Essick Air MA0800, MAF2 User Manual

READ AND SAVE THESE INSTRUCTIONS
COMFORT IS IN THE AIR
Français …......13
1B72771 4/2014 PRINTED IN CHINA
MINI-CONSOLE
EVAPORATIVE HUMIDIFIER
MODEL MA0800
Adjustable Humidistat Three Speed Fan
Easy Bottle Fill
TO ORDER PARTS AND ACCESSORIES CALL 1.800.547.3888
Español …….. 25
IMPORTANT SAFEGUARDS
2

General Safety Instructions

READ BEFORE USING YOUR HUMIDIFIER

DANGER: means if the safety information is not followed someone will be seriously injured or killed.

WARNING: means if the safety information is not followed someone could be seriously injured or killed.

CAUTION: means if the safety information is not followed someone may be
injured.
1. To reduce the risk of fire or shock hazard, this humidifier has a polarized plug (one blade is wider than the other). Plug humidifier directly into a 120V, A.C. electrical outlet. Do not use extension cord s. If the plug does not fully fit into the outlet, reverse plug. If it still does not fit, contact a qualified electrician to install the proper outlet. Do not change the plug in any way.

2. Keep the electric cord out of traffic areas. To reduce the risk of fire hazard, never put the electric cord under rugs, near heat registers, radiators, stoves or heaters.

3. Always unplug the unit before moving, cleaning or removing the fan assembly section from the humidifier, or whenever it is not in service.

4. Keep the humidifier clean. To reduce the risk of injury, fire or damage to
humidifier, use only cleaners specifically recommended for humidifiers. Never use flammable, combustible or poisonous materials to clean your humidifier.

5. Do not put foreign objects inside the humidifier.

6. Do not allow unit to be used as a toy. Close attention is necessary when used by or near children.

7. To reduce the risk of electrical hazard or damage to humidifier, do not tilt, jolt or tip humidifier while unit is running.

8. To reduce the risk of accidental electrical shock, do not touch the cord or controls with wet hands.

9. To reduce the risk of fire, do not use near an open flame such as a candle or other flame source.

WARNING: For your own safety, do not use humidifier if any parts are
damaged or missing. WARNING: To reduce risk of fire, electric shock, or injury always unplug
before servicing or cleaning. WARNING: To reduce the risk of fire or shock hazard, do not pour or spill
water into control or motor area. If controls get wet, let them dry completely and have unit checked by authorized service personnel before plugging in.
INTRODUCTION
the certification of output and may void your warranty.
Description
MA0800
*Output per 24 hrs
8 gallons/30.2 Litres
Capacity of Bottle
1.2 gallons/4.54 Litres
Capacity of Base
1.2 gallons/4.54 Litres
2500 (Tight Const.)
1700 (Avg. Const.)
Fan Speeds
3
Replacement Wicking Filter
MAF2
Adjustable Humidistat
Yes
Refill Indication
Yes
Controls
Digital
Rubber feet
Yes (6)
ETL Listed
Yes
Volts
60
Hertz ( High Speed)
1.2
Amps (High Speed)
81
Your new humidifier adds invisible moisture to your home by moving dry inlet air through a saturated wick. As air moves through the wick, the water evaporates into the air, leaving behind any white dust, minerals, or dissolved and suspended solids. Because the water is evaporated, there is just clean and invisible moist air.
As the evaporative wick traps accumulated minerals from the water, its ability to absorb and evaporate water decreases. We recommend changing the wick at the beginning of every season. In hard water areas, more frequent replacement may be necessary to maintain your humidifier’s efficiency.
Use only AIRCARE® or Essick Air® brand replacement wicks and chemicals. To order parts, wicks and chemicals call 1-800-547-3888. The MA0800 humidifiers use wick # MAF 2. Only the AIRCARE guarantees the certified output of your humidifier. Use of other brands of wicks voids
HOW YOUR HUMIDIFIER WORKS
Dry air is drawn into the sides of the humidifier, then air is moisturized as it passes through the saturated evaporative wicking filter in the reservoir.
The humidified air is then released through top of the unit.
®
or Essick Air® /MoistAIR® evaporative wick
* Based on an area with average insulation and an 8’ ceiling
height ANSI/AHAM HU-1-1997. SEC. 8.1. Results may vary.
Sq. ft. coverage
3
NOTES ON LOCATION:
In order to get the most effective use from your humidifier, it is important to p
osition
the unit throughout the house such as near a cold air return. If the window, condensation may form on the window pane. If this occurs the unit should be repositioned in another location.
ASSEMBLY
1)
2)
packaging:
Evaporative wicking filter
Manual
WATER FILL
CAUTION: Before filling, ensure unit is turned OFF. Keep grille dry at all times.
WARNING
into control or motor area. If controls get wet, let them dry completely and have unit checked by authorized service personnel before plugging in.
After the humidifier is positioned where it will be operating you are ready to fill the humidifier. The bottle lifts straight up and away from the base. Take care not to bump or damage fill valve assembly on the bott
Invert the bottle. Press the valve stem button into the bottle and turn clockwise to lock in open position. Place bottle under the faucet. Fill the bottle, being careful not to allow any debris to get in the bottle. Debris may interfere w seating. Once the bottle is full, press the valve stem button and turn counter clockwise to release and close.
a.
b.
c.
where the most humidity is needed or where the moist air will be circulated
unit is positioned close to a
Do NOT position the unit directly in front of a hot air duct or radiator. Do NOT place on soft carpet.
Due to the release of cool, moist air from the humidifier, it is best to direct air away from thermostat and hot air registers. Position humidifier next to an inside wall on a level place at least 4 inches away from the wall or curtains.
Unpack humidifier from carton. Remove all packaging materials. Check to see that you have all of the following
items removed from the box, accessory kit and cabinet before discarding the
: To reduce the risk of fire or shock hazard, DO NOT pour or spill water
om of the bottle.
ith the valve
4
CAUTION:
Use only EPA Registered Bacteriostat. Under no circumstances should
you use Water Treatment humidifiers.
NOTE:
1970 when you refill the water reservoir to eliminate bacterial growth. Add bacteriostat according to the instructions on
Place the water bottle back into the humidifier base. plunger will open and the contents of the water process. let the
ABOUT HUMIDITY
Where you set your desired humidity levels dep the
NOTE
reduced at levels of 43% humidity. You may wish to purchase a hygrometer* to measure the
home. The following is a chart of recommended humidity settings.
°F ° C
Humidity (RH) is
-20
15 - 20%
*Model 1990 digit al hygrometer is available for purchase by cal ling 1
NOTE:
levels can vary significantly even in one room.
OPERATION
Plug cord should be placed at least FOUR inches away from any walls and away from heat registers. Unrestricted airflow into the unit will result in the best efficiency and performance.
This level around the immediate area of the humidifier. It causes the humidifier to cycle on and off to maintain the selected humidity humidit until a reading of 1% above the
exceed 50%.
products intended for Rotobelt or Ultrasonic
We recommend using AIRCARE® or Essick Air® Bacteriostat Treatment PN
the bottle.
When positioned properly, the
water will flow into the base. The base will hold the entire
bottle. Once the bottle is empty, remove it and repeat the filling
The humidifier is now filled to capacity. To benefit from less frequent filling
humidifier exhaust both the water from the bottle and t he base befor e fi lli ng.
ends on your personal comfort level,
outside temperature and the inside temperature.
: Recent CDC tests show that the chances of flu transmission are greatly
humidity level in your
IMPORTANT: Water damage may result if condensation starts to form on windows or walls. Humidity SET point should be lowered until condensation no longer forms. We recommend room humidity levels do not
External hygrometer readings and humidistat readings may differ. Humidity
When Outdoor
Temperature is:
-10° 2° 10° 20° 30°
-24°
-18°
-12°
-6°
-1°
-800-547-3888.
Recommended Indoor Relative
20 - 25% 25 - 30% 30 - 35% 35 - 40% 40 - 45%
into wall receptacle. Your humidifier is now ready for use. The humidifier
unit has an automatic humidistat located in the cord that senses the humidity
SET point. The fan will turn on when the
y reading falls 3% below the SET point and will continue to run the humidifier
SET point is achieved.
5
CONTROL PANEL
Digital Display
Press the power button once to turn the unit on*. Initially there is a slight while the electronics calibrate. Two bars ( Once calibration is complete a R humidity reading between 20% be displayed. A flashing 20 display indicates that the room humidity is less than 20%.
NOTE: SET
as the unit remains plugged in and there is no power interruption. When the unit is unplugged, the
* Humidifier fan should operate at initial start up. If it does not, refer to “Fan not operating (digital display is illuminated n Trouble Shooting Table.”
HUMIDITY SETTING
This button allows you to adjust the humidity to suit your needs. This humidifier will automatically cycle on and off as required to maintain the selected setting.
The readout displays both actual settings when humidity control button is pre 20% to 95% Relative Humidity (RH). If the room humidity level is equal to or less than 20% RH the display will show a flashing 20. The 65% RH and is adjusted in increments of 5%. Initi will display the current humidity setting. Each additional press of the button increases the setting by 5%. A regardless of the on the power cord. Insure that it is free from obstruction.
FAN SPEED
This humidifier is equipped with a 3 fan control. Initially depressing the speed button will display the current speed setting. advances the
(HIGH) F3, (MEDIUM) F2 and (LOW) F1.
The selected setting is displayed on the digital readout. The higher the setting, the faster water is evaporated and released into the air. setting and is provided for conditions that do not r
NOTE: When excessive condensation exists, a lower speed setting is recommended.
delay
- -) appear during this time.
The default settings at initial startup are (LOW) F1 fa n speed and 65%
humidity. After desired settings are selected by the user, they remain as long
original default settings are reinstated.
.
Each push of the speed button
SET point of 65% RH operates the humidifier continuously
ROOM reading. The humidistat that senses the readings is located
mode through the settings of
OOM
- 95% will
(ROOM) and desired (SET) humidity percentage (%)
ssed. The ROOM readout has a range of
SET readout has a range of 25% to
ally depressing the humidity button
-speed
F1 (LOW) is the quietest
equire a rapid evaporation rate.
6
REFILL INDICATION
When both the bottle and the base are empty, the display alternates the room humidity reading and
(FILL)
At this time and refill unit according to the instructions in the WATER FILL section.
, indicating additional water is required.
CHECK FILTER INDICATOR
The ability of any humidifier to efficiently supply humidity output relies heavily on the condition of the filter. As the wicking filter loads with impurities it gradually loses its wicking capability. When this happens, moisture output is reduced and the humidifier has to work longer to satisfy the selected setting.
This humidifier has a check filter reminder timed to appear after 720 hours of operation. When the display shows an alternating “CF” and “room humidity” setting at 5 second intervals it is a reminder to check the filter condition.
NOTE: Some areas have high water mineral content causing the need for more Frequent wicking filter changes.
Reset the Check Filter “CF” function each time you replace a filter by unplugging the unit from the power source, then plug it in again.
Refer to REPLACEMENT OF WICKING FILTER if a build-up of deposits or severe discoloration is evident replace the to restore maximum efficiency.
REPLACEMENT OF WICKING FILTER
CAUTION: Before changing wicking filter, ensure unit is turned OFF. CAUTION: To help prevent bacteria growth
and keep maximum efficiency, the wicking filter should be replaced at least once per season, or more often under hard water conditions. Use AIRCARE /MoistAIR® MAF2 replacement wicking filter.
Replace the evaporative wicking filter at least once per humidification season or more depending on water conditions in your area.
Wicking Filter Replacement
1. Unplug humidifier. Before removing the filter, we recommend moving the humidifier to an area where floor coverings are not susceptible to water damage (i.e. kitchen or bath areas.)
2. Remove the water bottle and set aside. Be sure not to bump or damage the fill valve.
®
/Essick
®
7
3. Grasp the housing assembly and lift straight up and away from the base
and set aside. The wicking filter is now accessible.
4. Take note of the filter position.
5. Ins
6. Return the housing assembly to the top of the base. Reposition the humidifier to its operating position.
cleaners on the wick. Leave in sink to drain.
REMOVING SCALE
4) Install new filter at beginning of season.
Remove the filter. You may want to clean the base at this time. See the "Care and Maintenance" section of this manual.
tall a new wicking filter (MAF2) into the base. Coil the filter and position it between the uprights in the bottom of the base. The start and finish of the coil should be captured at the center of the base (see diagram) and the filter should be resting on the floor of the base.
CARE AND MAINTENANCE
Cleaning your humidifier reg ul arly helps eliminate odors and bacterial and fungal growth. Ordinary household bleach is a good disinfectant and can be used to
wipe out the humidifier base and bottle/reservoir after cleaning. We recommend cleaning your humidifier at least once every two weeks to maintain optimum environmental conditions for your home. We also recommend using AIRCARE® or
Essick Air® Bacteriostat Treatment each time you refill your humidifier to eliminate bacterial growth. Add bacteriostat according to the instructions on the
bottle. Please call 1-800-547-3888 to order Bacteriostat Treatment, PN 1970 or wicks.
1) Turn off unit completely and unplug from outlet.
2) Lift off the chassis.
3) Carry the base to cleaning basin. Lift wick from the base allowing the water to drain. Rinse wick under freshwater only. Do not use soap, detergent, or any other
4) Pour out any remaining water from the unit. Fill base and bottle ½ full with water and add 8 oz. (1 cup) of undiluted white vinegar. Let stand 20 minutes.
5) Dampen a soft cloth with white vinegar and w ipe out reservoir to remove scale. Rinse the water bottle and base thoroughly with fresh water to remove scale and cleaning solution before disinfecting.
DISINFECTING UNIT
6) Fill the bottle and base ½ full with water and add 1 teaspoon of bleach. Let solution stay for 20 minutes, then rinse with water until bleach smell is gone. Dry interior surfaces with clean cloth. Wipe down the outside of the unit with a soft cloth dampened with fresh water.
7) Refill unit and reassemble per ASSEMBLY instructions.
SUMMER STORAGE
Clean unit as outlined in Care & Maintenance section.
1)
2) Discard used wick and any water in the bottle or base. Allow to dry thoroughly
before storage. Do not store with water inside unit.
3) Do not store unit in an attic or other high-temperature area, as damage is probable.
8

REPAIR PARTS LIST

ITEM NO.
DESCRIPTION
MA0800 PART NO.
1
1B72774
Top Assembly
2
MAF2
† Filter
3
831188-1
Support, Float
4
831189
Float, Reservoir
5
831187-1
Base
6
831190
Foot, Rubber
7
831199
Bottle Assembly
8
831207
Cap, Screw
9
1B72771
Owner’s Manual (not shown)

Order by part number, not by item number. T o order, ca ll: 1-800-547-3888

† Stock item - Purchase locally or call 1-800-547- 3888 from the
USA or 1-888-744-4689 from Canada to order.
• Any attempt to repair the control assembly or motor voids the warranty and may create a hazard unless repair is done by a qualified service technician.
To order parts, call: USA 1-800-547 3888 or in Canada: 1-888-744-4687
9

TROUBLESHOOTING GUIDE

Trouble
Probable Cause
Remedy
• No Power.
• Power button has not been
depressed.
• Check 120 volt power source.
Fan not operating
ROOM humidit y level is not
• Reservoir is empty.
• Raise SET humidity level if desired.
• A SET humidity percentage of 65%
may t ake up to 48 hours initially.
• Mineral buildup on
• Change to a fresh new wicking
more rapidly in the wicking filter.
completely
• This is normal for initial
filling
• Refill bottle for maximum run time.
• Air is entering water bottle.
• Check for leak in water bottle.
debris.
• Spring Valve Assembly
• Base full of water.
• Check position of b ottle.
from base.
is clearly reduced.
• Loss of power or a power
humidifier is plugged in.
• Normal
• Reservoir is empty.
Digital display not illuminated.
(digital display is illuminated).
Fan running continuously.
Poor evaporation of water.
Bottle empt ies
Bottle continues to empty after complete filling.
Bottle not emptying.
3% or more below SET humidity level.
SET humidity level is 65%. ROOM humidity level has
not reached 1% or more above SET humidity level.
CHECK FILTER (CF) message flashing.
filter.
damaged or missing post in
bottom of base.
wicking
• Press power button once to turn on.
• Increase fan speed.
• Fill humidifier with water.
operates fan continuously. Adjust SET level between 25% - 60%.
• Continue to run until desired humidity level is achieved. This
filter.
• NOTE: Local water varies from area to area and under certain conditions minerals will build up
• Ensure fill valve position is turned to closed and valve has no inter fering
Reposition so that fill valve on bottom of bottle is depressed by post in bottom of base.
• The base will hold the contents of
water bottle (1.2gallons). Continue
to run humidifier to deplete water
“CF” message does not appear even when filter is dirty or humidifier performance
Display blinks or fan moves slightly when
Alternating “F” and room humidity displayed.
Alternating “CF” and room humidity displayed.
failure has caused the CF message to prematurely reset.
Wicking filter may be dirty. • Replace wicking filter.
10
• Replace wicking filter.
• No action required.
• Fill humidifier with water.
• Unplug unit for 30 seconds and replug in to clear display.
Loading...