Enerpac XC-Series Instruction Manual

Page 1
XC-Series Cordless Hydraulic Pump
Instruction Manual
3
Page 2
General Safety
Never set the relief valve to a higher pressure than the maximum rated pressure of the pump. Higher settings may result in equipment damage or personal injury. Do not remove relief valve.
To avoid personal injury keep hands and feet away from cylinder and work piece during operation.
Do not handle pressurized hoses. Escaping oil under pressure can penetrate the skin, causing serious injury. If oil is injected under the skin, see a doctor immediately.
Do not pressurize disconnected couplers.
Safety First
Read all instructions, DANGER, WARNING and CAUTION paragraphs carefully. Follow all safety precautions to avoid personal injury or property damage during system operation. Save these instructions.
ENERPAC cannot be responsible for damage or injury resulting from unsafe product use, lack of maintenance or incorrect product and/or system operation. Contact ENERPAC when in doubt as to the safety precautions and operations
Conformance to National & International Standards.
We declare that this product has been tested and conforms to applicable standards and is approved to carry the CE, TUV C and US, and FCC certification marks. An EC Declaration of Conformity is enclosed separately.
Model / Serial Number
The model and serial number are found on the back side of unit, above the battery area.
Important
Danger icons are only used when your action or lack of action may cause serious injury or even death.
Failure to comply with DANGER, WARNING or CAUTION statements could cause equipment damage and personal injury.
General Safety 4 Electrical Safety 6 Installation 7 Use 8 Operation 9 Disconnecting 10 Oil Fill 11 Pressure Setting 12 Technical Specifications 13 Troubleshooting 14
Contents
Page 3
5
General Safety
Failure to comply with DANGER, WARNING or CAUTION statements could cause equipment damage and personal injury.
Immediately replace worn or damaged parts with genuine ENERPAC parts. Non genuine ENERPAC parts may break, causing personal injury and property damage. ENERPAC parts are designed to fit properly and withstand high loads.
Stay clear of loads supported by hydraulics. A cylinder, when used as a load lifting device, should never be used as a load holding device. After the load has been raised or lowered, it must always be blocked mechanically.
Only use hydraulic cylinders in a coupled system. Never use a cylinder with unconnected couplers. If the cylinder becomes extremely overloaded, components can fail catastrophically, causing severe personal injury.
Use only rigid pieces to hold loads. Carefully select steel or wood blocks that are capable of supporting the load. Never use a hydraulic cylinder as a shim or spacer in any lifting or pressing application.
Avoid situations where loads are not directly centered on the cylinder plunger. O-center loads produce considerable strain on cylinders and plungers. In addition, the load may slip or fall, causing potential danger.
The system operating pressure must not exceed the pressure rating of the lowest rated component in the system. Install pressure gauge in the system to monitor operating pressure. It is your window to see what is happening in the system.
Do not exceed equipment ratings. Never attempt to lift a load weighing more than the capacity of the cylinder. Overloading causes equipment failure and possible personal injury. The cylinders are designed for a max. pressure of 700 bar/10,000 psi/70 MPa. Do not connect a jack or cylinder to a pump with a higher pressure rating.
Wear proper personal protective gear when operating hydraulic equipment.
Be sure setup is stable before lifting load. Cylinders should be placed on a flat surface that can support the load. Where applicable, use a cylinder base plate for added stability. Do not weld or otherwise modify the cylinder to attach a base or other support.
Avoid damaging hydraulic hose. Avoid sharp bends and kinks when routing hydraulic hoses. Using a bent or kinked hose will cause severe back-pressure. Sharp bends and kinks will internally damage the hose, leading to premature hose failure.
Do not drop heavy objects on hose. A sharp impact may cause internal damage to hose wire strands. Applying pressure to a damaged hose may cause it to rupture.
Distribute the load evenly across the entire saddle surface. Always use a saddle to protect the plunger.
Do not lift hydraulic equipment by the hoses or swivel couplers. Use the carrying handle.
Keep hydraulic equipment away from flames and heat. Excessive heat will soften packings and seals, resulting in fluid leaks. Heat also weakens hose materials and packings. For optimum performance do not expose equipment to temperatures of 65 °C [150 °F] or higher. Protect all hydraulic equipment from weld spatter.
Hydraulic equipment must only be serviced by a qualified hydraulic technician. For repair service, contact the Authorized ENERPAC Service Center in your area. To protect your warranty, use only ENERPAC oil.
Do not exceed 25 percent duty cycle. Allow sucient time for the pump to cool between operations.
Indicates a potential danger that requires correct procedures or practices to avoid possible serious personal injury or death.
Is used to indicate correct operating or maintenance procedures and practices to prevent minor or moderate injury or damage to / destruction of equipment or other property.
WARNING CAUTION
Page 4
Electrical Safety
Failure to comply with DANGER, WARNING or CAUTION statements could cause equipment damage and personal injury.
Do not operate the pump in explosive atmospheres, such as in the presence of flammable liquids, gases, or dust. The pump creates sparks which may ignite the dust of fumes.
Do not expose the pump to rain or wet conditions. Water entering the pump will increase the risk of shock.
To avoid accidental starting, when carrying or moving the pump ensure the safety switch is in the locked position, and do not carry with hand or fingers on the trigger.
Do not operate pump if safety switch does not function. Seek repair assistance from an ENERPAC service center.
Remove battery pack from the pump before making any adjustments, performing maintenance or storing the pump.
Ensure the switch is in the locked position prior to inserting the battery pack.
Recharge only with the charger specified by the manufacturer. A charger that is suitable for one type of battery pack may create risk of fire when used with another battery pack.
Use the ENERPAC XC-Series pump only with MILWAUKEE ELECTRIC TOOL M28TM or V28TM Li-Ion battery packs. Use of any other battery packs may create risk of injury or fire.
When battery pack is not in use, keep it away from other metal objects like paperclips, coins, keys, nails, screws, or other small metal objects that can make a connection from one terminal to another. Shorting the battery terminals together may cause burns or fire.
Under abusive conditions, liquid may be ejected from the battery. Avoid contact. If contact accidentally occurs, flush with water. If liquid contacts eyes, additionally seek medical help. Liquid ejected from the battery can cause irritation or burns.
Read and understand the safety and operation instructions provided separately with the MILWAUKEE ELECTRIC TOOL battery and charger.
Additional Warnings for Battery Operated Electric Pumps.
WARNING
Page 5
7
Installation
1
4
5
6
60 - 70 Nm
44 - 53 ft lb
2
11/16"
& 15/16"
3/8” NPTF
60 Min = 100%
3
Gauge Recommended
Page 6
Use
1
2 3
Optional Strap Shown
Page 7
9
Operation
21 3
4 5
P
6
Page 8
Disconnecting
2
4
3
P
1
Page 9
11
Oil Fill
2 3
4
5
6
1/4"
1/4" 4.5 - 5.7 Nm
40 - 50 in lb
< Ø13mm
Pour slowly
P
1
Page 10
Pressure Setting
Factory Setting User Adjustable
2
1
7/32" x 6"
P
MAX
= 700 bar/10,000 psi/70 MPa
3
P
MAX
= 700 bar/10,000 psi/70 MPa
P
min
= 150 bar / 2,175 psi / 15 MPa
Flat head screwdriver
Page 11
13
Technical Specifications
Cylinder / Tool Valve
Charger Voltage 1 PH, 50/60Hz *
Usable Oil Capacity Weight
Model Number
Litres in³ kg lb
Single acting Manual 3 way, 2 position
115 V
1,0 60 9,9 21.9 XC-1201MB 2,0 120 10,8 23.8 XC-1202MB
230 V
1,0 60 9,9 21.9 XC-1201ME 2,0 120 10,8 23.8 XC-1202ME
- - -
1,0 60 9,9 21.9 XC-1201M** 2,0 120 10,8 23.8 XC-1202M**
Maximum Pressure
Flow Rate (Fig A)
Valve Function Motor
Battery *
No load 2,000 psi / 140 bar Max Load Voltage Type
700 bar 2,05 l/min. 0,50 l/min. 0,25 l/min
Advance / Release
0,37 KW
28 V Li-Ion
10,000 psi 125 in³/min. 30 in³/min. 15 in³/min. 0.50 HP
* For more information visit www.milwaukeetool.com ** Batteries and Charger not included.
0 140 280 420 560 700
0,33
0,66
1,00
1,33
1,66
2,00
2,33
0 2000 4000 6000 8000 10,000
20
40
60
80
100
120
140
Pressure (bar)
Flow (l/min)
Pressure (psi)
Flow in
3
/min
Fig A
Page 12
14
Troubleshooting
Problem Possible Cause Solution
Pump will not start.
Battery pack not installed. Install battery pack. Electrical contacts dirty or corroded. Clean contacts on the battery, pump and charger. Battery pack discharged. Charge battery. Battery pack shut o. Refer to battery/charger instruction sheet. Brushes worn. Contact ENERPAC service center. Trigger lock engaged. Undo trigger lock. Motor damaged. Contact ENERPAC service center.
Pump clicks when trigger is depressed, but does not start.
Electrical contacts dirty or corroded. Clean contacts on the battery, pump and charger. Battery pack discharged. Charge battery. Battery too cool or too warm. Get battery back to operating range (-20°C / 60°C) Battery pack damaged or not functioning. Replace battery pack. Pump jammed due to obstruction. Possible
internal damage to pump.
Contact ENERPAC service center.
Low fluid output.
Bypass valve malfunction. Contact ENERPAC service center. Oil intake screens clogged with debris. Contact ENERPAC service center. Internal damage to pump. Contact ENERPAC service center.
Cylinder will not advance or retract.
Oil level low. Add oil until reservoir is completely full. Oil intake screen clogged. Contact ENERPAC service center. Valve handle in wrong position. Shift valve to extend (pressure) position.
Pump slows down and stops. Battery pack discharged. Charge battery.
Cylinder advances and retracts erratically.
Air in the system. Extend and retract the cylinder until operation is smooth. External hydraulic leak. Tighten connections. Replace damaged components.
Internal leakage in valve. Contact ENERPAC service center. Internal damage to valve. Contact ENERPAC service center. Internal damage to pump. Contact ENERPAC service center.
Pump pulses and/or stops during prolonged or heavy operation.
Current draw too high.
Immediately release the trigger to prevent battery from shutting o. Allow time for battery pack to cool before restarting pump.
Note: If battery pack shuts o, place pack on charger to reset.
Pump does not build pressure. User adjustable relief valve set too low.
Adjust pressure (see page 10).
Noisy pump operation.
Pump element piston sticking. Contact ENERPAC service center. Motor or gear damaged. Contact ENERPAC service center.
Page 13
Page 14
xxxxx
220
e-mail: info@enerpac.com
Internet: www.enerpac.com
ENERPAC © 2013 - Subject to change without notice.
Australia and New Zealand
Actuant Australia Ltd. Block V Unit 3, Regents Park Estate 391 Park Road, Regents Park NSW 2143 (P.O. Box 261) Australia T +61 297 438 988 F +61 297 438 648 sales-au@enerpac.com
Brazil
Power Packer do Brasil Ltda. Rua Luiz Lawrie Reid 548 09930-760 - Diadema (SP) T +55 11 5687 2211 F +55 11 5686 5583 Toll Free: 0800 891 5770 vendasbrasil@enerpac.com
Canada
Actuant Canada Corporation 6615 Ordan Drive, Unit 14-15 Mississauga, Ontario L5T 1X2 T +1 905 564 5749 F +1 905 564 0305 Toll Free: T +1 800 268 4987 F +1 800 461 2456 customer.service@actuant.com
中国(太仓)
实用动力(中国)工业有限公司 中国江苏省 太仓经济技术开发区 南京东路 6 号
T +86 0512 5328 7500 F +86 0512 5335 9690
免费电话:
T +86 400 885 0369 sales-cn@enerpac.com
France, Switzerland, North Africa and French speaking African countries
ENERPAC, Une division d’ACTUANT France S.A.S. ZA de Courtaboeuf 32, avenue de la Baltique 91140 VILLEBON /YVETTE France T +33 1 60 13 68 68 F +33 1 69 20 37 50 sales-fr@enerpac.com
Germany and Austria
ENERPAC GmbH P.O. Box 300113 D-40401 Düsseldorf Willstätterstrasse 13 D-40549 Düsseldorf, Germany T +49 211 471 490 F +49 211 471 49 28 sales-de@enerpac.com
India
ENERPAC Hydraulics Pvt. Ltd. No. 1A, Peenya Industrial Area IInd Phase, Bangalore, 560 058, India T +91 80 40 792 777 F +91 80 40 792 792 sales-in@enerpac.com
Italy
ENERPAC S.p.A. Via Canova 4 20094 Corsico (Milano) T +39 02 4861 111 F +39 02 4860 1288 sales-it@enerpac.com
日本
アプライドパワージャパン株式会社 ( エナパック )
331-0821 埼玉県さいたま市北区別所町 85-7
Tel 048 662 4911 Fax 048 662 4955 enerpac@apj.ne.jp
Middle East, Egypt and Libya ENERPAC Middle East FZE
Oce 423, LOB 15 P.O. Box 18004, Jebel Ali, Dubai United Arab Emirates T +971 (0)4 8872686 F +971 (0)4 8872687 sales-ua@enerpac.com
Russia
Rep. oce ENERPAC Russian Federation Admirala Makarova Street 8 125212 Moscow, Russia T +7 495 98090 91 F +7 495 98090 92 sales-ru@enerpac.com
Southeast Asia, Hong Kong andTaiwan
Actuant Asia Pte Ltd. 83 Joo Koon Circle, Singapore 629109
전화 +65 68 63 0611 팩스 +65 64 84 5669 무료전화: 전화 +1800 363 7722
sales-sg@enerpac.com
대한민국
Actuant Korea Ltd.
시화공단 3Ba 717 정왕동 경기도 시흥시 대한민국 429-450 전화 +82 31 434 4506 팩스 +82 31 434 4507
sales-kr@enerpac.com
Spain and Portugal
ENERPAC SPAIN, S.L. Avda. Los Frailes, 40 – Nave C & D Pol. Ind. Los Frailes 28814 Daganzo de Arriba (Madrid) Spain T +34 91 884 86 06 F +34 91 884 86 11 sales-es@enerpac.com
Sweden, Denmark, Norway, Finland and Iceland
ENERPAC Scandinavia AB Fabriksgatan 7 412 50 Gothenburg, Sweden T +46 (0) 31 799 0281 F +46 (0) 31 799 0010 scandinavianinquiries@enerpac.com
The Netherlands, Belgium, Luxembourg, Central and Eastern Europe, Baltic States, Greece, Turkey and CIS countries
ENERPAC B.V. Galvanistraat 115 6716 AE Ede P.O. Box 8097 6710 AB Ede The Netherlands T +31 318 535 911 F +31 318 535 848 sales-nl@enerpac.com
South Africa and other English speaking African countries
ENERPAC AFRICA ( PTY ) Ltd. Cambridge Oce Park, Block E 5 Bauhinia Avenue Highveld Techno Park, Centurion Republic of South Africa T 0027 (0) 12 940 0656 sales-za@enerpac.com
United Kingdom and Ireland
ENERPAC Ltd., Bentley Road South Darlaston, West Midlands WS10 8LQ England T +44 (0)121 50 50 787 F +44 (0)121 50 50 799 sales-uk@enerpac.com
USA, Latin America and Caribbean
ENERPAC World Headquarters P.O. Box 3241 Milwaukee, WI 53201-3241 USA N86 W12500 Westbrook Crossing Menomonee Falls, WI 53051 T +1 262 293 1600 F +1 262 293 7036 User inquiries: +1 800 433 2766 Distributor inquiries/orders: +1 800 558 0530 +1 800 628 0490 Technical inquiries: techservices@enerpac.com sales-us@enerpac.com
L4004_b
Rev. B/04/2013
Loading...