AS-i 3.0 PROFIBUS DP Gateway Double Master with integrated Safety Monitor for 2 AS-i networks
Commissioning / Inbetriebnahme
classic mode / klassischer Modus
1.12A
underlined data can be selected
unterstrichene Werte sind anwählbar
AS-I SAFETY
TEACH SAFETY
SAFE OUTPUT CH
SAFE COUPLING
START/ST O P
CLEAR SAFE CFG
PIN
SAFE CHIPCARD
PROTECT
SAFE SUBST VAL
advanced display mode / erweiterter Display-Modus
TEACH CODES
COMPLETE
SINGLE SLAVE
COUPLING SLAVE
SNGL SLAVE CODE
SAFE OUTPUT
CHANNELS
CH 1: ON
CH 2: OFF
...
CH 16: OFF
SAFE COUPLING
ON CHANNEL 2
ADR <XY>
<DISABLE>
START/STOP
ENTER PIN
0000
OK
CLEAR SAFE CFG
ENTER PIN
0000
OK
CHANGE PIN
ENTER PIN
0000
OK
SAFE CHIPCARD
ACTIVE: BANK B
VIEW
CARD -> MONITOR
MONITOR -> CARD
CLEAR CODES
CLEAR SAFE CARD
PROTECT
ENTER PIN
0000
OK
AS-I CIRCUIT 1
AS-I CIRCUIT 2
PROFIBUS
QUICK SETUP
AS-I SAFETY
DIAGNOSIS
SLAVE ADR TOOL
TEST
SETUP
DISPLAY CONTRAST
TEACH CODES
ENTER PIN
0000
OK
TEACH CODES
ENTER PIN
0000
OK
AS-I CIRCUIT 1
AS-I CIRCUIT 2
START/STOP
STOP
CHANGE
CLEAR SAFE CFG
CLEAR
CHANGE PIN
ENTER NEW PIN
0000
0000
OK
SELECT BANK
A
OK
ENTER PIN
0000
OK
ENTER PIN
0000
OK
ENTER PIN
0000
OK
ENTER PIN
0000
OK
DOWNLOAD
NOT ALLOWED
CHANGE
SAFE SUBST VAL
SUBSTITUTE
CHANGE
items in italic are not always available
kursive Einträge sind nicht immer vorhanden
TEACHING CODES
SLAVE ADDR. 2(1)
OK
ESC OK
COUPLING SLAVE
SLAVE ADDR 2(1)
ESC OK
SLAVE ADDR 2
ENTER CODE (1)
00000000
ESC OK
BANK A CONFIG
COMPLETE
CONFIGURATION:
RELAIS IMMER AN
MON. VER.: 3.0
RELEASED:
BY ROLF BECKER
ON 2008/01/21
AT 13:52
RELEASE CODE:
B1D2
SELECT BANK
A
OK
SELECT BANK
A
CLEAR
TEACHING CODES
CLOSE CONTACTS
AS-I 1:
| 1-OK
2-RX | 3-RR
.... |
30-DC | 31-DC
AS-I 2:
| 1-OK
2-RX | 3-RR
.... |
30-DC | 31-DC
....
HELP
NO SAFETY SL
MS MISSING SLAVE
X CH OK
R CH RELEASED
OK CODE LEARNED
DC DUPL.CODE
ER CODE ERROR
START MONITOR
OK
COPY BANK A TO
MONITOR
CONFIGURATION:
RELAIS IMMER AN
MON. VER.: 3.0
RELEASED:
BY ROLF BECKER
ON 2008/01/21
AT 13:52
RELEASE CODE:
B1D2
-----------------------------RELEASE CODE
1BDF OK
STOP MONITOR?
OK
Basic Operation
The device starts in the traditional mode. You can switch between the two modes with ESC or OK. In the advanced mode the
cursor is moved by the arrow buttons. Pushing OK puts you to the superior menu (in the drawing one step to the right side).
ESC puts you back to the previous menu. To edit data move with arrow buttons the marking to desired line first and then select
the item with OK, change the data by using the arrow buttons and finally press OK button to accept the input. Pushing ESC
cancels the editing.
Grundlegende Bedienungshinweise
Das Gerät startet im klassischen Modus. Mit ESC oder OK kann zwischen dem klassischen und dem erweiterten Modus
gewechselt werden. Im erweiterten Modus wird der Cursor mit den Pfeil-T asten bewegt. OK wechselt ins nächsthöhere Menü.
ESC wechselt zurück ins vorherige Menü. Die zu editierenden Werte zunächst mit dem Cursor markieren, dann mit
Technische Änderungen vorbehalten, alle Angaben ohne Gewähr Id.-No.: 104137 Issue date - 9.6.08 EUCHNER GmbH + Co. KG
Seite 1 Kohlhammerstraße 16 D-70771 Leinfelden-Echterdingen Tel. +49/711/75 97-0 Fax. +49/711/753316

AS-i 3.0 PROFIBUS DP Gateway Double Master with integrated Safety Monitor for 2 AS-i networks
Commissioning / Inbetriebnahme
underlined data can be selected
unterstrichene Werte sind anwählbar
DIAGNOSIS
LCS LIST OF
CORRUPTED SLAVES
RESET
| 1A-X
2A- | 3A4A-X | 5A-X
....
30A-X | 31A | 1B-X
2B-X | 3B-X
4B-X | 5B-X
....
30B-X | 31B-X
LPF LIST OF
PERIPH. FAULTS
| 1A-X
2A- | 3A4A-X | 5A-X
....
30A-X | 31A | 1B-X
FLAGS: 0131 05
0000 0001
0011 0001
0000 0101
0000 0101
1 PERIPHERY_OK
0 OFFLINE_READY
0 AS-I_PWR_FAIL
1 NORMAL_OP.
1 CONFIG_ACTIVE
0 AUTO_ADDR_AVL
0 AUTO_ADDR_ASN
0 LDS.0
0 CONFIG_OK
1 AUTO_ADDR_ENA
0 OFFLINE
1 DATA_EXCH_ACT
ACTUAL CONFIG
0A | 1A-C
....
30A-X | 31A-D
| 1B-X
....
30A | 31B-F
HELP:
X O.K.
D DETECTED ONLY
UNKNOWN SLAVE
P PROJ. ONLY
MISSING SLAVE
C TYPE CONFLICT
F PERIPH. FAULT
A DUPLICATE ADR
AS-I CIRCUIT 1
SWID:
31256
FEATURE STRING: 2
.B..DC2
DOA.AUT
SAFE CPU A:
31166
SAFE CPU B:
31158
UART 1:
29642
UART 2:
29642
SAFETY SLAVES
INT MONITOR
EXT MONITOR
FAULT DETECTOR
DELTA LIST
LCS
ERROR COUNTERS
LPF
FLAGS
ACTUAL CONFIG
AS-I CIRCUIT 2
AS-I MASTER
classic mode / klassischer Modus
.12A
advanced display mode / erweiterter Display-Modus
AS-I CIRCUIT 1
AS-I CIRCUIT 2
AS-I CIRCUIT 1
AS-I CIRCUIT 2
PROFIBUS
QUICK SETUP
AS-I SAFETY
DIAGNOSIS
SLAVE ADR TOOL
TEST
SETUP
DISPLAY CONTRAST
SAFETY ORIENTED
SLAVES
| 1-XX
2-RX | 3-RR
4- | 5...
HELP:
X CHANNEL OK
R CH. RELEASED
ON OUTPUT ON
OFF OUTPUT OFF
? OUTPUT STATE
UNKNOWN
INT SAFETY MON
DIAGNOSIS
LAST DIAGNOSIS
VIEW CONFIG
EXT SAFETY MON
ADDRESS 10
MODE: SORTED/V1
OK
FAULT DETECTOR
RESET
HISTORIC:
EFLT OVRV NOIS
ACTUAL:
EFLT OVRV NOIS
DUP ASI ADR:
0 |31B
HELP:
EFLT EAR T H FAULT
OVRV OVERVOLTAGE
NOIS NOISE
DUP ASI ADR
DUPLICATE ASI
SLAVE ADDRESS
DELTA LIST
0- | 1A-X
2A-X | 3A-X
4A-X | 5A-X
....
30A-X | 31A | 1B
2B- | 3B
....
30B | 31B
ERROR COUNTERS
FOR SLV. DETAILS
PRESS OK ON ADDR
RESET
1A- 0
...
31A- 65535
1B- 34
...
30B- 0
INT SAFETY MON
COMPLETE
DIAG INDEX
DIAGNOSIS
CH 1
OK
Safety Monitor Generation II
EXT SAFETY MON
DIAGNOSIS
LAST DIAGNOSIS
VIEW CONFIG
SLAVE ADDR. 4A
NO SLV.:
5
NO SLV. TEL.:
31
SLV. TEL. ERR.:
1
PERIPH. FAULTS:
2
PROTOCOL FAULT:
1
Safety Monitor Generation I
INT SAFETY MON
DIAGNOSIS
STATUS: CFG
...
ASI 1
SLAVES
| 1-XX
2-RX | 3-RR
....
AS-I 2
....
A COLOR
HELP:
X CHANNEL OK
R CH. RELEASED
ON OUTPUT ON
OFF OUTPUT OFF
? OUTPUT STATE
UNKNOWN
A DEVICE ADDRES
LAST DIAGNOSIS
CH1 COMPLETE
DIAG INDEX
MONITOR CONFIG
COMPLETE
CONFIGURATION
FGDG
MON.VER.: 3.0
RELEASED
BY SA
ON 2007/11/15
AT: 14:30
RELEASED CODE:
81FE
MONITOR CONFIG
COMLETE
CONFIGURATION
FGDG
MON. VER.: 3.0
RELEASED
by SA
ON
2007/14/15
AT 14:43
RELEASE CODE:
81FE
INT SAFETY MON
LAST DIAG CH1
STATUS: CONFIG
CH1.: OFF
A COLOR
32 RED
33 GREY
34 YEL FL
....
HELP:
A DEVICE ADDRES
+ CHANGED
EXT SAFETY MON
DIAGNOSIS
MODE: UNSORTED
CH1.: ON
...
ASI 1
SLAVES
| 1-XX
2-RX | 3-RR
4- | 5...
A COLOR
32 RED
HELP:
X CODE OK
R RELEASED
A DEVICE ADDRES
EXT SAFETY MON
COMPLETE
DIAG INDEX
DIAGNOSIS
CH 1
OK
LAST DIAGNOSIS
CH1 COMPLETE
DIAG INDEX
EXT SAFETY MON
LAST DIAG CH1
CH1.: OFF
A COLOR
32 RED
33 GREY
34 YEL FL
....
HELP:
A DEVICE ADDRES
+ CHANGED