ETS-Lindgren 8100-041, 8100-040 User Manual

Model 8100-041
RF Power Amplifier
User Manual
www.ets-lindgren.com
ETS-Lindgren Inc. reserves the right to make changes to any products herein to improve functioning or design. Although the information in this document has been carefully reviewed and is believed to be reliable, ETS-Lindgren does not assume any liability arising out of the application or use of any product or circuit described herein; nor does it convey any license under its patent rights nor the rights of others. All trademarks are the property of their respective owners.
© Copyright 2015 by ETS-Lindgren Inc. All Rights Reserved. No part of this document may be copied by any means without written permission from ETS-Lindgren Inc.
Trademarks used in this document: The ETS-Lindgren logo is a registered trademark and Calibration Services Plus! is a trademark of ETS-Lindgren Inc.
Revision Record
MANUAL,8100-041 | Part #399646 Rev. B
Revision
Description
Date
A
Initial Release
September, 2015
B
Updated fuse type
October, 2015
www.ets-lindgren.com
iii
Table of Contents
Notes, Cautions, and Warnings ........................................................................ vi
Safety Information ............................................................................................. vi
1.0 Introduction ................................................................................................... 7
Standard Configuration ....................................................................................................... 8
Optional Items ..................................................................................................................... 8
Rack Mount Brackets .................................................................................................... 8
2.0 Maintenance ................................................................................................ .. 9
Maintenance Recommendations ...................................................................................... 10
Troubleshooting ................................................................................................................ 10
Replacement and Optional Parts...................................................................................... 11
Service Procedures .......................................................................................................... 11
Contacting ETS-Lindgren ............................................................................................ 11
Sending a Component for Service .............................................................................. 11
Calibration Services .................................................................................................... 11
3.0 Specifications .............................................................................................. 13
Electrical Specifications .................................................................................................... 13
Physical Specifications ..................................................................................................... 13
4.0 Before You Begin ........................................................................................ 15
Setting up the Amplifier .................................................................................................... 15
Rack Mounting .................................................................................................................. 15
5.0 Pre-Installation Tasks ................................................................................. 17
Mains Connection ............................................................................................................. 17
RF Connectors .................................................................................................................. 17
Interlock Safety Loop ........................................................................................................ 17
6.0 Operation ..................................................................................................... 19
Front Panel View .............................................................................................................. 19
Rear Panel View ............................................................................................................... 20
Manual Operation ............................................................................................................. 21
Remote Control via the IEC/IEEE-488.2 GPIB Interface.................................................. 25
Setting the GPIB Instrument Address ......................................................................... 26
Interface Messages ..................................................................................................... 26
Device Messages ........................................................................................................ 27
Remote Control via the Ethernet Interface ....................................................................... 30
Administration by LAN ................................................................................................. 31
Ethernet Control Commands ...................................................................................... 35
Status Messages of the Amplifier in Ethernet Remote Control Mode ........................ 36
iv
www.ets-lindgren.com
Remote Control and Interlock Interface ............................................................................ 37
Appendix A: Warranty ...................................................................................... 39
Scope and Duration of Warranties ................................................................................... 39
Warranty Exclusions ......................................................................................................... 40
Buyer’s Remedies............................................................................................................. 40
Appendix B: EC Declaration of Conformity ................................ .................... 43
www.ets-lindgren.com
v
List of Figures
Figure 1: Amplifier block diagram ................................................................................................. 8
Figure 2: Pin assignment of remote control and interlock connector ......................................... 17
Figure 3: Example of interlock safety loops ............................................................................... 18
Figure 4: Front panel view .......................................................................................................... 19
Figure 5: Rear panel view .......................................................................................................... 20
Figure 6: User Menu ................................................................................................................... 23
Figure 7: Pin assignment of IEEE connector ............................................................................. 25
Figure 8: IEEE universal commands .......................................................................................... 26
Figure 9: IEEE addressed commands ....................................................................................... 26
Figure 10: ASCII/ISO and IEC character set ............................................................................. 27
Figure 11: IEEE interface commands ........................................................................................ 28
Figure 12: IEEE interface status messages ............................................................................... 29
Figure 13: Pin configuration of the Ethernet interface................................................................ 30
Figure 14: Ethernet interface commands ................................................................................... 35
Figure 15: Ethernet interface status messages ......................................................................... 36
Figure 16: Signals at the remote control and interlock connector .............................................. 37
vi
www.ets-lindgren.com
Notes, Cautions, and Warnings
Note: Denotes helpful information intended to provide tips for better use of the
product.
CAUTION: Denotes a hazard. Failure to follow instructions could result in minor personal injury and/or property damage. Included text gives proper procedures.
WARNING: Denotes a hazard. Failure to follow instructions could result in SEVERE personal injury and/or property damage. Included text gives proper procedures.
Safety Information
Refer to Manual: When product is marked with this symbol, see the instruction manual for additional information. If the instruction manual has been misplaced, download it from www.ets-lindgren.com, or contact ETS-Lindgren Customer Service.
High Voltage: Indicates presence of hazardous voltage. Unsafe practice could result in severe personal injury or death.
Protective Earth Ground (Safety Ground): Indicates protective earth terminal. You should provide uninterruptible safety earth ground from the main power source to the product input wiring terminals, power cord, or supplied power cord set.
Waste Electrical and Electronic Equipment (WEEE) Directive: (European Union) At end of useful life, this product should be deposited at an appropriate waste disposal facility for recycling and disposal. Do not dispose of with household waste.
www.ets-lindgren.com
Introduction
7
1.0 Introduction
The ETS-Lindgren Model 8100-041 RF Power Amplifier can deliver an output power of 25 W over the frequency range of 700 to 6000 MHz.
The five-stage solid-state amplifier is of modular design and integrated into one RF module featuring a high linearity and a flat frequency response.
In order to achieve a stable output power, the bias of the amplifier stages is controlled by low-drift voltage regulators.
The maximum input power for achieving the nominal output power is 0 dBm corresponding to 1 mW or 0.224 V into 50 . Due to its gain reserve, the amplifier usually achieves full output power with an input power of -5 dBm.
The final stage is separately protected against overload by current limitation. The amplifier is protected against open circuit and short circuit at the output. By using suitable transistors and a special circuit design in the final stage, even a total mismatch at the output will not cause any damage. For a VSWR 2:1 the maximum power can be obtained, all specifications being met.
The amplifier housing is designed to ensure minimum RF leakage and high RF immunity. The module is supplied with DC voltage via RF feed through filters.
In order to protect the amplifier against thermal overload in case the blower fails or the ambient temperature is too high, a temperature sensor is mounted on the heat sink in the vicinity of the final stage.
8
Introduction
www.ets-lindgren.com
Standard Configuration
Figure 1: Amplifier block diagram
Optional Items
RACK MOUNT BRACKETS
Set of two brackets for fixing the amplifier in standard 19” racks.
Remote Control and Interlock Connector
IEEE Connector
(Option A)
Directional Coupler
Temperature Sense
RF Input
Mains
Control Unit
Power Supply
+28V
RF Output
Keyboard Card
Ethernet Connector
+12V
Final stage Module
www.ets-lindgren.com
Maintenance
9
2.0 Maintenance
CAUTION: Before performing any maintenance, follow the information provided in Safety Information on page vi.
WARNING: Maintenance of this power amplifier is limited to external components such as cables or connectors. If you have any questions concerning maintenance, contact ETS-Lindgren Customer Service.
Clean the exterior of the cabinet using a damp cloth and mild cleaner. Always unplug the unit before cleaning.
To prevent electrical shock, do not remove cover.
Warranty may be void if the housing is opened.
If you have any questions concerning maintenance, contact ETS-Lindgren Customer Service.
WARRANTY
10
Maintenance
www.ets-lindgren.com
Maintenance Recommendations
In general, the amplifier does not require any maintenance due to its solid-state amplifier design and overrating of all components under thermal stress.
The fans have a lifetime 40,000 h; this results in a lifetime of 5 years even with permanent operation.
Cleaning and care of the RF connectors are to be performed according to the regulations valid for N-series connectors. All mechanical and electrical specifications are guaranteed for at least 500 plug-in cycles.
Troubleshooting
If the green control light inside the mains switch does not light after turning mains on, please check the following.
No response after switching Check the fuses at the line input at the rear the mains switch on: panel of the amplifier. Check the mains voltage at the mains connector.
If a fault message will be displayed, the following should be checked:
Display: Interlock External Check the connection to the external
interlockswitch or jumper in the interlock connector (see Figure 2 on page 17 and Figure 3 on page 18).
Display: Temperature X Check whether the airflow is obstructed. Check if the internal blower works. Check if the ambient temperature is more than +45 °C. Allow the instrument to cool down and try to start again. Check if the Fault message persists.
Display: PowerSupply X Fault of one or more output voltages of the indicated power supply X. Switch off the amplifier and try to start again. Check if the Fault message persists.
Display: TTL or GPIB or LAN Press the Control key until the display indicates LOCAL. The amplifier can now be activated locally.
If a non-permanent error message is being displayed it has to be confirmed by pushing the Standby/Operate key at the front panel before the fault status will be unlatched.
www.ets-lindgren.com
Maintenance
11
Replacement and Optional Parts
Note: ETS-Lindgren may substitute a similar part or new part number with the
same functionality for another part/part number. Contact ETS-Lindgren for questions about part numbers and ordering parts.
Service Procedures
CONTACTING ETS-LINDGREN
Note: Please see www.ets-lindgren.com for a list of ETS-Lindgren offices,
including phone and email contact information.
SENDING A COMPONENT FOR SERVICE
1. Contact ETS-Lindgren Customer Service to obtain a Service Request Order (SRO).
2. Briefly describe the problem in writing. Give details regarding the observed
symptom(s) or error codes, and whether the problem is constant or intermittent in nature. Please include the date(s), the service representative you spoke with, and the nature of the conversation. Include the serial number of the item being returned.
3. Package the system or component carefully. If possible, use the original packing materials or carrying case to return a system or system component to ETS-Lindgren.
CALIBRATION SERVICES
Annual CalibrationFor reliable and repeatable long-term performance, annual
recalibration of your measuring device by an ETS-Lindgren experienced technician is recommended. The ETS-Lindgren calibration team will calibrate most any type or brand of measuring device. Additional information is available at
www.ets-lindgren.com/calibration.
Calibration Services Plus!™—Calibration Services Plus! is a customized, optional
program to help you expertly maintain your test and measurement assets. It is designed to address the challenges of managing the calibration and repair of test and measurement components, including scheduling and planning to ensure peak performance. Additional information is available at
www.ets-lindgren.com/maintenance.
12
Maintenance
www.ets-lindgren.com
This page intentionally left blank.
www.ets-lindgren.com
Specifications
13
3.0 Specifications
Electrical Specifications
Frequency range
0.7 to 6 GHz
Output power
25 W cw min.
Gain
44 dB min.
Input power
0 dBm max. to get nominal output power +10 dBm max. for no damage
Harmonics
-15 dBc min. (2nd), -20 dBc min. (3rd)
Spurious
-50 dBc min.
AC supply
100 VAC to 240 VAC, ±10% 47 Hz to 63 Hz
Line power
500 VA
RF connectors (input/output)
N-f, on rear panel
Impedance (input/output)
50 Ohms
VSWR (input/output)
2:1 typ.
Load VSWR
Infinite for no damage
Remote control interfaces
GPIB, LAN, TTL
Physical Specifications
Dimensions (WxHxD)
430 mm x 89 mm (2 HU) x 430 mm
16.9 in x 3.5 in x 16.9 in
Weight
12 kg (26 lb)
Ambient temperature
0°C to +45°C (+32°F to +113°F)
Storage temperature
-20°C to +85°C (-4°F to +185°F)
Humidity
95% max. (non condensing)
Vibration and shock
Acc. MIL-STD 810F
Altitude
7000 ft above sea level
14