and follow all instructions. Place instructions in
a safe place for future reference. Do not allow
anyone who has not read these instructions to
assemble, light, adjust or operate the heater.
HEATSTAR
BY ENERCO
MODEL
HS155IR
DIRECT FIRED INFRARED
PORTABLE HEATER
WARNING :
— Do not store or use gasoline or other ammable vapors and liquids in the vicinity of this or any
other appliance.
— Service must be performed by a qualied service agency.
This is an unvented portable heater. It uses air (oxygen) from the area in which it is used. Adequate
combustion and ventilation air must be provided. Refer to page 5.
If the information in this manual is not followed exactly, a re or explosion
may result causing property damage, personal injury or loss of life.
SO PLEASE READ THESE INSTRUCTIONS BEFORE YOU
OPERATE THIS HEATER.
GENERAL HAZARD WARNING:
FAILURE TO COMPLY WITH THE PRECAUTIONS AND
INSTRUCTIONS PROVIDED WITH THIS HEATER, CAN
RESULT IN DEATH, SERIOUS BODILY INJURY AND
PROPERTY LOSS OR DAMAGE FROM HAZARDS OF FIRE,
EXPLOSION, BURN, ASPHYXIATION, CARBON MONOXIDE POISONING, AND/OR ELECTRICAL SHOCK.
ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW
THE INSTRUCTIONS SHOULD USE OR SERVICE THIS
HEATER.
IF YOU NEED ASSISTANCE OR HEATER INFORMATION
SUCH AS AN INSTRUCTIONS MANUAL, LABELS, ETC.
CONTACT THE MANUFACTURER.
WARNING:
NOT FOR HOME OR RECREATIONAL VEHICLE USE
WARNING:
FIRE, BURN, INHALATION, AND EXPLOSION HAZARD.
KEEP SOLID COMBUSTIBLES, SUCH AS BUILDING MATERIALS, PAPER OR CARDBOARD, A SAFE DISTANCE
AWAY FROM THE HEATER AS RECOMMENDED BY THE
INSTRUCTIONS NEVER USE THE HEATER IN SPACES
WHICH DO OR MAY CONTAIN VOLATILE OR AIRBORNE
COMBUSTIBLES, OR PRODUCTS SUCH AS GASOLINE,
SOLVENTS, PAINT THINNER, DUST PARTICLES OR UNKNOWN CHEMICALS.
WARNING:
The State of California requires the following warning:
COMBUSTION BY-PRODUCTS PRODUCED WHEN US-
ING THIS PRODUCT CONTAIN CARBON MONOXIDE,
A CHEMICAL KNOWN TO THE STATE OF CALIFORNIA
TO CAUSE CANCER AND BIRTH DEFECTS (OR OTHER
REPRODUCTIVE HARM).
WARNING:
READ THE INSTRUCTIONS GIVEN IN THIS
MANUAL BEFORE USING THE APPLIANCE.
• DO NOT USE GASOLINE, NAPHTHA OR VOLATILE
FUELS.
• THE ELECTRICAL SYSTEM TO WHICH THE APPLIANCE
IS CONNECTED MUST COMPLY WITH ALL SAFETY
REGULATIONS IN FORCE. A RESIDUAL CURRENT
CIRCUIT BREAKER MUST BE PROVIDED ON THE MAIN
DISTRIBUTION BOARD.
• UNPLUG THE HEATER BEFORE ATTEMPTING ANY
SERVICE OR MAINTENANCE.
• ALWAYS CHECK THE POWER SUPPLY CABLE BEFORE
USE. IT MUST NOT BE BENT, CRUSHED, OR ANYWAY
DAMAGED.
PARTS LIST ................................................................................... 8
• DO NOT TOUCH THE EXHAUST GAS OUTLET. DANGER
OF BURNS!
ENERCO GROUP, INC. |Direct Fired Portable HeaterOperating Instructions and Owner’s Manual
2
IMPORTANT
Before using the heater, read and understand all
instructions and follow them carefully. The manufacturer
is not responsible for damages to goods or persons due
to improper use of units.
GENERAL RECOMMENDATIONS
The heater described in this manual is a portable oil-fueled
infrared heat generator running on heating oil.
Its easy handling and large fuel tank allow it to be used locally and
temporarily with complete stand-alone operation. The area to be
heated is therefore hit by an even and uniform flow of heat, as can be
seen by the shape of the irradiation cone (18), without air movement.
The unit is a direct combustion hot generator that works by
sending both hot air and combustion products in the room you wish
heat: all the necessary precautions must therefore be taken to
to
guarantee a sufficient exchange of air.
Always follow local ordinances and codes when using this heater:
• Read and follow this owner’s manual before using the heater;
• THE INSTALLATION OF THE UNIT SHALL BE IN
ACCORDANCE WITH THE REGULATIONS OF THE
AUTHORITIES HAVING JURISDICTION. Also, as a
recommended installation practice reference should be made to
the current issue of CSA B139, Installation Code for Oil Burning
Equipment in Canada and NFPA 31 Standard for the Installation
of Oil-Burning Equipment In the USA;
• Use only in places free of flammable vapours or high dust
content;
• Never use heater in immediate proximity o
(the
minimum distance must be 10 feet);
• Make sure fire fighting equipment is readily available;
• Make sure sufficient fresh outside air is provided according to
the heater requirements. Direct combustion heaters should only
be used in well vented areas in order to avoid carbon monoxide
poisoning;
• A rough estimate of opening required for each gallon (US) of
capacity is three square foot at heater level, for direct-fired
heaters;
• The heater is installed and connected to an electrical
switchboard;
• Ensure that the machine resting surface or ground is not made
of flammable material;
• Minimum clearances from combustible material must be:
30” from side and rear (air inlet) of heater
80” from ceiling
40” on air outlet of heater.
• Never block air inlet (rear) or air outlet (front);
• In case of very l
oi
l;
• Connect the power cord to the mains and wait 15 min at least
be fore starting heater, to allow pre-heated filter warming
heating oil inside the filter;
• Make sure heater is always under surveillance and keep
children and animals away from it;
• Before starting the heater always check free rotation of
ventilator;
• Heater is not ductable.
• Unplug heater when not in use.
ow temperatures add kerosene to the heating
f flammable materials
TECHNICAL SPECIFICATIONS
Max heating output
Fuel consumption
Power supply
Power consumption
Nozzle
Pump pressure
Adjustment of combustion air flap
Tank capacity
Noise level at 1 m
Phase
Voltage
Frequency
FIRE 155
[BTU/h] 154.237
[gal/h] 1,11
1
[V] 120
[Hz] 60
[W] 440
[USgal/h]Delavan 0,85 - 80° W
PSI 174
[N°] 2
[USgal] 17.17
[dBA] 72
Dimensions, L x W x H
Weight
[in] 55.5 x 28.03 x 41.5
[lb] 161
Operating Instructions and Owner’s ManualENERCO GROUP, INC. |Direct Fired Portable Heater
3
SAFETY DEVICES
The unit is fitted with an electronic flame control box. In case of
malfunction this box will cut in and stop the heater, at the same time
the pilot lamp in the control box reset button (13) will light up.
WARNING
The reset push-button emits a different colour light,
depending on the state of the machine:
• green, when the machine is running regularly;
• red, when the machine is in safety lock-out mode: to
restart it , the reset button (13) must be pressed.
Heaters are also equipped with an overheat thermostat safety cut
out which will stop the heater in case of overheating. This thermostat
will reset automatically but you will have to depress button (13) on
control box before being able to restart the heater.
Before any attempt of starting the heater is made, check that
your electrical supply conforms to the data on the model plate.
Control Board
14
32
O N
0
O N
5
OPERATION
Before any attempt of starting the heater is made, check that your
electrical supply conforms to the data on the model plate.
WARNING
Mains must be fitted with a thermo-magnetic
differential switch.
Unit plug must be linked to a socket with a mains
switch.
The hot generator must be placed on a flat, stable and level
surface to avoid machine tipping and/or gas oil leakage from the tank
fuel cap.
The flow of heat can be directed upward with an approximately 10°
angle: loosen the two locking knobs (A) and tilt the combustion unit
by pressing on the handle until the desired angle is reached, then
lock the knobs (A) by tightening.
1 RESET BUTTON WITH CONTROL LAMP
2 CONTROL LAMP
3 MAIN SWITCH
4 ROOM TH ERM OSTAT PLUG
5 POWER CORD
Gap of Electrodes
WARNING
Before start-up, always ensure the guard (B) has been
completely pulled out, so as to guarantee maximum
protection of the machine resting surface.
ENERCO GROUP, INC. |Direct Fired Portable HeaterOperating Instructions and Owner’s Manual
Clearances
The following minimum safety clearances from materials or objects
in the surroundings of the heater must be ensured:
Sides 30 in. Air Inlet 30 in.
Top 80 in. Air outlet
40 in.
•
the room where the heater is operated.
• The air inlet and outlet must never be blocked for any
reason.
•
•
4
Loading...
+ 8 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.