Enerco MH175KT, HS125KT, HS50KT, MH125KT, MH75KT User Manual

...
OPERATING INSTRUCTIONS AND OWNER’S MANUAL
MR. HEATER
MODEL
MH50KT, MH75KT, MH125KT, MH175KT
READ INSTRUCTIONS CAREFULLY: Read and follow all instructions. Place instructions in a safe place for future reference. Do not allow anyone who has not read these instructions to assemble, light, adjust or operate the heater.
HEATSTAR
MODEL
HS50KT, HS75KT, HS125KT, HS175KT
KEROSENE FORCED-AIR HEATER
WARNING:
— Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any
other appliance.
— Service must be performed by a qualified service agency.
This is an unvented portable heater. It uses air (oxygen) from the area in which it is used. Adequate combustion and ventilation air must be provided. Refer to page 3.
If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
UL-733, &CSA/CAN3-B140.9.3
04/04 Revision L1 #70276ENERCO GROUP, INC., 4560 W. 160TH ST., CLEVELAND, OHIO 44135 • 216-881-5500
WARNING:
YOUR SAFETY IS IMPORTANT TO YOU AND TO OTHERS, SO PLEASE READ THESE INSTRUCTIONS BEFORE YOU
OPERATE THIS HEATER.
GENERAL HAZARD WARNING:
FAILURE TO COMPLY WITH THE PRECAUTIONS AND INSTRUCTIONS PROVIDED WITH THIS HEATER, CAN
RESULT IN DEATH, SERIOUS BODILY INJURY AND PROPERTY LOSS OR DAMAGE FROM HAZARDS OF FIRE, EXPLOSION, BURN, ASPHYXIATION, CARBON MONOX­IDE POISONING, AND/OR ELECTRICAL SHOCK.
ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW
THE INSTRUCTIONS SHOULD USE OR SERVICE THIS HEATER.
IF YOU NEED ASSISTANCE OR HEATER INFORMATION SUCH AS AN INSTRUCTIONS MANUAL, LABELS, ETC.
CONTACT THE MANUFACTURER.
WARNING:
NOT FOR HOME OR RECREATIONAL VEHICLE USE
WARNING:
FIRE, BURN, INHALATION, AND EXPLOSION HAZARD. KEEP SOLID COMBUSTIBLES, SUCH AS BUILDING
MATERIALS, PAPER OR CARDBOARD, A SAFE DIS­TANCE AWAY FROM THE HEATER AS RECOMMENDED BY THE INSTRUCTIONS NEVER USE THE HEATER IN SPACES WHICH DO OR MAY CONTAIN VOLATILE OR AIRBORNE COMBUSTIBLES, OR PRODUCTS SUCH AS GASOLINE, SOLVENTS, PAINT THINNER, DUST PAR­TICLES OR UNKNOWN CHEMICALS.
WARNING:
The State of California requires the following warning:
COMBUSTION BY-PRODUCTS PRODUCED WHEN USING THIS PRODUCT CONTAIN CARBON MONOXIDE, A CHEMICAL KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER AND BIRTH DEFECTS (OR OTHER REPRODUCTIVE HARM).
WARNING:
• DO NOT USE GASOLINE, NAPHTHA OR VOLATILE FUELS.
• STOP HEATER BEFORE ADDING FUELS.
• ALWAYS FILL OUTDOORS AWAY FROM OPEN FLAME
• DO NOT USE EXTERNAL FUEL SOURCE.
• DO NOT OPERATE HEATER WHERE FLAMMABLE LIQUIDS OR VAPORS MAY BE PRESENT.
• DO NOT START HEATER WHEN CHAMBER IS HOT
• DO NOT START HEATER WHEN EXCESS FUEL HAS ACCUMULATED IN THE CHAMBER.
• DO NOT PLACE COOKING UTENSILS ON TOP OF THE HEATER.
• PLUG ELECTRICAL CORD INTO A PROPERLY GROUNDED THREE-PRONG RECEPTACLE.
50K & 75KT WARNING:
Not suitable for use on wood floors or other combustible materials. When used the heater should rest on a suitable insulating material at least 1 inch thick and extending 3 feet or more beyond the heater in all directions.
CONTENTS
WARNINGS ................................................................................. 2
HEATER SPECIFICATIONS ............................................................ 3
OPERATING PRECAUTIONS ......................................................... 3
SAFETY PRECAUTIONS ................................................................ 3
OPERATING INSTRUCTIONS ........................................................ 4
MAINTENANCE, STORAGE AND SERVICE ................................... 5
WIRING DIAGRAM...................................................................... 6
PARTS LIST .................................................................................. 6
EXPLODED VIEW......................................................................... 7
WARRANTY ................................................................................ 8
INSTRUCTIONS FOR ORDERING PARTS ....................................... 8
Enerco Group, Inc. | Kerosene Forced Air Heater Operating Instructions and Owner’s Manual
2
SPECIFICATIONS
Type of Fuel: For use with Kerosene or #1 Fuel Oil ONLY on ALL models.
Model ...................................... 50K ............................................. 75KT .......................................125KT ....................................... 175KT
Burn Rate:................................ 50,000 Btu/hr (15 kW) ...............75,000 Btu/hr (22 kW) ......... 125,000 Btu/hr (37 kW) ........... 175,000 Btu/hr (51 kW)
Fuel Rate:................................. 0.37 gal/hr (1.4 L/hr) ................. 0.55 gal/hr (2.1 L/hr) .............0.96 gal./hr (3.5 L/hr) ............. 1.3 gal/hr (5.0 L/hr)
Electrical Input: ........................ 115V, 60Hz, 3.5a .........................115V, 60Hz, 4a ....................... 115V, 60Hz, 5.5a ...................... 115V, 60Hz, 5.5a
Line Protection:........................ 10 amps ......................................10 amps ................................. 20 amps ................................... 20 amps
Min. Operating Voltage: .......... 110V ............................................110V ....................................... 110V ......................................... 110V
Pressure Setting: ...................... 3.5 psig (24 kPa) ........................4.2 psig (29 kPa) .................... 5.0 psig (34 kPa) ...................... 5.8 psig (40 kPa)
Max. Outlet Temperature:........ 1300oF (704oC) ............................1300oF (704oC) ....................... 1300oF (704oC) ......................... 1300oF (704oC)
Fuel Tank Capacity: .................. 4 gallons (15.1 L)........................ 6 gallons (22.7 L) ................... 14 gallons (53 L) ...................... 14 gallons (53 L)
Ignition: ................................... Direct Spark, Continuous............ Direct Spark, Continuous ....... Direct Spark, Continuous ......... Direct Spark, Continuous
Spark Generator: ..................... Igniter 13 kV, 10ma .................... Igniter 13 kV, 10ma ................ Igniter 13 kV, 10ma .................. Igniter 13 kV, 10ma
Primary Safety Control:............ Solid State Control...................... Solid State Control ................. Solid State Control ................... Solid State Control
Certification:
OPERATING PRECAUTIONS
This is a kerosene, direct-fired, forced air heater. It's intended use is primarily temporary heating of buildings under construction, alteration or repair.
Direct-Fired means that all of the combustion products enter the heated space. Even though this heater operates very close to 100 percent combustion efficiency, it still produces small amounts of carbon monoxide. Carbon monoxide (called CO) is toxic. We can tolerate small amounts but not a lot. CO can build up in a heated space and failure to provide adequate ventilation could result in death. The symptoms of inadequate ventilation are:
headache
dizziness
burning eyes and nose
nausea
dry mouth or sore throat
So, be sure to follow advice about ventilation in these operating instructions.
Forced Air means that a blower or fan pushes the air through the heater. Proper combustion depends upon this air flow; therefore, the heater must not be revised, modified or operated with parts removed or missing. Likewise, safety systems must not be circumvented or modified in order to operate the heater.
When the heater is to be operated in the presence of other people the user is responsible for properly acquainting those present with the safety precautions and instructions, and of the hazards involved.
SAFETY PRECAUTIONS
1. Check the heater thoroughly for damage. DO NOT operate a damaged heater.
2. DO NOT modify the heater or operate a heater which has been modified from its original condition.
3. Use only Kerosene. Never use gasoline, naphtha, paint thinner, alcohol or other fuels of any kind.
4. For indoor use only. Not for use where exposed to weather.
5. Use in well ventilated areas, provide at least 2 sq. ft. (0.19 sq. m.) of opening near the floor and 2 sq. ft. (0.19 sq. m.)
near the ceiling directly to outdoors. Increase air openings as marked for each additional heater.
6. Always keep combustibles, like paper and wood at least 8 ft. (2.4 m) from the heater outlet and 3 ft. (1.0 m) from the top, sides and inlet. Locate 10 ft. (3.0 m) from canvas or plastic coverings and secure them to prevent flapping movement.
7. Caution: Due to the high surface and exhaust temperatures, adults and children must observe clearances to avoid burns or clothing ignition. Do Not Touch. Keep Children, Clothing, and Combustibles away.
8. Install the heater such that it is not directly exposed to water spray, rain and / or water.
9. Never use in areas normally for habitation and /or where children may be present.
10. Operate only on a stable, level surface. (MH50K & MH75KT – See wood floor warning).
11. Do not use with duct work. Do not restrict inlet or exit.
12. Use only with electrical power specified. The electrical connection and grounding must comply with National Electrical Code – ANSI/NFPA 70 (USA) and CSA C22.1 Canadian Electrical Code, Part 1 (Canada).
13. Use only a properly grounded 3-prong receptacle or extension cord.
14. Do not move, handle, or service while hot or burning.
15. Use only in accordance with local, state (provincial) or National requirements, ordinances and codes.
OPERATING INSTRUCTIONS
UNPACKING
1. Remove all protective material which may have been applied to the heater for shipment.
2. Remove heater from carton.
3. Check the heater for possible shipping damage. If any damage is found immediately notify the dealer from whom you purchased the heater.
ASSEMBLY (For 125,000 and 175,000 BTU/hr models only)
Wheel and handles are found in the shipping carton along with mounting hardware. The wheels, axle and mounting hardware are in a package. Tools required are a 5/16" nutdriver, 3/8" open or adjustable wrench and standard pliers.
Enerco Group, Inc. | Kerosene Forced Air Heater Operating Instructions and Owner’s Manual
3
Loading...
+ 5 hidden pages