It’s our FEATURES
Water Trough - Adjustable for even water distribution
Motor - Water Resistant with thermal overload
protection and permanently lubricated bearings
Cabinet - Heavy gauge galvanized steel. Bolts
together for easy access and rust/corrosion resistence
Blower - Machine balanced for smooth, quiet
operation and maximum air delivery
*
Essick Excel
Pump - Permanently lubricated bearings can run
with or without water
Built-in leveling leg - Window units include
house legs for leveling and extra support
* Except for N28W unit
8
Year Limited
Warranty
on bottom pan
against leakage
due to rust-out.
that set our coolers above the rest
Selecting the right Essick cooler is EASY
1. Consult zone map to find correct size.
2. Consult table below to find correct “minutes per air change” for your zone.
3. Determine area to be cooled in cubic feet (building height x length x width.)
4. Divide cubic feet from step three by minutes per air change (step 2) to determine CFM.
5. Select correct Essick Cooler model in the specifications table according to CFM and expected static pressure.
Residential Evaporative Coolers
The Environmentally Friendly
Alternative To Traditional
Air Conditioning
IF CFM falls between models, choose the larger model.
Minutes Per Air Change
INTERIOR
HEAT LOAD
HIGH EXPOSED 2 1.5 1.3 .7
HIGH 3 2 1.5 1INSULATED
NORMAL EXPOSED 3 2 1.5 1
NORMAL INSULATED 4 3 2 1.3
For Example:
A house in Phoenix AZ. is 40 ‘ long by 30 ’ wide with 8‘ ceilings and has standard insulation with no unusual heat sources.
1. Establish cubic feet: 30 x 40 x 8 = 9,600 cu. ft. 2. Determine Zone: Phoenix is in Zone 2
3. Use chart to discover Minutes Per Air Change: 3 4. Compute Cubic Feet per Minute (CFM): 9,600÷3 = 3,200 CFM
5. Review Specification Charts inside brochure to determine which unit meets the needs.
In th
is example, the N43/48D with ½ h. p. motor i
Essick Air Products 5800 Murray Street , Little Rock, AR. 72209 800 643-8341 www.essickair.com
EXTERIOR
HEAT LOAD
ZONE
1
234
s indicated (assuming a typical static pressure of 0.2).
Interior Heat Load: High means places with unusual heat
sources from hot equipment or processes, crowded conditions, etc.
Normal means no unusual heat sources - typical home or office.
Exterior Heat Load: Exposed means walls and/or roof exposed to sun,
poor insulation, etc.
Insulated means walls and roof well insulated and/or shaded.
N- Series
Coolers Provide
A Wide Variety of
Home Cooling Options:
• Window Units
• Remote Controlled Units
• Down Discharge Units
• Side Discharge Units
ALL UNITS MADE IN USA
ERB 06-08
ADVANTAGES
of Essick Air Evaporative Coolers
Essick Air coolers oer:
Low Maintenance Features
• One piece bottom pan for rust resistance
In this day of escalating energy costs and environmental concerns,
the advantages of installing Evaporative Coolers grow every year.
Our innovative engineering and quality workmanship ensures high efficiency
performance, low maintenance, cost effectiveness and environmental responsibility.
SIDE
DISCHARGE
D
FRONTSIDEREAR
C
G
FF E
J
A
Match letters on the Window Unit illustration at far right to dimensions in table above.
I
• Tough polyester finish inside & out to resist rust & impact
• Bolted construction for easy access and maintenance
Low Operating Costs
• Uses less energy than air conditioning
• Uses water instead of chemicals for cooling
Units with (R) indicate this model is available with remote control.
*
WINDOW
B
E
G
A
UNITS
C
TOP
B
FRONT
J
WINDOW UNIT DIMENSION IDENTIFIER VIEWS
D
A
H
B
DOWN
DISCHARGE
I
H
DRAIN
Match letters on the Side Discharge illustration at top left to dimensions in table above.
C
D
G
F
DUCTED UNIT DIMENSION IDENTIFIER VIEWS
F
E
A
B
J
H
A
F
I
K
SIDE
w
U
o
n
d
i
n
i
W
W
i
t
h
C
o
t
s
e
l
l
i
r
G
n
e
l
v
b
e
i
t
r
Most of our window units
*
can be installed horizontally
in standard windows or
vertically between wall studs.
A handy remote control comes
with the RN35W, RN46W, and
RN50W models.
SIDE FRONT BOTTOM
A
Window units are shipped fully
assembled. Motors on window
units are mounted and tested
C
Match letters on the Down Discharge illustration at left to dimensions in table above.
All motors have automatic overload.
* CFM = Cubic Feet per minute
before shipment.
Motors shipped separately on Side and Down Discharge units.