ETC® Installation Guide
(16) Cat5 inputs
EchoConnect - white/black
twisted wire connects
between the 6 position
connector on the tray and
the 2 position connector on
the power supply.
ESD ground wire with Faston
connects between tray and ESD
ground bar on the power supply
Unison® EchoConnect Cat5 Termination Tray
Overview
This EchoConnect Cat5 termination tray is intended for
installation on the rear panel of the Echo Rack Mount
Station Power Supply (E-SPM-RM).
6.25” (15.8cm)
included
Use this termination tray to facilitate termination of up to
16 runs of Category 5 (or equivalent) cable on the
EchoConnect communication bus.
The following supplies are included for installation
convenience:
• 6.25” (15cm) of 2 conductor black/white wire
• 11” (28cm) ESD ground with Faston connector
• 4 x mounting screws
• Six position screw terminal connector J3263-F (x1)
Mount Tray to Rear Panel
The termination tray installs to the rear panel of the Echo
Rack Mount Station Power Supply. Secure the
termination tray to the rear panel using the four mounting screws provided.
Terminate Wires
This termination tray, as well as the rear panel of the Rack Mount Station Power Supply are provided
with wire forms to secure wires with cable ties. Cable ties are not provided but highly recommended to
use in maintaining the wire bundles.
Terminations include:
• EchoConnect between this termination tray and the Echo Rack Mount Station Power Supply.
• Up to 16 runs of Category 5 (or equivalent) cable between this termination tray and Echo control
stations.
• ESD ground wires terminate to the ground bar on the rear panel of the station power supply. This
connection is required for all stations that are not installed entirely in grounded metal conduit.
11” (28cm)
included
EchoConnect Cat5 Termination Tray Installation Guide Page 1 of 2 Electronic Theatre Controls, Inc.
Corporate Headquarters
London, UK
Rome, IT
Holzkirchen, DE
Hong Kong Rm 1801, 18/F, Tower 1 Phase 1, Enterprise Square, 9 Sheung Yuet Road, Kowloon Bay, Kowloon, Hong Kong Tel +852 2799 1220 Fax +852 2799 9325
Service:
Web:
7186M2201
Unit 26-28, Victoria Industrial Estate, Victoria Road, London W3 6UU, UK Tel +44 (0)20 8896 1000 Fax +44 (0)20 8896 2000
Via Pieve Torina, 48, 00156 Rome, Italy Tel +39 (06) 32 111 683 Fax +44 (0) 20 8752 8486
(Americas) service@etcconnect.com
www.etcconnect.com
Rev A Released 2014-05
3031 Pleasant View Road, P.O. Box 620979, Middleton, Wisconsin 53562-0979 USA Tel +608 831 4116 Fax +608 836 1736
Ohmstrasse 3, 83607 Holzkirchen, Germany Tel +49 (80 24) 47 00-0 Fax +49 (80 24) 47 00-3 00
Copyright © 2014 ETC. All Rights Reserved. Product information and specifications subject to change.
(UK) service@etceurope.com (DE) techserv-hoki@etcconnect.com
ETC intends this document to be provided in its entirety.
(Asia) service@etcasia.com
![](/html/38/3860/3860d0737255a90cf570514f68115e452b382379cc2474d94c8ccf3cc584771d/bg2.png)
ETC Installation Guide
EchoConnect Cat5 Termination Tray
Connect CAT5 Inputs
Echo control stations installed for use with Category 5 control wire for the EchoConnect station bus are
supplied with an EchoConnect Cat5 Station Termination Kit. This termination kit includes an additional
set of instructions, insulation displacement connectors (IDC) and the Cat5 Cable Preparation for IDC
Termination Kit (ETC part number 4100A1013). The last station in the control run will not require use of
the second IDC connector provided in this IDC termination kit. Use the extra connector to terminate the
station data run to this termination tray.
Reference the termination information that is detailed in the Cat5 Cable Preparation for IDC Termination
Setup Guide (included with the station termination kit).
Step 1: Connect the prepared Cat5 cable to any of the 16 available Cat5 input receptacles on the
termination tray.
Step 2: Repeat for each EchoConnect station data run in the system.
Connect EchoConnect to the Station Power Supply
Step 1: Remove the six position screw connector from the termination tray.
Step 2: Strip 3/8” (9-10mm) from each wire on the provided white/black twisted pair.
Step 3: Insert the white wire into the data + terminal and the black wire into the data - terminal and
tighten the screws firmly onto each wire.
Step 4: Replace the connector to the board.
Step 5: Remove the two position screw connector from the rear panel of the Echo Rack Mount
Station Power Supply.
Step 6: Insert the white wire into the data + terminal and the black wire into the data - terminal and
tighten the screws firmly onto each wire.
Step 7: Replace the connector to the rear panel.
Connect ESD Ground
Step 1: Connect the ground wire (provided) with the Faston connector to the spade terminal on
the termination tray.
Step 2: Strip 3/8” (9-10mm) from the bare end of the ESD ground wire.
Step 3: Loosen a screw terminal on the ground bar located on the rear panel of the Echo Rack
Mount Station Power Supply.
Step 4: Insert the wire into the terminal then tighten the screw firmly onto the wire.
EchoConnect Cat5 Termination Tray Installation Guide Page 2 of 2 Electronic Theatre Controls, Inc.