INSTRUCTION SHEET
LENTON® LOCK Closure Pour Splices
Step 1:
Read all instructions and procedures. Ensure LENTON LOCK is sized properly with project plans.
Refer to product instruction sheet for coupler installation procedure details. Additional copies of instructions
and application information are available at www.erico.com
Mark
Step 2
Place coupler on each rebar end until the rebar touches the stop pin.
Mark the rebar to ensure proper coupler/rebar engagement.
Stop Pin
Mark
If stop pin is
flush with coupler body:
not
PULL PIN OUT
PUSH PIN IN AND THROUGH CENTER OF COUPLER
If stop pin is flush with coupler body:
(Do not push thru)
Step 3
To allow rebar to pass entirely through the coupler, remove stop pin
by pulling it out or by punching through toward ID of sleeve and discard.
Step 4
WARNING:
1.
2.
3.
4.
The customer is responsible for:
a. Conformance to all governing codes.
b. The integrity of structures to which the products are attached, including their capability of safely accepting the loads imposed, as evaluated by a qualified engineer.
c. Using appropriate industry standard hardware as noted above.
SAFETY INSTRUCTIONS:
All governing codes and regulations and those required by the job site must be observed.
Always use appropriate safety equipment such as eye protection, hard hat, and gloves as appropriate to the application.
Slide coupler onto free rebar.
ERICO products shall be installed and used only as indicated in ERICO product instruction sheets and training materials. Instruction sheets are available at
your ERICO customer service representative.
ERICO products must never be used for a purpose other than the purpose for which they were designed or in a manner that exceeds specified load ratings.
All instructions must be
Improper installation, misuse, misapplication or other failure to completely follow ERICO's instructions and warnings may cause product malfunction, property damage, serious bodily
injury and death.
completely
followed to ensure proper and safe installation and performance.
www.erico.com
and from
CADDY, CADWELD, CRITEC, ERICO, ERIFLEX, ERITECH, and LENTON are registered trademarks of ERICO International Corporation.
TECHNICAL SUPPORT:
www.erico.com
PDF113_C
1 of 2
© 2010,2011,2014 ERICO International
Corporation.
INSTRUCTION SHEET
Step 5
Step 6
Align rebar
Center coupler, ensuring rebar marks (completed in step 2) line up correctly.
Step 7
Torque bolts per product instruction sheet PDF116 for B-Series
couplers or PDF121 for S-Series couplers.
CADDY, CADWELD, CRITEC, ERICO, ERIFLEX, ERITECH, and LENTON are registered trademarks of ERICO International Corporation.
TECHNICAL SUPPORT:
www.erico.com
PDF113_C
2 of 2
© 2010,2011,2014 ERICO International