Operating Manual alpha DO 1000
TABLE OF CONTENTS
1 INTRODUCTION ..................................................................................... 1
1.1 Description of Unit................................................................................................................1
1.2 Applications...........................................................................................................................1
2 ASSEMBLY AND INSTALLATION .........................................................2
2.1 Measurement and Control System .....................................................................................2
2.2 Unit Dimensions....................................................................................................................2
3 ELECTRICAL CONNECTION .................................................................3
3.1 Connection Diagram.............................................................................................................3
3.2 Back Panel.............................................................................................................................4
4 OVERVIEW.............................................................................................. 6
4.1 Keypad and Display..............................................................................................................6
4.1.1 Keypad......................................................................................................................6
4.1.2 Display......................................................................................................................6
4.2 Function Groups...................................................................................................................7
4.2.1 How to view operating parameters without access to change them: ......................7
4.3 Control Concept....................................................................................................................8
5 MEASUREMENT.....................................................................................9
5.1 Display in Measurement mode............................................................................................9
5.1.1 Check electrode performance...................................................................................9
5.1.2 Checking set points...................................................................................................9
5.2 Security Codes.....................................................................................................................10
5.2.1 How to enter and change parameters in Calibration mode ..................................10
5.2.2 Clearing the Calibration security code from the display.......................................10
5.2.3 How to enter and change parameters in Advanced Setup mode ...........................10
5.2.4 Clearing the Advanced Setup Security Code from the Display .............................11
6 CALIBRATION MODE .......................................................................... 12
6.1 Dissolved Oxygen Calibration...........................................................................................12
6.2 Dissolved Oxygen Calibration in % Saturation of Oxygen ...........................................13
7 ADVANCED SET-UP MODE................................................................. 15
7.1 Electrode Offest (OFS), Salinity and Pressure sub-function .........................................15
7.2 Setting the Salinity Value...................................................................................................16
7.3 Setting the Pressure Value (mmHg or Pascal) ................................................................16
7.4 Setting Temperature (Set °C) sub-function .....................................................................17
7.4.1 Selecting Automatic or Manual Temperature Compensation................................17
7.4.2 Temperature calibration (ATC mode only)............................................................17
7.4.3 Setting Manual Temperature Compensation .........................................................18
7.5 Control Relay A/Control Relay B (SP1/SP2) sub-function ............................................18
7.5.1 Entering the Set point 1 (or Set point 2) sub-function ...........................................19
7.5.2 Selecting the Set Point Values................................................................................19
7.5.3 Choosing High or Low Set-points..........................................................................19
7.5.4 Selecting a Hysteresis (Dead Band) Value............................................................20
7.5.5 Setting an On-Delay Time Lag...............................................................................20
7.5.6 Setting an Off-Delay Time Lag...............................................................................21
7.6 Controller (Cntr) Sub-Function........................................................................................22