Essick Air CP70 User Manual

Portable Evaporative Cooler
Model
CP70
Read And Save These Instructions
NOTICE: This Product May Temporarily Produce An Odd Odor When First Turned On. This Is NORMAL And Will Dissipate After A Few Hours.
If you have any problems with this product, please call 1-800-643-8341 BEFORE returning it to your retailer.
Evaporative Cooling
Evaporative cooling is an economical way to cool. Air is cooled while being drawn across wet evapora­tive media. The movement of this fresh cooled air over the skin is what makes it feel cool. It is important when using an evaporative cooler in an enclosed space to have adequate exhaust by opening windows, doors, etc. Without an outlet to exhaust the air, humidity will build up in the enclosed space and the unit will not cool adequately. It is preferable to have an opening behind the unit to bring in fresh air and another opening across the room to exhaust and help move the air.
Safety Rules
1. Unit must be in the Off Position and Unplugged from power receptacle when performing any mainte­nance.
3. To reduce the risk of electric shock, install only on a circuit protected with a Ground Fault Circuit Inter­rupter (GFCI).
4. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
WARNING: To reduce the risk of fi re or electric shock, do not use this fan with any “solid-state
fan speed control device.”
Champion Cooler
110489-5 5/09
5800 Murray St.
Little Rock, AR 72209
www.championcooler.com
Cooler Installation
Install Pedestal and Casters
Base
Pedestal
Caster Unpack the unit and remove the media frame to access the pedestal and 4 cast­ers. See the maintenance section for instructions on removing media frame. CAUTION: Do not damage hose connecting pump to media frame. Cut
Screw the cable ties holding pedestal to frame of unit and remove pedestal. Remove the casters from the underside of the pedestal. To install the pedestal, turn the unit on it’s side. Line up the bosses on the pedestal to the bosses on the base of the unit (see fi g. 1). Use the four provided screws to attach the pedestal to the base of unit. Press the stem casters into each corner hole of pedestal, installing the 2 locking casters on the front and the 2 non-locking on the back side.
Fig. 1
Operation
Fill With W ater
To fi ll this unit with water, open the water fi ll door and fi ll with a pitcher or water hose (see fi g. 2). Do Not Overfi ll. CAUTION:
Take care when moving unit fi lled with water, spillage may occur. Unlock casters when moving. Do not tip unit.
Water Level Indicator
On the front of the unit there is an access window to view the level of the water (see fi g. 2). When the unit is full of water, the
Water Level
Indicator
level indicator will be at the top of the window and as the level of the water is decreased in the unit, the indicator will lower.
Refer to the control panel in fi gure 3 for the following instructions.
Turning On Unit
Once the unit is plugged in, pressing the “Power” button will light up the backlight on the display and start the unit in Fan-High mode. The pump will not start until the “Pump” button is pressed. The display will remain backlit for 2 minutes after the last button on the control is pushed.
Pump / Cooler Operation
To operate this unit as an evaporative cooler, the unit must be fi lled with water and the pump powered on. Press the “Pump” button to turn on the pump. The water drop indicator on the display will fl ash while the pump is on. To operate the unit as a fan only, press “Pump” to turn off the pump.
Note: The pump will not run if the water level falls below a certain level. When the water level drops below this level, an audible alarm will sound and the “Low Water” indicator on the display will fl ash on and off. The audible alarm will stop after 60 seconds or when the “Pump” button is pushed. The indica­tor will remain fl ashing until the unit is fi lled with water. You will need to restart the pump by pressing “Pump” after the unit is refi lled with water.
Fan Operation
Pressing the “Speed” button on the control will cycle the fan speed from High to Mid to Low. The speed setting will be highlighted in the display.
Oscillate Mode
FAN PUMP
LOW
OSCILLATE
Pressing the “Oscillate” button will oscillate the vertical vanes back and forth, distributing the air side to side. The “Oscillate” indicator on the display will be displayed when on. Press the button again to turn off.
Timer
Oscillate
Timer Mode
This unit is equipped with a timer. You may set the time interval for the unit to stay on. Pressing the “Timer” button will set the time interval in 1/2 hour increments up to 8 hours. The display will fl ash while setting the time and will display constantly once it is set. The display will count down the time remaining in 1/2 hour increments. When the time interval is reached, the unit will turn off.
MID
HIGH
COOL VENT
Power
Fig. 3
Fig. 2
Water Fill Door
Speed
LOWWATER
TIMER
hr
Pump
2
Maintenance
WARNING: Before doing any maintenance be sure unit is unplugged.
Drain Unit
To drain the unit, remove the media frame and remove the rubber drain stopper from the bottom of the unit by pulling it out of the drain hole. The unit should be drained periodically to keep the water fresh. We recommend draining the unit once a week. Drain the water from the unit when it will not be used for an extended period.
Note: To remove the media frame, rst remove the two screws located at the top of the frame (see g. 4). Tilt the frame back while pressing on the bottom of the frame where it says “Push” until it
snaps out, then lift out. The water distribution hose can be removed from the media frame to allow complete separation of media frame from unit. Do not operate unit with media frame removed.
Clean/Replace Evaporative Media
The evaporative media should be cleaned twice a season or when needed. To clean the media, rinse with clean water. Light scrub­bing might be necessary. Be careful not to damage media. After 2 years, or when it becomes clogged, the media will need to be replaced. To remove the media, fi rst remove the keeper disks from the keeper stems (see fi g. 4). Remove the keeper stems from the media and remove the media.
When replacing the evaporative media, install it so that the steeper ute angle of the media is sloping down towards the media frame (see fi g. 4). Push the keeper stems through the media from the back of the media frame and press the keeper disks onto the stems to secure the media in place.
Keeper
Disk
45°
15°
Screw
Keeper
Stem
Fig. 4
Limited Warranty
This warranty is extended to the original purchaser of an evaporative cooler installed and used under nor­mal conditions. It does not cover damages incurred through accident, neglect, or abuse by the owner. We do not authorize any person or representative to assume for us any other or different liability in connection with this product.
Terms And Conditions Of The Warranty
For One Year from date of purchase, we will replace any original component provided by Champion Cooler which fails due to any defect in material or factory workmanship only.
Exclusions From The Warranty
We are not responsible for replacement of evaporative media. These are disposable components and should be replaced periodically. We are not responsible for any incidental or consequential damage result­ing from any malfunction.
We are not responsible for any damage received from the use of water softeners, chemicals, de-scale mate­rial or plastic wrap.
We are not responsible for the cost of service calls to diagnose the cause of trouble, or labor charge to repair and/or replace parts.
How To Obtain Service Under This Warranty
Contact the Dealer where you purchased the evaporative cooler. If for any reason you are not satisfi ed with the response from the dealer, contact the Customer Service Department: Champion Cooler, 5800 Murray Street, Little Rock, Arkansas 72209. 1-800-643-8341. info@championcooler.com
This limited warranty applies to the original purchaser only.
Register your product online at www.championcooler.com/eac/onlineregistration-eac.htm
3
Loading...
+ 5 hidden pages