OPERATING INSTRUCTIONS AND OWNER’S MANUAL
MR. HEATER
MODEL
MH35LP
READ INSTRUCTIONS CAREFULLY: Read and
follow all instructions. Place instructions in a
safe place for future reference. Do not allow
anyone who has not read these instructions to
assemble, light, adjust or operate the heater.
GAS-FIRED INFRA-RED
PORTABLE CONSTRUCTION HEATER
DO NOT LEAVE HEATER UNATTENDED OR IN OPERATION WHILE SLEEPING
HEATSTAR
MODEL
HS35LP
CYLINDER NOT INCLUDED
GENERAL HAZARD WARNING:
FAILURE TO COMPLY WITH THE PRECAUTIONS AND INSTRUCTIONS PROVIDED WITH THIS HEATER
CAN RESULT IN DEATH, SERIOUS BODILY INJURY AND PROPERTY LOSS OR DAMAGE FROM
HAZARDS OF FIRE, EXPLOSION, BURN, ASPHYXIATION, CARBON MONOXIDE POISONING, AND/OR
ELECTRICAL SHOCK.
ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW THE INSTRUCTIONS SHOULD USE OR
SERVICE THIS HEATER.
IF YOU NEED ASSISTANCE OR HEATER INFORMATION SUCH AS INSTRUCTION MANUALS, LABELS,
ETC., CONTACT THE MANUFACTURER.
WARNING:
FIRE, BURN, INHALATION AND EXPLOSION HAZARD. KEEP SOLID COMBUSTIBLES SUCH AS
BUILDING MATERIALS, PAPER OR CARDBOARD A SAFE DISTANCE AWAY FROM THE HEATER AS
RECOMMENDED BY THE INSTRUCTIONS. NEVER USE THE HEATER IN SPACES WHICH DO OR MAY
CONTAIN VOLATILE OR AIRBORNE COMPUSTIBLES OR PRODUCTS SUCH AS GASOLINE, SOLVENTS,
PAINT THINNER, DUST PARTICLES OR UNKNOWN CHEMICALS.
WARNING: NOT FOR HOME OR RECREATIONAL VEHICLE USE
04/04 Revision L1 #18675ENERCO GROUP, INC., 4560 W. 160TH ST., CLEVELAND, OHIO 44135 • 216-881-5500
SPECIFICATIONS
MODEL NO. ...............35LP
35LP
GAS TYPE ................ LP-Gas
MAX. INLET
PRESSURE. ......... 27.5” W.C.
MIN. INLET
PRESSURE.......... 27.5” W.C.
MANIFOLD
PRESSURE..........25.5” W.C.
Do not exceed the gas supply pressures shown on rating plate
for Model 35LP. The maximum inlet gas supply pressure and the
minimum inlet gas supply pressure (for purposes of input
adjustment) for LP-Gas are shown as follows:
WARNING
DO NOT EXCEED 27.5” W.C. (1 psi) INLET
PRESSURE TO HEATER.
VENTILATION
WARNING
THIS APPLIANCE IS UNVENTED AND MUST BE
USED ONLY IN A WELL VENTILATED AREA.
The flow of combustion and ventilation air must not be
obstructed. DO NOT use in a tightly enclosed area. Any
combustion process requires and consumes oxygen, and may
produce carbon monoxide. This heater must be operated with
adequate ventilation. Two openings directly to the outdoors must
be provided, one low and one high, preferably on opposite sides
of the area to be heated. Each of these openings must provide at
least three square inches of combustion air-intake area and
exhaust outlet area for every 1000 BTUs per hour of heater input
rate in order to complete the combustion/ventilation process.
Provide additional ventilation for any additional fuel-burning
appliances and/or additional occupants.
CLEARANCE (Minimum clearances to combustible materials)
MODEL NO. BTU/HR RATING NORMAL OPERATING CLEARANCES TO
TYPE GAS POSTION COMBUSTIBLES
NATURAL LP & NG TOP SIDES BACK FRONT
35LP 35,000* VERTICAL 40” 40” 0” 54”
*Tank size and tank temperature can directly affect BTU output
CONTENTS
FOR YOUR SAFETY
Installation Instructions.................................................... 3
Location .......................................................................... 3
Piping .............................................................................. 3
Operating Instructions ..................................................... 4
Lighting and Shut Down .................................................. 4
Maintenance Instructions ................................................ 5
Replacement Parts List ..................................................... 6
Service and Parts Ordering Information ........................... 8
Do not use this heater in a space where
gasoline or other liquids having flammable
vapors are stored or used.
The heater is designed and approved for use as a construction
heater under ANSI Z83.7 / CGA 2.14 - 2000
We cannot anticipate every use which may be made of our
heaters. CHECK WITH YOUR LOCAL FIRE SAFETY AUTHORITY IF
YOU HAVE QUESTIONS ABOUT APPLICATIONS.
Other standards govern the use of fuel gases and heat producing
products in specific applications. Your local authority can advise
you about these.
This appliance is intended to be used primarily for the heating of
buildings under construction, alteration or repair.
THE STATE OF CALIFORNIA REQUIRES THE FOLLOWING WARNING:
WARNING
Combustion by-products produced when using this product contain
carbon monoxide, a chemical known to the State of California to
cause cancer and birth defects (or other reproductive harm).
Operating Instructions and Owner’s ManualEnerco Group, Inc. | Gas-Fired Infra-Red Portable Construction Heater
2
GENERAL INFORMATION
A. Your Enerco Technical Products portable gas-fired infra-red
heater comes fully assembled and is tested at the factory for
proper gas and input as stated on the nameplate.
B. Each heater is equipped with a 100% safety shutoff, push
button valve which will automatically stop the flow of gas in
the event the heater fails to operate for any reason. A tip
over switch and an excess flow check are also standard on
the model 35LP.
C. Before proceeding with this installation, be sure to inspect
for damages. The freight company must be notified of any
damages and request that an inspection be made. Enerco
Technical Products will send replacements for damaged
parts only after receiving a signed inspection report to
prove the liability of the freight company.
FOR SAFE OPERATION
A. READ THESE INSTRUCTIONS CAREFULLY. Read and
adhere to these instructions. DO NOT allow anyone
who has not read these instructions to assemble, light,
adjust or operate this heater.
B. LP-Gas IS HIGHLY FLAMMABLE. In the event of a leak, LP-
Gas will accumulate and the possibility of a fire is present.
LP-Gas is scented and its strong odor is readily detectable.
Never strike a match, bring any flame or create an electric
spark in an enclosure when you smell LP-Gas. Ventilate the
area thoroughly, move the heater outside, and correct the
source of the leak before attempting to light any appliance.
C. Always operate the heater with the LP-Gas cylinder in an
upright position on a level non-combustible surface. NEVER
PLACE THE CYLINDER ON ITS SIDE WHEN OPERATING
THE HEATER.
D. DO NOT attempt to operate the heater with any gas
other than that indicated on the heater nameplate.
The minimum ambient temperature rating for this heater is 20
degrees F.
This heater incorporates a “Tip Over” switch which automatically
shuts off the burner in the event of tipping. Ensure that this
switch is in the vertical position and is secured with the screws
provided (see Fig. 4). DO NOT operate this heater with the
LP-gas supply cylinder in any other than the upright
position.
LOCATION
Although this heater incorporates a “tip over” switch, the heater
and LP-Gas supply cylinder must be located on a hard, flat, level
surface to minimize the risk of accidental tipping. The LP Gas
supply cylinder should be adequately restrained to prevent
accidental tipping. DO NOT OPERATE this heater with the
supply cylinder in any other than the upright position.
This appliance must be installed only in locations where the
potential for physical damage to the appliance (i.e., due to
physical contact) is reduced to a minimum.
The installer must inform the owner/operator of this appliance
that precautions must be taken to protect the appliance from
physical damage.
This appliance produces radiant heat. Therefore, it must be
located at least six feet away from any LP-Gas container and
must not be directed toward any LP-Gas container within 20 feet.
The heater must be installed in a location such that it will not be
exposed directly to water spray, rain, and/or dripping water.
Use of this heater in a draft/windy area may decrease its
efficiency. If possible, operate the unit in a draft free area or
turn the face of the heater away from the draft.
PIPING:
For Model 35LP
(for use with LP-Gas)
INSTALLATION INSTRUCTIONS
GENERAL
For the U.S. and/or Canada, the installation of this appliance
must comply with local and/or Provincial codes or, in the
absence of these codes,
• With the (U.S.) National Fuel Gas Code, ANSI Z223.1 –
Latest Edition, AND with the (U.S.) Standard for the Storage
and Handling of Liquified Petroleum Gases, ANSI/NFPA 58,
OR
• With the current (Canadian) CAN/CGA B149.1 AND B149.2
INSTALLATION CODES.
This heater (including hose and regulator assembly) must be
inspected before each use and at least annually by a qualified
service person. If the hose for Model 35LP shows evidence of
excessive abrasion or wear, or if the hose is cut, it must be
replaced prior to the heater being put into operation. The
replacement hose assembly shall be that specified by the
manufacturer. See the parts list.
This model may be connected to a self-contained LP-Gas supply
system using the hose and regulator assembly supplied with the
appliance, OR, it may be connected to a permanently installed
LP-Gas supply system.
If connected to a self-contained LP-Gas supply system, the hose
assembly must be inspected prior to each use of the heater. If it
is evident that there is excessive abrasion or wear, or the hose is
cut, it must be replaced prior to the heater being put into
operation.
If connected to a self-contained LP-Gas supply system, the
cylinder must have no less than a minimum capacity of 20
pounds and no more than a maximum capacity of 100 pounds of
LP-Gas. DO NOT connect this appliance to a cylinder having less
than a nominal 20 pound capacity of LP-Gas. DO NOT connect
this appliance to more than one (1) 100 pound cylinder.
WARNING
NEVER USE A FORK LIFT TRUCK TYPE
CYLINDER.
Operating Instructions and Owner’s ManualEnerco Group, Inc. | Gas-Fired Infra-Red Portable Construction Heater
3