Please read this manual first for correct installation and operation. This manual should be retained for future
reference. The information in this manual was current when published. The manufacturer reserves the right
to revise and improve its products. All specifications are therefore subject to change without notice.
PRECAUTIONS
1. Do not install the camera near electric or magnetic fields.
Install the camera away from TV/radio transmitters, magnets, electric motors, transformers and audio
speakers since the electromagnetic fields generated from these devices may distort the video image or
otherwise interfere with camera operation.
2. Never disassemble the camera beyond the recommendations in this manual nor introduce
materials other than those recommended herein. Improper disassembly or introduction of
corrosive materials may result in equipment failure or other damage.
3. Try to avoid facing the camera toward the sun.
In some circumstances, direct sunlight may cause permanent damage to the sensor and/or internal
circuits, as well as creating unbalanced illumination beyond the capability of the camera to
compensate.
4. Keep the power cord away from water and other liquids and never touch the power cord with
wet hands. Touching a wet power cord with your hands or touching the power cord with wet hands
may result in electric shock.
5. Never install the camera in areas exposed to oil, gas or solvents.
Oil, gas or solvents may result in equipment failure, electric shock or, in extreme cases, fire.
Page 2
6. Cleaning
For cameras with interchangeable lenses, do not touch the surface of the sensor directly with the
hands. Use lens tissue or a cotton tipped applicator and ethanol to clean the sensor and the camera
lens. Use a damp soft cloth to remove any dirt from the camera body. Please do not use complex
solvents, corrosive or abrasive agents for cleaning of any part of the camera.
7. Do not operate the camera beyond the specified temperature, humidity or power source ratings.
This camera is suitable for indoor operation only. Use the camera at temperatures within
-10°C~50°C (14°F~122°F) and humidity between 20%~ 80%; this device is not rated as submersible.
The input power source is 12VDC. Be sure to connect the proper + / - polarity and voltage, as
incorrect polarity or too high a voltage will likely cause the camera to fail, and such damage is
not covered by the warranty. The use of properly fused or Class 2 power limited type supplies is
highly recommended.
8. Mounting
Use care in selecting a solid mounting surface which will support the weight of the camera plus any
wind, snow, ice or other loading, and securely attach the camera to the mounting surface using screws
and anchors which will properly support the camera. If necessary (e.g. when mounting to drop ceilings)
use a safety wire to provide additional support for the camera.
OVERVIEW
The ECMD200 is a working PIR motion detector with a hidden color camera which utilizes a
Sony 1/3” Super HAD II CCD Sensor and advanced DSP solution for excellent light
sensitivity. providing well defined color and B/W video for surveillance applications. The
PIR sensor can be connected to an alarm system, light control, recording device or other
application. The camera is concealed within the device and enables surveillance of the
monitored area without reveling the fact that the area is under camera surveillance. The two
security systems combine to give improved protection in the desired area. A stylish design
combined with low current consumption delivers an excellent combination of intrusion
detection protection, image quality, value and performance.
1
Page 3
FEATURES
Camera:
Color camera with SONY 1/3” Super HAD II CCD sensor
Employs Digital Signal Processor (DSP) chip-set for high quality images
High Resolution over 600TVL
High sensitivity, low smear, high anti-blooming and high S/N ratio for high
performance video.
Built-in functions: Auto Electronic Shutter (AES), Auto Gain Control (AGC), Auto
Trace White Balance (ATW) Digital Wide Dynamic Range (DWDR), 2D Noise
Reduction (2DNR).
DC power cable and video cable and power pigtail provided
Built-in anti-aliasing function to improve perceived video image quality
PIR Motion Detector:
PIR motion sensor for intrusion protection with minimum false alarm ratio.
Adjustable sensitivity level
Adjustable relay time 2-40 sec.
Selectable 2 choices for pulse detection options
Built-in anti tamper switch
PACKAGE CONTENTS
PIR Detector with Hidden Camera Unit x 1
Mounting Bracket x 1
Operation Instructions (this document) x 1
Power adapter pigtail x 1
Screws x 2
2
Page 4
DIMENSIONS
3
Page 5
SPECIFICATIONS
Power Requirements (camera
(separate from
Model
Camera
ECMD200
Image Pick-up Device
Effective Picture Elements
Horizontal Resolution
Minimum Illumination
S/N Ratio
Auto Electronic Shutter
Gamma Characteristic
Lens Furnished
Gain Control Automatic
White Balance ATW (2,000°K~10,500°K)
Digital Wide Dynamic Range
2D Noise Reduction
Synchronous System
Video Output
Operating Temperature
Humidity
SONY 1/3’’ Super HAD II Color CCD
NTSC: 768*494
600 TV lines
0.05LUX @ F2.0
More than 52 dB
NTSC:1/60s~1/100,000s, PAL:1/50s~1/110,000s
0.45
Pinhole lens 3.7mm / F2.0
DWDR ON
2DNR ON
Internal
BNC-F; 1 V p-p Composite Video / 75 ohm
-10°C to 50°C (14°F to 122°F)
20%~ 80% non-condensing
only)
PIR Detection Angle Horizontal = 100° / Vertical = 45°
PIR Detection Range 10m
PIR N.C/N.O Relay Output 2A @ 24 AC/DC
PIR N.C/N.O Alarm Time Adjustable from 2 to 40 sec.
Case Open Tamper Switch
Power Supply
Camera)
Dimensions 4.72 x 2.76 x 1.89 inches
Weight 130 g / 0.29 lbs
12VDC regulated; 100mA
PIR Motion Detector
Built-in switch; trips alarm relay once if PIR case is opened.
Relay operation on switch activation is same as if a PIR
motion alarm is detected: single relay event as per VR2/J4
settings. This is NOT a separate ‘day zone’ or ’24 hour
zone’ type independent/continuous tamper output.
DC 12V; Standby current: 1mA; Working current: 25mA
Overall Mechanical
4
Page 6
INSTALLATION
Warning:
To prevent electrical shock, turn off the electrical power before making electrical connections.
1. Locate the desired mounting location; position housing with PIR detector and camera pointed
generally in the desired direction and mark location.
2. Select hole locations for direct installation or bracket mount installation. Drill pilot holes and
insert plastic anchors into holes after drilling. If wires will be hidden drill a minimum 5/8”
diameter hole for the power and video cables. Open the PIR detector casing by gently pulling
the front and back covers in opposite directions. Pass the motion detector power and contact
wires through the hole in the back of the case.
3. Connect the PIR detector power, N.O and N.C
wires. Also separately connect to the camera
coaxial power and BNC video connectors
(observe polarity for power – connecting
reverse polarity will damage the camera and
void the warranty).
5
Page 7
4. If not using the bracket provided (not recommended), attach the PIR detector back cover to
the mounting surface with the screws provided (Do not over tighten the screws). If corner
mounting the unit, drill a hole ~3/16” diameter in each edge, just below the motion detector
PCB. NOTE: If the bracket is NOT used, there is no way to change the camera
direction/aim the camera.
5. If you are using the mounting bracket (recommended), attach the bracket to the mounting
surface with the screws provided, then attach the PIR detector to the mounting bracket by
pressing the brackets plastic pins into the mounting holes in the back until they fit into place
6. Assemble the front cover to the back cover by pressing them together to lock them in place
6
Page 8
PIR DETECTOR CONFIGURATION
1. LED Selector:
J1
(3 PINS: Top, Center, Bottom)
2. Sensitivity Adjustment:
MAX
MIN
VR1
Detection range:
100。Wide angle/58 beams in 3
levels/Maximum coverage area:
35'x35'
3. Dwell Time Adjustment:
MIN MAX
A) Top+Center w/black jumper:- testing mode: Light
Blinking
B) Center+Low w/blackjumper: Normal detection mode: No
light blinking while detecting
1. To raise sensitivity turn clockwise
2. To lower sensitivity turn counter clockwise
Note: While adjusting you need to position LED selector as
indicated in (A)
To determine the time period of N.C/N.O relay to the alarm
panel/device
A) Max time: Turn counter clockwise
VR2
Adjustable from 2 to 40 sec
4. External Device Control:
(N.O or N.C)
J4
(3 PINS: Top, Center, Bottom)
B) Min time: Turn clockwise
Top + Center pins of "J4"must be selected to adjust the time
setting.
A) Top + Center w/black jumper: Operate with "VR2" to
adjust time. (Sets the relay output to the alarm system,
DVR or other accessory according to individual
preference or application.
B) Center + Bottom w/black jumper: Relay output set for a
Position 1: Set to "ONCE" for instant reaction when PIR
detects movement, the connected device/alarm
will be triggered immediately.
Position 2: Triggering will start after the PIR detects
movement twice within 15 seconds.
4 PINS 2 PAIRS w/Jumper connector
6. Terminals:
N.C N.O -- +
N.C: Normally closed
N.O: Normally open contacts
Input power (see below)
Relay output current: 2A 24VAC, 2A 24VDC
7. Power: 12V DC Standby current: 1mA
Working current: 25mA
8. Caution: Do not place in direct sunlight or reflected sunlight.
Jumpers and wiring terminals of PIR Detector:
OUTPUT TERMINALS
N.C N.O -- +
PULSE
COUNT
JP2
PULSE
1
2
J2
LIGHT CONTROL
RECORDING CONTROL
TIME
ADJUSTMENT
LED
SELECTOR
J1
VR2 J4 VR1
8
Page 10
EverFocus Electronics Corp.
Your EverFocus product is designed
Ihr EverFocus Produkt wurde entwickelt
EverFocus Taiwan:
12F, No.79, Sec. 1, Shin-Tai Wu Road,
Hsi-Chih, Taipei, Taiwan
TEL: +886 2 2698 2334
FAX: +886 2 2698 2380
www.everfocus.com.tw
marketing@everfocus.com.tw
EverFocus China - Beijing:
Room 609, Technology Trade Building,
Shangdi Information Industry Base,
Haidian District, Beijing 100085, China
TEL: +86 10 6297 3336~39
FAX: +86 10 6297 1423
www.everfocus.com.cn
marketing@everfocus.com.cn
EverFocus USA - California:
1801 Highland Avenue, Unit A, Duarte, CA 91010,
USA
TEL: +1 626 844 8888
FAX: +1 626 844 8838
www.everfocus.com
sales@everfocus.com
EverFocus Europe - Germany:
Albert-Einstein-Strasse 1, D-46446
Emmerich, Germany
TEL: +49 2822 93940
FAX: +49 2822 939495
www.everfocus.de
info@everfocus.de
EverFocus China - Shenzhen:
4F, No. 2, D4 Building, Wan Yelong
Industrial Park, Tangtou Road, Shiyan,
Baoan, Shenzhen, Guangdong 518101, China
TEL: +86 755 2765 1313
FAX: +86 755 2765 0337
www.everfocus.com.cn
marketing@everfocus.com.cn
EverFocus USA - New York:
415 Oser Avenue, Unit S, Hauppauge, NY 11788, USA
TEL: +1 631 436 5070
FAX: +1 631 436 5027
www.everfocus.com
sales@everfocus.com
EverFocus Japan:
5F, Kinshicho City Building, 2-13-4
Koto-Bashi,Sumida-Ku, Tokyo, 130-0022, Japan
TEL: +81 3 5625 8188
FAX: +81 3 5625 8189
www.everfocus.co.jp
info@everfocus.co.jp
EverFocus India:
Suite 803, Housefin Bhavan, C-21, Bandra Kurla
Complex, Bandra (East), Mumbai 400051, India
TEL: +91 22 6128 8700
FAX: +91 22 6128 8705
www.everfocus.in
sales@everfocus.in
and manufactured with high quality
materials and components which can
be recycled and reused.
This symbol means that electrical and
electronic equipment, at their
end-of-life, should be disposed of
separately from your household waste.
Please, dispose of this equipment at
your local community waste
collection/recycling centre.
In the European Union there are
separate collection systems for used
electrical and electronic product.
Please, help us to conserve the
environment we live in!
und hergestellt mit qualitativ
hochwertigen Materialien und
Komponenten, die recycelt und wieder
verwendet werden können.
Dieses Symbol bedeutet, dass
elektrische und elektronische Geräte am
Ende ihrer Nutzungsdauer vom
Hausmüll getrennt entsorgt werden
sollen.
Bitte entsorgen Sie dieses Gerät bei
Ihrer örtlichen kommunalen
Sammelstelle oder im Recycling Centre.
Helfen Sie uns bitte, die Umwelt zu
erhalten, in der wir leben
EverFocus Europe - UK:
Unit 12, Spitfire Business Park,
Hawker Road, Croydon Surrey, CR0 4WD, UK
TEL: +44 20 8649 9757 / +44 845 430 9999
FAX: +44 20 8649 9907
www.everfocusuk.co.uk
salesuk@everfocus.com
!
9
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.