ETC ETS-SBB, ETS-RM Data Sheet

Page 1
®
EchoTouch ControllerETC
PoE 802.3af
24VDC
Control Series
GENERAL INFORMATION
EchoTouch offers compact, stylish, and intuitive touchscreen control of lighting in architectural and small entertainment spaces. Combining three powerful capabilities into one elegant device, EchoTouch provides standalone or integrated Unison Echo® control. The 7” touchscreen interfaces provides status and control of all connected Echo products, as well as direct control for DMX/RDM, sACN and ArtNet devices. EchoTouch shines in all environments, whether in a commercial building with users who need to choose between preset looks, or in an event space to create and recall looks.
FEATURES
• Supports 40 control zones
• Support for playback of 64 presets and 4 sequences
• Support for DMX, RDM, sACN, ArtNet and EchoConnect protocols
• User customized interface
• Multilevel security access
• PoE or 24V powered
• Mounts to a standard 3-gang back box
• EchoConnect: two-wire topology-free system gives you the freedom to easily place stations wherever they are needed
ORDERING INFORMATION
Product
MODEL DESCRIPTION
ETS-_ EchoTouch Controller
Enter station color code in __ space provided: 1 = Cream (RAL 9001)
3 = Gray (RAL 7001)
4 = Black (RAL 9004)
5 = Signal White (RAL 9003)
Accessories:
MODEL DESCRIPTION
ETS-SBB EchoTouch Surface-Mount Back Box
ETS-RM EchoTouch Rack-Mount Kit
APPLICATIONS
• Small entertainment spaces
• Hospitality
• Healthcare facilities
• Conference and meeting rooms
• Lobby spaces
• Retail
• Houses of worship
ECHO INFORMATION
Echo Power Requirements
EchoConnect: One unit of output power
Auxiliary Power: 400mA
1) Auxiliary power is not required when using PoE
2) An EchoConnect power supply is required when connecting to an Echo Control System
Echo Presets
Supports 64 Echo Presets
1 of 7
Page 2
EchoTouch ControllerETC
SPECIFICATIONS
FUNCTIONAL
• Supports 40 control zones
- The first 16 can be used to control EchoConnect devices
• Supports playback of 64 Presets and 4 internal Sequences with one active at any time
• User customized touchscreen interface with support for layout and naming of:
- Seven User pages
- Zone faders (up to 11 per page)
- Preset, Sequence and Off buttons (up to 30 per page)
- Six user definable utility buttons
• Color and White Pickers with programmable color chips
• Innovative touch-based parameter controls
• On-board help system
• Extensive, searchable fixture library with support for RDM fixture discovery
• Two configurable security levels for user access and setup
• Adjustable time out options including: dim, off, or user selectable inactivity image
PROTOCOLS
• Support for DMX (ANSI E1.11), RDM (ANSI E1.20), sACN (ANSI E1.31), ArtNet, and EchoConnect protocols
• Support for up to 512 simultaneous addresses using any combination of output protocols
• EchoConnect output of up to 16 zones
• Connects to EchoConnect station bus for use with all Echo control and output products
MECHANICAL
• 7” color multi-touch touchscreen with adjustable backlight
• 800 x 480 screen resolution
• Cast zinc bexel finished in fine textured powder coat paint available in four standard colors:
- Cream (RAL 9001), Gray (RAL 7001), Black (RAL 9004), and White (RAL 9003)
• No visible means of attachment
• Flush-mount to industry standard 3-gang back box (RACO 697 or equivalent)
• Back box for surface mount applications available from ETC
ELECTRICAL
• RJ45 connector compliant with IEEE 802.3i for 10BASE-T, and 802.3u for 100BASE-TX
• Powered using 802.3af for Power over Ethernet
- Optional 24VDC power input for use with non-PoE systems
• Pluggable rising clamp screw terminal connector for Auxiliary Power and EchoConnect wiring
• Pluggable rising clamp screw terminal or IDC connector for DMX wiring
• USB port for firmware maintenance, file transfer, and show file storage
ECHOCONNECT
• Connects via two-wire EchoConnect control network using low-voltage Class 2 wiring
- Topology-free wiring over Belden 8471 or equivalent and one #14 ESD drain wire
• Supports use of Belden 1583A or equivalent Ethernet control wire when used with IDC termination kit
• Wiring may be bus, loop, homerun, or any combination of these
• Supports up to 500 meters (1,640 feet) of control wiring
- Up to 1,000 feet using Cat5
DMX
• Connector designed for use with Belden 9729 (or equivalent)
• Optional header included for use with Belden 1583A (or equivalent)
• Fully optically isolated from controller electronics
• Withstands fault voltages up to 250VAC
REGULATORY AND COMPLIANCE
• UL and cUL Listed
• CE Marked
• RoHS compliance
• WEEE
THERMAL
• Ambient temperature: 0-40°C / 32-104°F
• Ambient humidity: 5-95% non-condensing
Control Series
2 of 7
Page 3
ECHO FAMILY OF PRODUCTS
EchoTouch ControllerETC
Control Series
EchoConnect Power Supplies
MODEL DESCRIPTION
E-SPS 6U Room Station Power Supply, Knockout Mount
E-SPS-DIN 16U DIN rail Station Power Supply with 24V Aux
E-SPM 16U DRd Station Power Module
E-SPM-A 16U DRd Station Power Module with 24V Aux
E-SPM-RM 16U Rack-Mount Station Power Module Aux
E-SPM-RM-A 16U Rack-Mount Station Power Module 24V Aux
E-SPM-WM 16U Wall-Mount Station Power Module
E-SPM-WM-A 16U Wall-Mount Station Power Module 24V Aux
E-APS 24V Aux Power Supply, Knockout Mount
EchoTouch
MODEL DESCRIPTION
ETS EchoTouch Controller
Echo Stations
MODEL DESCRIPTION
E1001 Inspire One Button Station
E1002 Inspire Two Button Station
E1004 Inspire Four Button Station
E1006 Inspire Six Button Station
E1008 Inspire Eight Button Station
E1104 Inspire Four Button with Fader Station
EPS05 Echo Preset Station - 5 Button
EPS10 Echo Preset Station - 10 Button
EPSLO Echo Lockout Station
E-ATC Echo TimeClock
Echo Interfaces
MODEL DESCRIPTION
EACC EchoAccess Interface
EEB Echo Expansion Bridge
EDMXC Echo DMX Scene Controller
EEI Echo-Echofl ex Interface
ECII Echo Contact Input Interface
ECOI Echo Contact Output Interface
EDRI Echo Demand Response Interface
EBI Echo BACnet Interface
Zone Controllers
MODEL DESCRIPTION
ERC-G2 One Zone Relay Controller
EDRC-G2 Two Zone Relay Controller
ELD-G2 One Zone 0-10V Controller
EDLD-G2 Two Zone 0-10V Controller
ESSC-G2 One Zone SmartSpace Controller
EDSSC-G2 Two Zone SmartSpace Controller
ELVD-G2 600-Watt Phase Adaptive Dimmer
ELVD-277-G2 600-Watt Phase Adaptive Dimmer- 277V
Room Controllers
MODEL DESCRIPTION
ERMC4-G2 Four Zone Room Controller
ERMCT4-G2 Four Zone Room Controller with TimeClock
ERMC8-G2 Eight Zone Room Controller
ERMCT8-G2 Eight Zone Room Controller with TimeClock
Echo Responsive Controls
MODEL DESCRIPTION
ELS Light Sensor
EOCC Ceiling-Mount PIR Occupancy Sensor
EVAC Ceiling-Mount PIR Vacancy Sensor
E-DOC-C Ceiling-Mount Dual Tech Occupancy Sensor
E-DVAC-C Ceiling-Mount Dual Tech Vacancy Sensor
E-DOC-W Wall-Mount Dual Tech Occupancy Sensor
E-DVAC-W Wall-Mount Dual Tech Vacancy Sensor
E-DOC-SM1 Switch-Mount Dual Tech Sensor - One Button
E-DOC-SM2 Switch-Mount Dual Tech Sensor - Two Button
Panel Products
MODEL DESCRIPTION
ERP Echo Relay Panel Mains Feed
ERP-FT Echo Relay Panel Feed Through
SensorIQ Sensor IQ Intelligent Breaker System
SR3 Sensor3 Power Control System
DRd Unison DRd with Echo Control
3 of 7
Page 4
EchoTouch ControllerETC
1Ø, 2 WIRE + GND
120V / 60 Hz.
20A MAX.
(BY OTHERS)
PS435 24V DIN-RAIL MOUNT
POWER SUPPLY
DMX OUT PLUG-IN STATION
ECPB-DMX OUT
DMX 2 OUTPUT
DMX CABLE
COLORSOURCE PAR
LED INDOOR FIXTURE
DMX CABLE
COLORSOURCE PAR
LED INDOOR FIXTURE
ECHOTOUCH
CONTROLLER - ETS
NET3 ONE-PORT
OUTPUT GATEWAY
ARCSYSTEM PRO
FOUR-CELL ROUND LUMINAIRE
ECHOTOUCH
CONTROLLER - ETS
NET3 ONE-PORT
OUTPUT GATEWAY
ARCSYSTEM PRO
FOUR-CELL ROUND LUMINAIRE
ARCSYSTEM PRO
FOUR-CELL ROUND LUMINAIRE
ARCSYSTEM PRO
FOUR-CELL ROUND LUMINAIRE
~
TO ADDITIONAL
FIXTURES
~
TO ADDITIONAL
FIXTURES
24VDC DMX
NETWORK
NETWORK
NETWORK
DMX
DMX DMX
DMX DMX
DMX
SINGLE PHASE, 2 WIRE + GND
120V / 60Hz.
20A MAX.
(BY OTHERS)
8-PORT SIMPLE
NETWORK BOX
ECHOTOUCH
CONTROLLER - ETS
ECHO EDMXC (DIN)
1Ø, 2 WIRE + GND
120V / 60 Hz.
20A MAX.
(BY OTHERS)
ECHO E-SPS-DIN
DMX PLUG-IN STATION
ECPB-DMX
DMX 1 INPUT
DMX OUT PLUG-IN STATION
ECPB-DMX OUT
DMX 2 OUTPUT
DMX CABLE
COLORSOURCE PAR
LED INDOOR FIXTURE
DMX CABLE
COLORSOURCE PAR
LED INDOOR FIXTURE
DMX CABLE
ECHOTOUCH
CONTROLLER - ETS
1Ø, 2 WIRE + GND
120V / 60 Hz.
20A MAX.
(BY OTHERS)
ECHO E-SPS-DIN
NET3 ONE-PORT
OUTPUT GATEWAY
ARCSYSTEM PRO
FOUR-CELL ROUND LUMINAIRE
~
TO ADDITIONAL FIXTURES
DMX OUT PLUG-IN STATION
ECPB-DMX OUT
DMX 2 OUTPUT
DMX CABLE
COLORSOURCE PAR
LED INDOOR FIXTURE
DMX CABLE
COLORSOURCE PAR
LED INDOOR FIXTURE
ECHO INSPIRE-E1008
CONTROL STATION
Preset3Preset
4
Preset5Preset
6
Preset1Preset
2
Preset7Preset
8
ECHO INSPIRE-E1008
CONTROL STATION
Preset3Preset
4
Preset5Preset
6
Preset1Preset
2
Preset7Preset
8
DMXDMX
EchoConnect
24VDC
EchoConnect
24VDC
EchoConnect
24VDC
EchoConnect EchoConnect
DMX
DMX DMXNETWORK
SINGLE PHASE, 2 WIRE + GND
120V / 60Hz.
20A MAX.
(BY OTHERS)
8-PORT SIMPLE
NETWORK BOX
NETWORK
ECHOTOUCH STANDALONE DMX WITH UNISON FOUNDRY
ECHOTOUCH
PS435 24V DIN-RAIL MOUNT
POWER SUPPLY
1Ø, 2 WIRE + GND
120V / 60 Hz.
20A MAX.
(BY OTHERS)
24VDC DMX DMX
CONTROLLER - ETS
UNISON FOUNDRY UFD
PHASE-ADAPTIVE DIMMER
To restore defaults:Signal LED Hold both buttons for 5 seconds
Green Solid = System OK Green Blinking = No DMX
To set DMX address:
Red Solid = Load Error
Use RDM or see user manual
Red Blinking = Overtemp
POWERMODESETSIGNAL
SINGLE PHASE, 2 WIRE + GND
120V / 60 Hz.
20A MAX.
(BY OTHERS)
UNISON FOUNDRY UFD
PHASE-ADAPTIVE DIMMER
To restore defaults:Signal LED Hold both buttons for 5 seconds
Green Solid = System OK Green Blinking = No DMX
To set DMX address:
Red Solid = Load Error
Use RDM or see user manual
Red Blinking = Overtemp
POWERMODESETSIGNAL
SINGLE PHASE, 2 WIRE + GND
120V / 60 Hz.
20A MAX.
(BY OTHERS)
Control Series
PS435 24V DIN-RAIL MOUNT
POWER SUPPLY
1Ø, 2 WIRE + GND
120V / 60 Hz.
20A MAX.
(BY OTHERS)
ECHO E-DVAC-C
CEILING MOUNT VACANCY SENSOR
DMX OUT PLUG-IN STATION
DMX 2 OUTPUT
ECPB-DMX OUT
DMX CABLE
COLORSOURCE PAR
LED INDOOR FIXTURE
ECHOTOUCH STANDALONE DMX WITH COLORSOURCE FIXTURES
ECHOTOUCH
CONTROLLER - ETS
24VDC DMX
EchoConnect
ECHO INSPIRE-E1104
CONTROL STATION
Zone1Zone
2
Zone
Zone
3
4
EchoConnect EchoConnect EchoConnectEchoConnect
ECHOTOUCH WITH ECHO PRODUCTS
ECHO E-SPS-DIN
1Ø, 2 WIRE + GND
120V / 60 Hz.
20A MAX.
(BY OTHERS)
24VDC
ECHOTOUCH
CONTROLLER - ETS
PHASE-ADAPTIVE DIMMER
SINGLE PHASE, 2 WIRE + GND
DMX CABLE
ECHO GEN2 ELVD
ZONE SPACE
Dim Phase
Dim Mode
Red Reverse
Red
Fluorescent
Green Forward
Green
Normal
Auto
Edit Fluorescent Turn-On Voltage:
-Hold Dim Mode for 5 sec
(until Amber LED)
-Push Dim Mode to increase
Turn-on voltage by 2%
-Push Dim Phase to decrease
Amber
120V / 60 Hz.
20A MAX.
(BY OTHERS)
Restore Defaults:
-Set ZONE and SPACE to 16
then hold both buttons for 10 sec
Turn-on voltage by 2%
-Hold Dim Mode for
5 sec to save (Red LED)
COLORSOURCE PAR
LED INDOOR FIXTURE
PHASE-ADAPTIVE DIMMER
SINGLE PHASE, 2 WIRE + GND
ECHO GEN2 ELVD
ZONE SPACE
Dim Phase
Dim Mode
Red
Reverse
Red
Fluorescent
Green
Forward
Green
Normal
Auto
Edit Fluorescent Turn-On Voltage:
-Hold Dim Mode for 5 sec
(until Amber LED)
-Push Dim Mode to increase
Turn-on voltage by 2%
-Push Dim Phase to decrease
Turn-on voltage by 2%
-Hold Dim Mode for
Amber
120V / 60 Hz.
20A MAX.
(BY OTHERS)
Restore Defaults:
-Set ZONE and SPACE to 16
5 sec to save (Red LED)
then hold both buttons for 10 sec
4 of 7
Page 5
EchoTouch ControllerETC
ECHOTOUCH
CONTROLLER - ETS
ECHO EDMXC (DIN)
1Ø, 2 WIRE + GND
120V / 60 Hz.
20A MAX.
(BY OTHERS)
ECHO E-SPS-DIN
DMX PLUG-IN STATION
ECPB-DMX
DMX 1 INPUT
DMX OUT PLUG-IN STATION
ECPB-DMX OUT
DMX 2 OUTPUT
DMX CABLE
COLORSOURCE PAR
LED INDOOR FIXTURE
DMX CABLE
COLORSOURCE PAR
LED INDOOR FIXTURE
DMX CABLE
DMXDMX
EchoConnect
24VDC
EchoConnect
24VDC
1Ø, 2 WIRE + GND
120V / 60 Hz.
20A MAX.
(BY OTHERS)
PS435 24V DIN-RAIL MOUNT
POWER SUPPLY
DMX OUT PLUG-IN STATION
ECPB-DMX OUT
DMX 2 OUTPUT
DMX CABLE
COLORSOURCE PAR
LED INDOOR FIXTURE
DMX CABLE
COLORSOURCE PAR
LED INDOOR FIXTURE
ECHOTOUCH
CONTROLLER - ETS
NET3 ONE-PORT
OUTPUT GATEWAY
ARCSYSTEM PRO
FOUR-CELL ROUND LUMINAIRE
ECHOTOUCH
CONTROLLER - ETS
ZONE SPACE
Dim Phase
Dim Mode
Auto
Amber
Forward
Green
Reverse
Red
Normal
Green
Fluorescent
Red
Edit Fluorescent Turn-On Voltage:
-Hold Dim Mode for 5 sec
Restore Defaults:
-Set ZONE and SPACE to 16
then hold both buttons for 10 sec
(until Amber LED)
-Push Dim Mode to increase
Turn-on voltage by 2%
-Push Dim Phase to decrease
Turn-on voltage by 2%
-Hold Dim Mode for
5 sec to save (Red LED)
ECHO GEN2 ELVD
PHASE-ADAPTIVE DIMMER
SINGLE PHASE, 2 WIRE + GND
120V / 60 Hz.
20A MAX.
(BY OTHERS)
ECHO INSPIRE-E1104
CONTROL STATION
Zone
3
Zone
4
Zone1Zone
2
ECHOTOUCH
CONTROLLER - ETS
1Ø, 2 WIRE + GND
120V / 60 Hz.
20A MAX.
(BY OTHERS)
ECHO E-SPS-DIN
ECHO E-DVAC-C
CEILING MOUNT VACANCY SENSOR
NET3 ONE-PORT
OUTPUT GATEWAY
ARCSYSTEM PRO
FOUR-CELL ROUND LUMINAIRE
ARCSYSTEM PRO
FOUR-CELL ROUND LUMINAIRE
ARCSYSTEM PRO
FOUR-CELL ROUND LUMINAIRE
~
TO ADDITIONAL
FIXTURES
~
TO ADDITIONAL
FIXTURES
ZONE SPACE
Dim Phase
Dim Mode
Auto
Amber
Forward
Green
Reverse
Red
Normal
Green
Fluorescent
Red
Edit Fluorescent Turn-On Voltage:
-Hold Dim Mode for 5 sec
Restore Defaults:
-Set ZONE and SPACE to 16
then hold both buttons for 10 sec
(until Amber LED)
-Push Dim Mode to increase
Turn-on voltage by 2%
-Push Dim Phase to decrease
Turn-on voltage by 2%
-Hold Dim Mode for
5 sec to save (Red LED)
ECHO GEN2 ELVD
PHASE-ADAPTIVE DIMMER
SINGLE PHASE, 2 WIRE + GND
120V / 60 Hz.
20A MAX.
(BY OTHERS)
EchoConnect
EchoConnect EchoConnect EchoConnectEchoConnect
24VDC
24VDC DMX
NETWORK
NETWORK
NETWORK
DMX
DMX DMX
DMX DMX
DMX
SINGLE PHASE, 2 WIRE + GND
120V / 60Hz.
20A MAX.
(BY OTHERS)
8-PORT SIMPLE
NETWORK BOX
1Ø, 2 WIRE + GND
120V / 60 Hz.
20A MAX.
(BY OTHERS)
PS435 24V DIN-RAIL MOUNT
POWER SUPPLY
DMX OUT PLUG-IN STATION
ECPB-DMX OUT
DMX 2 OUTPUT
DMX CABLE
COLORSOURCE PAR
LED INDOOR FIXTURE
DMX CABLE
COLORSOURCE PAR
LED INDOOR FIXTURE
ECHOTOUCH
CONTROLLER - ETS
24VDC DMX
ECHOTOUCH STANDALONE SACN WITH GATEWAYS AND GDS FIXTURES
Control Series
ECHO INSPIRE-E1008
CONTROL STATION
Preset1Preset
2
Preset3Preset
4
Preset5Preset
6
Preset7Preset
8
COLORSOURCE 20 CONTROL CONSOLE
ECHOTOUCH
CONTROLLER - ETS
EchoConnect EchoConnect
ECHO INSPIRE-E1008
CONTROL STATION
Preset1Preset
2
Preset3Preset
4
Preset5Preset
6
Preset7Preset
8
CONTROLLER - ETS
ECHOTOUCH
DMX CABLE
EchoConnect
24VDC
NET3 ONE-PORT
OUTPUT GATEWAY
NETWORK
NETWORK
ECHOTOUCH WITH SACN, DMX AND ECHOCONNECT DEVICES
ECHO E-SPS-DIN
1Ø, 2 WIRE + GND
120V / 60 Hz.
20A MAX.
(BY OTHERS)
8-PORT SIMPLE
NETWORK BOX
NET3 ONE-PORT
OUTPUT GATEWAY
NETWORK
SINGLE PHASE, 2 WIRE + GND
120V / 60Hz.
EchoConnect
24VDC
20A MAX.
(BY OTHERS)
ECHOTOUCH
CONTROLLER - ETS
DMX
NETWORK
ECHOTOUCH FOR DMX SNAPSHOT APPLICATIONS
DMX PLUG-IN STATION
DMX 1 INPUT
ECPB-DMX
ECHO E-SPS-DIN
1Ø, 2 WIRE + GND
120V / 60 Hz.
20A MAX.
(BY OTHERS)
EchoConnect
24VDC
ECHO EDMXC (DIN)
DMX OUT PLUG-IN STATION
ECPB-DMX OUT
DMXDMX
ARCSYSTEM PRO
FOUR-CELL ROUND LUMINAIRE
DMX
ARCSYSTEM PRO
FOUR-CELL ROUND LUMINAIRE
DMX DMX
DMX OUT PLUG-IN STATION
DMX 2 OUTPUT
ECPB-DMX OUT
8-PORT SIMPLE
NETWORK BOX
SINGLE PHASE, 2 WIRE + GND
120V / 60Hz.
20A MAX.
(BY OTHERS)
DMX 2 OUTPUT
DMX CABLE
DMX CABLE
ARCSYSTEM PRO
FOUR-CELL ROUND LUMINAIRE
DMX DMX
ARCSYSTEM PRO
FOUR-CELL ROUND LUMINAIRE
COLORSOURCE PAR
LED INDOOR FIXTURE
NET3 ONE-PORT
OUTPUT GATEWAY
COLORSOURCE PAR
LED INDOOR FIXTURE
~
TO ADDITIONAL FIXTURES
~
DMX
TO ADDITIONAL FIXTURES
DMX CABLE
ARCSYSTEM PRO
FOUR-CELL ROUND LUMINAIRE
DMX DMXNETWORK
DMX CABLE
COLORSOURCE PAR
LED INDOOR FIXTURE
~
COLORSOURCE PAR
LED INDOOR FIXTURE
TO ADDITIONAL FIXTURES
5 of 7
Page 6
EchoTouch ControllerETC
LARGE SYSTEM ECHOTOUCH INTEGRATION
Control Series
OPTIONAL NETWORK CONNECTION TO PARADIGM
ECHO EEB
ECHO EXPANSION BRIDGE
(DIN-RAIL MOUNT)
~
Network
EchoConnect
24VDC
PS435 24V DIN-RAIL MOUNT
POWER SUPPLY
24VDC
1Ø, 2 WIRE + GND
120V / 60 Hz.
20A MAX.
(BY OTHERS)
ECHO E-SPS-DIN
EchoConnect
24VDC
1Ø, 2 WIRE + GND
120V / 60 Hz.
20A MAX.
(BY OTHERS)
24VDC24VDC
EchoConnect
24VDC
EchoConnect
CEILING MOUNT VACANCY SENSOR
EchoConnect
24VDC
CEILING MOUNT VACANCY SENSOR
EchoConnect
24VDC
CEILING MOUNT VACANCY SENSOR
EchoConnect
24VDC
CEILING MOUNT VACANCY SENSOR
EchoConnect
24VDC
CEILING MOUNT VACANCY SENSOR
EchoConnect
24VDC
ECHO E-DVAC-C
ECHO E-DVAC-C
ECHO E-DVAC-C
ECHO E-DVAC-C
ECHO E-DVAC-C
ECHO INSPIRE-E1008
CONTROL STATION
Preset1Preset
2
EchoConnect EchoConnect
EchoConnect
EchoConnect EchoConnect
EchoConnect EchoConnect
EchoConnect EchoConnect
Preset3Preset
4
Preset5Preset
6
24VDC24VDC
Preset7Preset
8
ECHO INSPIRE-E1008
CONTROL STATION
Preset1Preset
2
Preset3Preset
EchoConnect
4
Preset5Preset
24VDC 24VDC
24VDC 24VDC
6
Preset7Preset
8
ECHO INSPIRE-E1008
CONTROL STATION
Preset1Preset
2
Preset3Preset
4
Preset5Preset
6
Preset7Preset
8
ECHO INSPIRE-E1008
CONTROL STATION
Preset1Preset
2
Preset3Preset
4
Preset5Preset
6
Preset7Preset
8
ECHO INSPIRE-E1008
CONTROL STATION
Preset1Preset
2
Preset3Preset
4
Preset5Preset
6
Preset7Preset
8
24VDC24VDC
24VDC24VDC
ECHOTOUCH
CONTROLLER - ETS
ECHOTOUCH
CONTROLLER - ETS
ECHOTOUCH
CONTROLLER - ETS
ECHOTOUCH
CONTROLLER - ETS
ECHOTOUCH
CONTROLLER - ETS
DMX
DMX
DMX
DMX
DMX
UNISON FOUNDRY UFD
PHASE-ADAPTIVE DIMMER
To restore defaults:Signal LED Hold both buttons for 5 seconds
Green Solid = System OK Green Blinking = No DMX
To set DMX address:
Red Solid = Load Error
Use RDM or see user manual
Red Blinking = Overtemp
POWERMODESETSIGNAL
SINGLE PHASE, 2 WIRE + GND
120V / 60 Hz.
20A MAX.
(BY OTHERS)
UNISON FOUNDRY UFD
PHASE-ADAPTIVE DIMMER
To restore defaults:Signal LED Hold both buttons for 5 seconds
Green Solid = System OK Green Blinking = No DMX
To set DMX address:
Red Solid = Load Error
Use RDM or see user manual
Red Blinking = Overtemp
POWERMODESETSIGNAL
SINGLE PHASE, 2 WIRE + GND
120V / 60 Hz.
20A MAX.
(BY OTHERS)
UNISON FOUNDRY UFD
PHASE-ADAPTIVE DIMMER
To restore defaults:Signal LED Hold both buttons for 5 seconds
Green Solid = System OK Green Blinking = No DMX
To set DMX address:
Red Solid = Load Error
Use RDM or see user manual
Red Blinking = Overtemp
POWERMODESETSIGNAL
SINGLE PHASE, 2 WIRE + GND
120V / 60 Hz.
20A MAX.
(BY OTHERS)
UNISON FOUNDRY UFD
PHASE-ADAPTIVE DIMMER
To restore defaults:Signal LED Hold both buttons for 5 seconds
Green Solid = System OK Green Blinking = No DMX
To set DMX address:
Red Solid = Load Error
Use RDM or see user manual
Red Blinking = Overtemp
POWERMODESETSIGNAL
SINGLE PHASE, 2 WIRE + GND
120V / 60 Hz.
20A MAX.
(BY OTHERS)
UNISON FOUNDRY UFD
PHASE-ADAPTIVE DIMMER
To restore defaults:Signal LED Hold both buttons for 5 seconds
Green Solid = System OK Green Blinking = No DMX
To set DMX address:
Red Solid = Load Error
Use RDM or see user manual
Red Blinking = Overtemp
POWERMODESETSIGNAL
DMX
DMX
DMX
DMX
DMX
~
TO ADDITIONAL DMX DEVICES
~
TO ADDITIONAL DMX DEVICES
~
TO ADDITIONAL DMX DEVICES
~
TO ADDITIONAL DMX DEVICES
~
TO ADDITIONAL DMX DEVICES
PS435 24V DIN-RAIL MOUNT
POWER SUPPLY
24VDC
1Ø, 2 WIRE + GND
120V / 60 Hz.
20A MAX.
(BY OTHERS)
EchoConnect
24VDC
EchoConnect EchoConnect
EchoConnect
CEILING MOUNT VACANCY SENSOR
EchoConnect
24VDC
CEILING MOUNT VACANCY SENSOR
EchoConnect
24VDC
CEILING MOUNT VACANCY SENSOR
EchoConnect
24VDC
ECHO E-DVAC-C
ECHO E-DVAC-C
ECHO E-DVAC-C
ECHO INSPIRE-E1008
CONTROL STATION
Preset1Preset
2
EchoConnect EchoConnect
EchoConnect EchoConnect
EchoConnect EchoConnect
Preset3Preset
4
Preset5Preset
6
24VDC
ECHO INSPIRE-E1008
CONTROL STATION
ECHO INSPIRE-E1008
CONTROL STATION
24VDC 24VDC
24VDC
Preset
Preset
7
8
Preset1Preset
2
Preset
Preset
4
3
Preset5Preset
6
24VDC24VDC
Preset7Preset
8
Preset1Preset
2
Preset3Preset
4
Preset5Preset
6
Preset7Preset
8
6 of 7
ECHOTOUCH
CONTROLLER - ETS
ECHOTOUCH
CONTROLLER - ETS
ECHOTOUCH
CONTROLLER - ETS
DMX
DMX
DMX
SINGLE PHASE, 2 WIRE + GND
120V / 60 Hz.
20A MAX.
(BY OTHERS)
UNISON FOUNDRY UFD
PHASE-ADAPTIVE DIMMER
To restore defaults:Signal LED Hold both buttons for 5 seconds
Green Solid = System OK Green Blinking = No DMX
To set DMX address:
Red Solid = Load Error
Use RDM or see user manual
Red Blinking = Overtemp
POWERMODESETSIGNAL
SINGLE PHASE, 2 WIRE + GND
120V / 60 Hz.
20A MAX.
(BY OTHERS)
UNISON FOUNDRY UFD
PHASE-ADAPTIVE DIMMER
To restore defaults:Signal LED Hold both buttons for 5 seconds
Green Solid = System OK Green Blinking = No DMX
To set DMX address:
Red Solid = Load Error
Use RDM or see user manual
Red Blinking = Overtemp
POWERMODESETSIGNAL
SINGLE PHASE, 2 WIRE + GND
120V / 60 Hz.
20A MAX.
(BY OTHERS)
UNISON FOUNDRY UFD
PHASE-ADAPTIVE DIMMER
To restore defaults:Signal LED Hold both buttons for 5 seconds
Green Solid = System OK Green Blinking = No DMX
To set DMX address:
Red Solid = Load Error
Use RDM or see user manual
Red Blinking = Overtemp
POWERMODESETSIGNAL
SINGLE PHASE, 2 WIRE + GND
120V / 60 Hz.
20A MAX.
(BY OTHERS)
DMX
DMX
DMX
~
TO ADDITIONAL DMX DEVICES
~
TO ADDITIONAL DMX DEVICES
~
TO ADDITIONAL DMX DEVICES
Page 7
DESCRIPTION
QTY.
ITEM DESIGNATION PART NUMBER
PARTS LIST
24V
ECHO
DMX
I.T.E.
E500197
100BASE-TX PD
ETHERNET
ECHOTOUCH CONTROLLER ETS 400mA @24VDC NEC CLASS 2, TYPE 1
(BOTTOM)
USB
PHYSICAL
DESCRIPTION
QTY.
ITEM DESIGNATION PART NUMBER
PARTS LIST
24V
ECHO
DMX
I.T.E.
E500197
100BASE-TX PD
ETHERNET
ECHOTOUCH CONTROLLER ETS 400mA @24VDC NEC CLASS 2, TYPE 1
(BOTTOM)
USB
Product Dimensions and Weights
MODEL HEIGHT WIDTH WEIGHT
in mm in mm lb kg
ETS-_ 4.88 124 7.28 85 1.75 .79
ECHOTOUCH CONTROLLER FLUSH-MOUNT
EchoTouch Controller ETC
Control Series
ECHOTOUCH CONTROLLER SURFACE-MOUNT
Corporate Headquarters n 3031 Pleasant View Rd, PO Box 620979, Middleton WI 53562 0979 USA n +1 608 831 4116 London, UK n Unit 26-28, Victoria Industrial Estate, Victoria Road, London W3 6UU, UK n +44 (0) 20 8896 1000 Rome, IT n Via Bruno Pontecorvo 10, 00012 Guidonia Montecelio, Roma, Italy n +39 06 32 111 683 Holzkirchen, DE n Ohmstrasse 3, 83607 Holzkirchen, Germany n +49 (80 24) 47 00-0 Hong Kong n Room 1801, 18/F, Tower 1 Phase 1, Enterprise Square, 9 Sheung Yuet Road, Kowloon Bay, Kowloon, Hong Kong n +852 2799 1220 Web n etcconnect.com n Copyright©2018 ETC. All Rights Reserved. All product information and specifications subject to change. 7186L1026 Rev A 08/18
7 of 7
Loading...