Non-Contact Safety System CES-AZ
17
5
32
19,
7
Read distance s
C
enter offse
t
m
connected
35
4
8
30
M 1
2x
1
M 8
x1
37
1)
1)
2
4
6
6
8
8
X
8
6
4
2
2
4
6
8
8
6
Y
Z
Read head CES-A-LMN-SC
Cylindrical design M12
plug connector (snap-
M8
action and screw terminals)
For possible combinations see
page 24
Warning:
The operating distance may vary depending on the background material
and installation situation.
Important:
Actuators must be ordered separately! See page 48.
Read head CES-A-LMN-SC
M8 plug, 3-pin
Dimension drawing
1) Clear zone (area of the active face without metal housing)
Typical operating distancePin assignment
Active face
For connection
cable see
page 65
1)
Ordering table
1) EX II 3G Ex nL IIC T70°C (zone 2 gases)
40
Screen
CES-AZ...
CES-A-LMN-SC
CES-A-LMN-SC-EX
Read head
A minimum distance of s = 1.2 mm must be maintained.
Series Connection type Type Order no. / item
SC
M8 plug connector
SC
M8 plug connector
Subject to technical modifications; no responsibility is accepted for the accuracy of this information.
Housing M12
1)
ATEX
077 790
CES-A-LMN-SC
1)
098 157
CES-A-LMN-SC-EX

Non-Contact Safety System CES-AZ
Technical data read head CES-A-LMN-SC
Parameter Value Unit
min. typ. max.
Housing material Nickel-plated CuZn housing sleeve
Dimensions M12 x 1, length 38 mm
Weight 0.2 kg
Ambient temperature
- CES-A-LMN-SC-EX -20 - +60
Ambient pressure
(only of active face in installed condition)
Degree of protection IP67
Installation position Any
Method of operation Inductive
Power supply Via evaluation unit
In combination with actuator CES-A-BMB
Operating distance for center offset m = 0
- Assured switch-off distance S
Cable length l = 0 to 15 m
- Switch-on distance - 5 -
- Assured switch-on distance S
- Switching hysteresis 0.1 0.3 -
Connection M8 plug connector (snap-action and screw terminals), 3-pin
Cable length - - 15 m
1) These values apply for surface installation of the read head in steel.
ar
ao
1)
- - 10 bar
- - 10
3.5 - -
Plastic PBT GF20 cap
°C- CES-A-LMN-SC -20 - +70
mm
Subject to technical modifications; no responsibility is accepted for the accuracy of this information.
41