80 PLUS Verification and Testing Report
TYPICAL EFFICIENCY (50% Load):
9-4.5 Amps
60/50 Hz
650 Watts
Note: All measurements were taken with input voltage at 115 V nominal at 60 Hz. Input AC Current Waveform (ITHD = 14.1%, 50% Load)
0.69 0.96 15.82% 10% 76.70 12.18/0.02 3.35/1.28 4.97/1.28 5.09/0.24 65.70 85.66%
1.30 0.97 17.54% 20% 146.00 12.18/0.05 3.35/2.56 4.94/2.55 5.05/0.49 131.36 89.97%
3.20 0.98 14.10% 50% 360.10 12.18/0.12 3.36/6.39 4.81/6.34 4.91/1.22 327.13 90.84%
6.51 0.99 11.22% 100% 739.90 12.19/0.24 3.38/12.8 4.62/12.65 4.69/2.45 649.37 87.76%
12V (cumulative of 12V1, 12V2, etc.)
DC Terminal Voltage (V)/ DC Load Current (A)
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
0% 25% 50% 75% 100% 125%
Efficiency (%)
Loading (% of Rated Output Power)
Efficiency of the Power Supply
Efficiency
Input Watts
Output Watts
0
100
200
300
400
500
600
700
800
20% 50% 100%
Power (Watts)
Loading (% of Rated Output Power)
Input and Output Power
These tests were conducted by a third party independent testing firm on behalf of the
80 PLUS Program. 80 PLUS is a certification program to promote highly-efficient
power supplies (greater than 80% efficiency in the active mode) in technology
applications. http://www.80plus.org/
-60.0
-40.0
-20.0
0.0
20.0
40.0
60.0
-200
-100
0
100
200
-0.001 0.003 0.008 0.013
Current (A)
Voltage (V)
Time (s)
Input Current and Voltage Waveforms
Voltage Current