Euchner CES-AR, CET-AR Data Sheet

Non-Contact Safety Switches CES-AR/CET-AR
Non-contact safety switches CES-AR-C01...
Read head with integrated evaluation
f
electronics
f
Up to 20 safety switches in series
f
Short circuit monitoring
f
2 safety outputs (semiconductor outputs)
f
Category 4 / PL e according to EN ISO 13849-1
Non-contact safety switches CES-AR-C01...
M12 plug, 8-pin
Dimension drawing
34
13
1...20
Cat. 4
PLe
40
For possible combinations see page 127
Approach direction
Can be adjusted in 90° steps
Short circuit monitoring
The switch generates its own clock signal on the output lines OA/OB. Pay attention to this aspect when connecting to control systems and relays.
Unicode evaluation
Each actuator is unique. The evaluation unit de­tects only the actuator that has been taught-in. Additional actuators can be taught-in. Only the last actuator taught-in is detected.
Multicode evaluation
Every actuator is detected by the evaluation unit.
Fixcode evaluation
An actuator is permanently allocated to the evalu­ation unit. The evaluation unit can be operated only with this actuator. The actuator is taught-in at EUCHNER prior to delivery. No additional actua­tors can be taught-in.
Category in accordance with EN ISO 13849-1
Due to two redundant design semiconductor outputs (safety outputs) with internal monitoring suitable for:
f
Category 4 / PL e in accordance EN ISO 13849-1
Important: To achieve the stated category in accordance with EN ISO 13849-1, both safety outputs (OA and OB) must be evaluated.
LED display STATE Status LED DIA Diagnostics LED
Additional connections OUT Monitoring output (semiconductor) RST Reset input
Ordering table
Series Category and PL according to EN ISO 13849-1 Order no.
CES-AR-C01-AH-SA
Unicode
CES-AR-C01-CH-SA
Multicode
Block diagram
For connection examples see page 150
Pin assignment
Pin Designation Description
1 IB Enable input for channel 2 white 2 UB Power supply, DC 24 V brown 3 OA Safety output, channel 1 green 4 OB Safety output, channel 2 yellow 5 OUT Monitoring output gray 6 IA Enable input for channel 1 pink 7 0V Ground, DC 0 V blue 8 RST Reset input red
5
6
7
View of connection side
of the safety switch
4 / PL e
4 / PL e
30
M12x1
IB1
CES-AR-C01-...
8
4
3
21
7
UB2
OA3
LED display
Ø5,5
47
IA6
OB4
OUT5
M12 plug-connector
(8-pin)
0V7
RST8
Wire color as per
098 941
CES-AR-C01-AH-SA
098 942
CES-AR-C01-CH-SA
DIN 47100
RST
UB
0V
IA
IB
OA
OB
OUT
For connection cable see page 144
8 2 7 6
1
3 4 5
128
Subject to technical modifications; no responsibility is accepted for the accuracy of this information.
Non-Contact Safety Switches CES-AR/CET-AR
Technical data non-contact safety switches CES-AR-C01...
Parameter
min. typ. max.
Value
Unit
Housing material PBT V0 GF30 Dimensions According to EN 60947-5-2 mm Weight 0.4 kg Ambient temperature at U Degree of protection IP67
= DC 24 V -20 - +55 °C
B
Safety class III Degree of contamination 3 Installation position Any Connection type M12 plug connector, 8-pin Operating voltage U
residual ripple < 5 %)
(reverse polarity protected, regulated,
B
24 ± 15% V DC
For the approval according to UL the following applies Operation with UL-class 2 power supply only, or equivalent measures Current consumption 80 mA
Switching load according to External fuse (operating voltage U Classification according to EN 60947-5-3 PDF-M
) 0.25 - 8 A
B
DC 24 V, Class 2
EMC protection requirements In acc. with EN 60947-5-3
Safety outputs
p-switching, short circuit-proof)
- Output voltage U(OA/U(OB) HIGH U(OA) UB - 1.5 - U HIGH U(OB) UB - 1.5 - U LOW U(OA)/U(OB) 0 - 1
(OA/OB, 2 semiconductor outputs,
1)
B
B
V DC
Switching current per safety output 1 - 400 mA Utilization category acc. to EN 60947-5-2 DC-13 24V 400mA
Off-state current I Rated insulation voltage U Rated impulse withstand voltage U Resilience to vibration According to EN 60947-5-2
r
i
imp
Caution: outputs must be protected with a free-wheeling diode in case of inductive
- - 300
loads
b 0,25 mA
2)
- - 1.5 kV
Switching frequency - - 1 Hz
Repeat accuracy R b 10 %
Monitoring output
(Semiconductor output, p-switching, short circuit-proof) Output voltage 0.8 x U Max. load - - 200 mA
(OUT)
B
-U
B
V DC
In combination with actuator CES-A-BBA/CES-A-BCA
Operating distance for center offset m = 0
- Switch-on distance - 18 -
- Assured switch-on distance s
- Switching hysteresis
- Assured switch-off distance s
In combination with actuator CES-A-BPA
Operating distance for center offset m = 0
- Switch-on distance - 22
- Assured switch-on distance s
- Switching hysteresis
- Assured switch-off distance s
In combination with actuator CES-A-BRN
Operating distance for center offset m = 0
- Switch-on distance - 27
- Assured switch-on distance s
- Switching hysteresis
- Assured switch-off distance s
Reliability values according to EN ISO 13849-1
2)
ao
2)
ar
ao
2)
ar
ao
4)
ar
15 - -
13 -
--45
3)
-
18 - -
12 -
--58
4)
-
20 - -
-3-
--75
Category 4 Performance Level (PL) e PFH
d
Mission time 20 years T
10d
1) Values at a switching current of 50 mA without taking into account the cable lengths.
2) Tested by BG up to 75 V.
3) Values apply for surface mounting of the actuator.
4) On surface mounting on aluminum, in a non-metallic environment the typical switching distance increases to 30 mm.
5) In case of surface mounting on steel.
6) Applying the limit value from EN ISO 13849-1:2008, section 4.5.2 (MTTF
= max. 100 years) BG certifies a PFHd BG certifies a 2.47 x 10-8.
d
2.1 x 10
20 years
-9
6)
/ h
V
mm
mm
mm
Subject to technical modifications; no responsibility is accepted for the accuracy of this information.
129
Loading...
+ 1 hidden pages