Endress+Hauser TA562 Specifications

Page 1
Technical Information
Industrial thermowell Omnigrad TA562
Heavy duty - General purpose From hexagonal bar stock - Threaded process connections Also DuPont SR1T/SR2T
TA562 is designed for use with resistance and thermocouple thermometers mainly in heavy duty applications.

Benefits at a glance

• TA562 is an industry standard thermowell, manufactured from hexagonal bar stock.
• The process connections are threaded: ½"NPT, ¾"NPT, G½" or M20x1.5
• The thermowell stem shape can be straight or reduced for fast response time.
• Extension, immersion length and reduced length as well as the bar dimensions can be chosen according to process requirements.
• A wide choice of standard materials is available.
• Special versions can be manufactured according to specification.
• Different grades of surface finishing are available.
TI00230T/02/EN 71197163
Page 2

Technical data

TA562

Hexagonal bar

Connection to thermometer

Process connection

Tip

Surface

Wrench: 27 mm (1.06 in)
Outer diameter (OD): 15 mm for G½" process connection
16 mm for ½" NPT process connection16 mm for M20x1.5 process connection22 mm for ¾" NPT process connection
Standard bore diameter: 6.5 or 10 mm (0.26 or 0.39 in)
Standard material: AISI304, AISI316Ti, AISI316, AISI316L
Threaded:
Threaded:
Bottom shape:
Bottom thickness: 6.35 mm (0.25 in)
Finishing: 0.8 micron - standard
½" NPT, G½" (½" BSP) or M20x1.5 - female
½" NPT, ¾" NPT
flat
1.6 micron
, G½" or M20x1.5
2 Endress+Hauser
Page 3
TA562
NPT
ØF
Q1
A
U
T
R
Q2
D
Gas
Q1
A
U
T
Q2
D
ØF
R
M20x1.5
20 (0.78)
20 (0.78)
Wr. 27
Wr. 27

Mechanical construction

A0019018-EN
Pos.-No. Description
A Total length (A=T+U)
U Immersion length
T Extension length
R Thermowell tip length
Q1 Outside diameter
Q2 Reduced diameter
ØF Bore diameter
D Bottom thickness

Gasket For cylindrical threads (M20x1.5, G½") a gasket must be used to seal the connection.

Possible gasket dimensions:
• G½": gasket 26x21.3x1.5 copper
• M20x1.5: gasket 24x20.3x1.5 copper
The material of the gasket has to be resistant against the process medium. The gaskets are not part of the delivery.
Endress+Hauser 3
Page 4

Ordering information

Instruments International
Endress+Hauser Instruments International AG Kaegenstrasse 2 4153 Reinach Switzerland
Tel.+41 61 715 81 00 Fax+41 61 715 25 00 www.endress.com info@ii.endress.com
Detailed ordering information is available from the following sources:
•In the Product Configurator on the Endress+Hauser website: www.endress.com this product
• From your Endress+Hauser Sales Center: www.endress.com/worldwide
Product Configurator - the tool for individual product configuration:
• Up-to-the-minute configuration data
• Depending on the device: Direct input of measuring point-specific information such as measuring range or operating language
• Automatic verification of exclusion criteria
• Automatic creation of the order code and its breakdown in PDF or Excel output format
• Ability to order directly in the Endress+Hauser Online Shop
Select countryInstruments → Select device→ Product page function: Configure