ETC E243ML-PACKAGE Quick Start Guide

Page 1
Unison Echo Products
Quick Info Guide
visual environment technologies | etcconnect.com
Page 2
Echo Control Products
Inspire 1 Button Inspire 2 Button Inspire 4 Button Inspire 6 Button Inspire 8 Button
EchoConnect: 1 - Control
Aux Power: Not required
Inspire 4 Btn Fader
EchoConnect: 1 - Control
Aux Power: Not required
Dual Tech 2 Button
EchoConnect: 1 - Control
Aux Power: Not required
EchoConnect: 1 - Control
Aux Power: Not required
EchoConnect: 1 - Control
Aux Power: Not required
EchoConnect: 1 - Control
Aux Power: Not required
5 Button Preset 10 Button Preset Lockout Station Dual Tech 1 Button
EchoConnect: 1 - Control
Aux Power: Not required
PIR Occupancy
Vacancy Sensor
EchoConnect: 1 - Control
Aux Power: Not required
Light Sensor
EchoConnect: 1 - Control
Aux Power: Not required
Ceiling Sensor
EchoConnect: 1 - Control
Aux Power: Not required
Dual Tech Wall
Sensor
EchoConnect: 1 - Control
Aux Power: Not required
EchoAccess
Interface
EchoConnect: 1 - Control*
Aux Power:
*see FAQs on page 4
-
50 mA
EchoConnect: 1 - Control
Aux Power: Not required
®
TimeClock
EchoConnect: 1 - Control
Aux Power:
-
40 mA
EchoConnect: 1 - Control
Aux Power: Not required
Input
EchoConnect: 1 - Control
Aux Power:
-
40 mA
EchoConnect: 1 - Control
Aux Power: Not required
Demand Response
Interface
EchoConnect: 1 - Control
Aux Power:
-
40 mA
EchoConnect: 1 - Control
Aux Power: Not required
BACnet InterfaceContact Interface
EchoConnect: 1 - Control
Aux Power:
-100 mA or PoE
1
Page 3
Echo Output Products
1 Zone Relay
Controller Gen2
EchoConnect: 1 - Output
Aux Power: Not required
# Of Spaces: 1
# Of Presets: 16
120V Phase
Adaptive Dimmer
Gen2
EchoConnect: 1 - Output
Aux Power: Not required
# Of Spaces: 1
# Of Presets: 16
2 Zone Relay
Controller Gen2
EchoConnect: 1 - Output
Aux Power: Not required
# Of Spaces: 1
# Of Presets: 16
277V Phase
Adaptive Dimmer
Gen2
EchoConnect: 1 - Output
Aux Power: Not required
# Of Spaces: 1
# Of Presets: 16
1 Zone 0-10V
Controller Gen2
EchoConnect: 1 - Output
Aux Power: Not required
# Of Spaces: 1
# Of Presets: 16
4 Zone Room
Controller Gen2
EchoConnect: 1 - Output
Aux Power: Not required
# Of Spaces: Max 4
# Of Presets: 16
2 Zone 0-10V
Controller Gen2
EchoConnect: 1 - Output
Aux Power: Not required
# Of Spaces: 1
# Of Presets: 16
8 Zone Room
Controller Gen2
EchoConnect: 1 - Output
Aux Power: Not required
# Of Spaces: Max 8
# Of Presets: 16
1 Zone SmartSpace
Controller Gen2
EchoConnect: 1 - Output
Aux Power: Not required
# Of Spaces: 1
# Of Presets: 16
4 Zone Room
Controller w/ TC
Gen2
EchoConnect: 1 - Output
Aux Power: Not required
# Of Spaces: Max 4
# Of Presets: 16
2 Zone SmartSpace
Controller Gen2
EchoConnect: 1 - Output
Aux Power: Not required
# Of Spaces: 1
# Of Presets: 16
8 Zone Room
Controller w/ TC
Gen2
EchoConnect: 1 - Output
Aux Power: Not required
# Of Spaces: Max 8
# Of Presets: 16
DRd With Echo Echo Relay Panel
Feedthrough
EchoConnect: 1 - Output
Aux Power: Not required
# Of Spaces: Max 16
# Of Presets: 64
EchoConnect: 1 - Output
Aux Power: Not required
# Of Spaces:
# Of Presets:
Max
Echo Relay Panel
Mains Feed
EchoConnect: 1 - Output
Aux Power: Not required
16
# Of Spaces:
4
6
# Of Presets:
Max
6
16
4
SensorIQ Sensor3 EchoDIN CE
(CE Projects Only)
EchoConnect: 1 - Output
Aux Power: Not required
# Of Spaces:
# Of Presets:
Max
6
Contact Output InterfaceDMX Scene Controller Echo-Echoflex Interface
EchoConnect: 1 - Output
Aux Power: Not required
16
# Of Spaces: Max 16
4
# Of Presets: 64
EchoConnect: 1 - Output
Aux Power: Not required
# Of Spaces:
# Of Presets:
EchoTouch Controller
Max
6
16
4
EchoConnect: 1 - Output
Aux Power:
# Of Spaces: 1
# Of Presets: 16
150 mA
-
EchoConnect: 1 - Output
Aux Power:
# Of Spaces: 1
# Of Presets: 16
50 mA
-
EchoConnect: 1 - Output
Aux Power:
# Of Spaces: 1
# Of Presets: 16
40 mA
-
EchoConnect: 1 - Output
Aux Power:
# Of Spaces: 1
# Of Presets: 64
-400 mA or PoE
2
Page 4
Echo Power Supplies
E-SPS E-APS
(Aux Power Only)
Provides:
Control 6
Output: 6
Aux Power: None
Aux Power:
E-SPM E-SPM-A
Provides
Control None
Output: None
+160 mA
Room Controller
Provides:
Control 6
Output: 5
Aux Power:
*For use with optional
installed TimeClock
40 mA*
+
E-SPM-WM
Echo Control
Processor
Provides:
Control 6
Output: 5
Aux Power: None
E-SPM-WM-A
CEM3
Provides:
Control 6
Output: 5
Aux Power: None
E-SPM-RM
E-SPS-DIN
Provides:
Control 16
Output: 16
Aux Power:
E-SPM-RM-A
+1500 mA
Provides:
Control 16
Output: 16
Aux Power: None
Provides:
Control 16
Output: 16
Aux Power:
+
1500 mA
Provides:
Control 16
Output: 16
Aux Power: None
Echo Expansion Bridge
EchoConnect: Does Not Count
Aux Power: 100 mA or PoE
The Echo Expansion Bridge provides three functions:
-Provide a wireless connection for the EchoAccess mobile app through a connected Wireless Access Point (WAP).
-Combine up to four EchoConnect Power Supples to create larger Echo control systems.
-Facilitates communication between Echo and Paradigm, allowing Paradigm to control Echo and Echo to tell Paradigm it’s status.
Provides:
Control 16
Output: 16
Aux Power:
Segment 1
1 Power
Supply
Max 16U
+1500 mA
Segment 2
1 Power
Supply
Max 16U
Provides:
Control 16
Output: 16
Aux Power: None
System:
Segment 3
1 Power
Supply
Max 16U
Provides:
Control 16
Output: 16
Aux Power:
Segment 4
1 Power
Supply
Max 16U
+1500 mA
3
Page 5
Echo Frequently Asked Questions
Q: What Does a Distributed System mean?
In Echo control systems all of the intelligence is
A:
share between all of the interconnected devices instead of a centralized control processor. For example, this means that each Output Device stores its own preset information and sends it’s status information out to the rest of the connected devices.
Q: EchoConnect power supplies are
measured in “U”s. What’s a “U”?
A: A “U” is a unit of power measurement. A unit
counts as one control product and one output product. For example, a 6U power supply would power 6 control products and 6 output products.
Q: When should I use a 6U vs a 16U
power supply?
A: If you have more than 6 control products
(stations, sensors, access, etc.) or more than 6 output products (zone controllers, panels, DMX Scene, etc.)
Q: Do I have to use ETC’s 24V Aux for
auxiliary Power?
A: No. Any 24 volt power supply will work. It is not
required to be provided by ETC but it is required by the products.
Q: What does it mean that EchoAccess is a
bonus power-wise?
A: The first EchoAccess in a system does not count
against your power supply count. So you can have 7 stations on a 6U power supply if one is an EchoAccess station.
Q: Can I use more than one power supply?
Without an Expansion Bridge, no. Only one power
A:
supply may be used at a time. Output products that also have power supplies in them have the option to have the power supply turned off.
Q: What if I need more than 16 stations?
Q: When do I need Aux power?
If you have a TimeClock, EchoAccess, DMX Scene
A:
Controller, Echo-Echoflex Interface, Echo Contact Interface, BACnet Interface, Echo Expansion Bridge or EchoTouch you need an Aux power unit.
Q: Do I have to use ETC’s EchoConnect
Station Power Supplies?
A: Yes. An EchoConnect power supply is required in
all Echo systems and are only available from ETC.
Corporate Headquarters n 3031 Pleasant View Rd, PO Box 620979, Middleton WI 53562 0979 USA n +1 608 831 4116 London, UK n Unit 26-28 Victoria Industrial Estate, Victoria Road, London W3 6UU, UK n +44 (0) 20 8896 1000 Rome, IT n Via Pieve Torina, 48, 00156 Rome, Italy n +39 (06) 32 111 683 Holzkirchen, DE n Ohmstrasse 3, 83607 Holzkirchen, Germany n +49 (80 24) 47 00-0 Hong Kong n Room 1801, 18/F, Tower 1 Phase 1, Enterprise Square, 9 Sheung Yuet Road, Kowloon Bay, Kowloon, Hong Kong n +852 2799 1220 Web n etcconnect.com n Copyright©2017 ETC. All Rights Reserved. All product information and specifications subject to change. 07/18
Add an Echo Expansion Bridge! That will give you
A:
a new max of 64U. But remember, you’ll still need power supplies to account for all the products.
4
Loading...