Essick Air E35 000 User Manual

READ AND SAVE THESE INSTRUCTIONS
®
EVAPORATIVEHUMIDIFIER
MODELE35000
USEANDCAREGUIDE
AdjustableHumidistat TwospeedFan 
PourinFill
TOORDERPARTSANDACCESSORIESCALL1.800.547.3888
1B72855 10/2014 PRINTED IN CHINA
COMFORT IS IN THE AIR
Français ….........9
Español …….. ..17
IMPORTANT SAFEGUARDS General Safety Instructions
READ BEFORE USING YOUR HUMIDIFIER
DANGER: means if the safety information is not followed someone will be seriously injured or killed.
WARNING: means if the safety information is not followed someone could be seriously injured or killed.
CAUTION: means if the safety information is not followed someone may be injured.
1. To reduce the risk of fire or shock hazard, this humidifier has a polarized plug (one blade is wider than the other). Plug humidifier directly into a 120V, A.C. electrical outlet. Do not use extension cords. If the plug does not fully fit into the outlet, reverse plug. If it still does not fit, contact a qualified electrician to install the proper outlet. Do not change the plug in any way.
2. Keep the electric cord out of traffic areas. To reduce the risk of fire hazard, never put the electric cord under rugs, near heat registers, radiators, stoves or heaters.
3. Always unplug the unit before moving, cleaning or removing the fan assembly section from the humidifier, or whenever it is not in service.
4. Keep the humidifier clean. To reduce the risk of injury, fire or damage to humidifier,
use only cleaners specifically recommended for humidifiers. Never use flammable, combustible or poisonous materials to clean your humidifier
5. Do not put foreign objects inside the humidifier.
6. Do not allow unit to be used as a toy. Close attention is necessary when used by or near children.
7. To reduce the risk of electrical hazard or damage to humidifier, do not tilt, jolt or tip humidifier while unit is running.
8. To reduce the risk of accidental electrical shock, do not touch the cord or controls with wet hands.
9. To reduce the risk of fire, do not use near an open flame such as a candle or other flame source.
WARNING: For your own safety, do not use humidifier if any parts are damaged
or missing. WARNING: To reduce risk of fire, electric shock, or injury always unplug before
servicing or cleaning. WARNING: To reduce the risk of fire or shock hazard, do not pour or spill liquid
into control or motor area. If controls get wet, let them dry completely and have unit checked by authorized service personnel before plugging in.
2
INTRODUCTION
Your new humidifier adds invisible moisture to your home by moving dry inlet air through a saturated wick. As air moves through the wick, the water evaporates into the air, leaving behind any white dust, minerals, or dissolved and suspended solids. Because the water is evaporated, there is just clean and invisible moist air.
As the evaporative wick traps accumulated minerals from the water, its ability to absorb and evaporate water decreases. We recommend changing the wick at the beginning of every season. In hard water areas, more frequent replacement may be necessary to maintain your humidifier’s efficiency.
Use only AIRCARE order parts, wicks and chemicals call 1-800-547-3888. This humidifier uses wick # SGL1040. Only the AIRCARE® or Essick Air® evaporative wick guarantees the certified output of your humidifier. Use of other brands of wicks voids the certification of output and may void your warranty.
HOW YOUR HUMIDIFIER WORKS
Your new evaporative humidifier is designed to satisfy home humidity requirements through the principle of evaporation of water in the air.
Once the wick becomes saturated, air is drawn in, passes through the wick and moisture is absorbed into the air. All evaporation occurs in the humidifier so any residue remains in the wick.
This natural process of evaporation creates no white dust like some other humidifiers.
*Output per 24 hrs 2.2 gallons Water capacity 1.2 gallons *Sq. ft. coverage Up to 800 (Tight Construction) Fan Speeds 2 Replacement Wick SGL1040 Hygrometer Yes Controls Analog ETL Listed Yes Volts 120 Hertz 60 Watts 60
*Based on an area with average insulation and an 8’ ceiling height.
NOTES ON LOCATION:
In order to get the most effective use from your humidifier, it is important to position the unit where the most humidity is needed or where the moist air will be circulated throughout the house such as near a cold air return. If the unit is positioned close to a window, condensation may form on the window pane. If this occurs the unit should be repositioned in another location.
Do NOT position the unit directly in front of a hot air duct or radiator. Do NOT place on soft carpet.
®
or Essick Air® brand replacement wicks and chemicals. To
Air is drawn
in through
the vents
in the back
Humidified air is expelled out the
front louvers
Description E35000
3
Due to release of cool, moist air from the humidifier, it is best to direct air away from thermostat and hot air registers. Position humidifier next to an inside wall on a level place at least 4 inches away from the wall or curtains.
ASSEMBLY
1) Unpack humidifier from carton.
2) Remove all packaging materials, wick, etc. from box.
CHASSIS
ANALOG
HYGROMETER
HUMIDITY CONTROL
KNOB
FAN
SPEED
KNOB
BASE
1040 WICK
Replacement Parts Available For Purchase*
Description Part Number Chassis Base Wick Manual (not shown)
WATER FILL AND WICK REPLACEMENT
CAUTION: Before filling, ensure unit is turned OFF and unplugged. NOTE: Unit will continue running, even when out of water.
1) Lift chassis (top section) off base. Position wick in the notch at the back of the base.
2) Before replacing the chassis, fill the base with unsoftened water. DO NOT POUR WATER OVER THE ELECTRICAL CHASSIS. Fill the base (see illustration, next page) to the level marked “MAX FILL” on the center bottom of the base.
3) If water spills on the chassis, it must be allowed to dry completely before turning on the humidifier. If you have only softened water available in your home, you can use it, but you will notice a build up of minerals on the evaporative wick much sooner. Base capacity is 1.2 gallons. DO NOT OVERFILL.
1B72870 1B71891 SGL1040 1B72855
*Parts and accessories may be ordered by calling 1-800-547-3888, or visit www.essickair.com or www.AIRCAREproducts.com. Please have model number of humidifier available when ordering.
4
NOTE: We recommend using AIRCARE
®
or Essick Air® Bacteriostat Treatment when you refill the water reservoir to eliminate bacterial growth. Add bacteriostat according to the instructions on the bottle.
Under no circumstances should you use Water Treatment products intended for Rotobelt or Ultrasonic humidifiers.
REPLACEMENT OF WICK
CAUTION: Before changing wick, ensure unit is turned OFF and unplugged. NOTE: This unit uses model SGL1040 wick. Replace the wick at the beginning
of each season, and more often in areas with hard water.
1) To replace wick, lift off the chassis.
2) Remove the old wick and replace with a fresh wick.
ABOUT HUMIDITY
Where you set your desired humidity levels depends on your personal comfort level, the outside temperature and the inside temperature.
NOTE: Recent CDC tests show that the chances of flu transmission are greatly reduced at levels of 43% humidity.
You may wish to purchase a hygrometer* to measure the humidity level in your home. The following is a chart of recommended humidity settings.
IMPORTANT: Water damage may result if condensation starts to form on windows or walls. Humidity SET point should be lowered until condensation no longer forms. We recommend room humidity levels do not exceed 50%.
When Outdoor
Temperature is:
°F ° C
-20
-10° 2° 10° 20° 30°
-30°
-24°
-18°
-12°
-6°
-1°
Recommended
Indoor Relative
Humidity (RH) is
15 - 20% 20 - 25% 25 - 30% 30 - 35% 35 - 40% 40 - 45%
*Model 1990 digital hygrometer is available for purchase by calling 1-800-547-3888, or visit www.essickair.com or www.AIRCAREproducts.com.
5
NOTE: External hygrometer readings and humidistat readings may differ. Humidity levels can vary significantly even in one room.
CONTROLS AND OPERATION
NOTE: The humidifier should be placed at least FOUR inches away from any walls or curtains, and away from heat registers. Do not place on soft carpet. Unrestricted airflow into the unit will result in the best efficiency and performance.
ANALOG
HYGROMETER
GAUGE
HUMIDITY CONTROL
KNOB
2 SPEED FAN KNOB
1) This unit has two fan speeds controlled by the lower right hand knob.
2) The humidity level knob is located above the fan speed knob. Increase humidity by turning the upper knob from left to right.
3) The analog hygrometer in the upper left hand section displays the room humidity.
NOTE: NOTE: If excessive condensation forms on wall or windows, reduce fan to a lower speed setting or change location.
6
CARE AND MAINTENANCE
Cleaning your humidifier regularly helps eliminate odors and bacteria/ fungal growth. Ordinary household bleach is a good disinfectant and can be
used to wipe out the humidifier base after cleaning .We recommend cleaning your humidifier at least once every two weeks to maintain optimum environmental conditions for your home. We also recommend using
AIRCARE humidifier to eliminate bacterial growth. Add bacteriostat according to the
instructions on the bottle. Please call 1-800-547-3888 to order Bacteriostat Treatment, part number 1970.
CLEANING INSTRUCTIONS
1) Turn off unit completely and unplug from outlet.
2) Lift off chassis from base and set aside. Carry base to basin/sink for
3) Lift wick from base, allow water to drain from wick into base and then set aside.
REMOVING SCALE
4) Empty base into sink. Remove any remaining water from base with a sponge.
5) Fill base to “MAX FILL” line with water and then add 8oz. (1cup) of white
6) Clean all interior surfaces of base with a soft brush. Dampen soft cloth with
7) Rinse base thoroughly with fresh water and remove scale and cleaning
DISINFECTING UNIT
8) Fill the base ½ full with water and add 1 teaspoon of bleach. Let solution
9) Refill unit and reassemble per ASSEMBLY instructions.
SUMMER STORAGE
1) Clean unit as outlined above.
2) Discard used wick and any water in the reservoir. Allow to dry thoroughly
3) Do not store unit in an attic or other high-temperature area, as damage is
4) Install new filter at beginning of season.
®
or Essick Air® Bacteriostat Treatment each time you refill your
cleaning.
vinegar. Let solution stay 20 minutes, then empty.
white vinegar and wipe out base to remove scale.
solution.
stay for 20 minutes, then rinse with water until bleach smell is gone. Dry interior surfaces with clean cloth. Wipe down the outside of the unit with a soft cloth dampened with fresh water.
before storage. Do not store with water inside reservoir.
probable.
7
SALES RECEIPT REQUIRED AS PROOF OF PURCHASE FOR ALL WARRANTY CLAIMS.
This warranty is extended only to the original purchaser of this humidifier when the unit is installed and used under normal conditions against defects in workmanship and materials as follows:
Two (2) years from date of sale on the unit, and  Thirty (30) days on wicks and filters, which are considered disposable
The manufacturer will replace the defective part/product, at its discretion, with return freight paid by the manufacturer. It is agreed that such replacement is the exclusive remedy available from the manufacturer and that TO THE MAXIMUM EXTENT PERMITTED BY LAW, THE MANUFACTURER IS NOT RESPONSIBLE FOR DAMAGES OF ANY KIND, INCLUDING INCIDENTAL AND CONSEQUENTIAL DAMAGE OR LOSS OF PROFITS OR REVENUES.
Some states do not allow limitations on how long an implied warranty lasts, so the above limitations may not apply to you.
Exclusions from this warranty
We are not responsible for replacement of wicks and filters. We are not responsible for any incidental or consequential damage from any
malfunction, accident, misuse, alterations, unauthorized repairs, abuse, including failure to perform reasonable maintenance, normal wear and tear, nor where the connected voltage is more than 5% above the nameplate voltage.
Alterations include the substitution of name brand components including, but not limited to wicks and bacteria treatment.
We are not responsible for any damage from the use of water softeners or treatments, chemicals or descaling materials.
We are not responsible for the cost of service calls to diagnose the cause of trouble, or labor charge to repair and/or replace parts.
No employee, agent, dealer or other person is authorized to give any warranties or conditions on behalf of the manufacturer. The customer shall be responsible for all labor costs incurred.
This warranty will be null & void if purchaser attempts to repair or replace any parts which are mechanical or electrical.
Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to you.
How to obtain service under this warranty
Within the limitations of this warranty, purchaser with inoperative units should contact customer service at 800-547-3888 for instructions on how to obtain service within warranty as listed above.
This warranty gives the customer specific legal rights, and you may also have other rights which vary from province to province, or state to state.
Register your product at www.essickair.com or www.AIRCAREproducts.com.
HUMIDIFIER TWO YEAR LIMITED WARRANTY POLICY
components and should be replaced periodically.