26
20
11
20
26
27
36
36
16
38
16
38
15
15
35
18
21
18
15
33
15
33
6
39
7
31
37
34
4
28
17
23
26
27
Router lift
#40-125)
(
11
ARTS LIST – #40-125
P
PART NO. REF. N0. DESCRIPTION SPECIFICATIONS QTY
40125-01 60800001A ALUMINUM CARRIAGE BRACKET 1
40125-02 60500002 MAIN GEAR SHAFT 1 40125-03 60500003 LEAD SCREW 4 40125-04 60100017 INSERT RING 1-1/2” 1 40125-05 60500005 GEAR SHAFT 4 40125-06 60800021 CARRIAGE PLATE 4 40125-07 60800004 CLAMP POST 1 40125-08 60800007A TOP PLATE 1 40125-08A 60700031 STARTING PIN 1 40125-08B 906M06025 PHILLIPS HEAD SCREW M6 X 25 1 40125-09 60500009 CAM GEAR 1 40125-10 60700010 ELLIPTICAL WHEEL 1 40125-11 912M14000 NYLON NUT M14 1 40125-12 60500012 GEAR SPROCKET 5 40125-13 60700017 LOCK GUIDE NUT 1 40125-14 60700002 UPPER GUIDE NUT BASE 1 40125-15 914M061301 FLAT WASHER M6 8 40125-16 9140381902 FLAT WASHER M10 3 40125-17 60700009 LIFT CRANK HANDLE 1 40125-18 60800005 SLEEVE 3 40125-19 60800018 SCALE PLATE 1 40125-20 908M06006 SET SCREW M6 X 69 40125-21 60800002 BUSHING 4 40125-22 9236805Z0 BEARING 6805ZZ 5 40125-23 901M08020 CAP SCREW M8 X 20 1 40125-24 903M06018 FLAT HEX SOCKET HEAD SCREW M6 X 18 8 40125-25 903M04012 FLAT HEX SOCKET HEAD SCREW M4 X 12 2 40125-26 9180404018A KEY M4 X 4 X 12 5 40125-27 9236804Z0 BEARING 6804ZZ 5 40125-28 60700009B CRANK HANDLE SLEEVE 1 40125-29 9236900Z0 BEARING 6900ZZ 3 40125-30 903M06030 FLAT HEX SOCKET HEAD SCREW M6 X 30 2 40125-31 60800020 CHAIN 1 40125-32 919S01000 C-RING S10 2 40125-33 912M06000 NYLON NUT M6 4 40125-34 60100018 INSERT WRENCH 1 40125-35 60800003 BACK LASH LOCK 1 40125-36 901M10070A CAP SCREW M10 X 70 3 40125-37 910M10005 HEX NUT M10 2 40125-38 901M06060A CAP SCREW M6 X 60 4 40125-39 901M10055 CAP SCREW M10 X 55 1 40125-40 94300002 O-RING 12.42 X 1.78 1
NOTES:
12
NOTES:
13
MODEL 40-125
8360 Champ-d’Eau, Montreal (Quebec) Canada H1P 1Y3
Tel.: (514) 326-1161
Fax: (514) 326-5565 -
Parts & Service / Fax: (514) 326-5555 - Order Desk
orderdesk@general.ca
www.general.ca
IMPORTANT
When ordering replacement parts, always give the model number, serial number of the machine and
part number. Also a brief description of each item and quantity desired.
Loading...