• Holder can be installed on the floor, wall, coping stone or rail
• Can be adapted to ambient conditions
• Sensor installation on a cantilever arm with chain, fixed
immersion pipe or free swinging installation
• Introduces sensors into the process safely and reliably
• Float version available for variable levels
• Holder largely adjustable in terms of height, extension and
orientation
• Extensible and easy to retrofit
• Available as stainless steel or plastic version
• Captive threaded joints
• Easy to install and service
Page 2
Function and system design
1
2
3
4
6
7
5
Flexdip CYH112
Measuring system
A complete measuring system consists of:
• CYH112 holder
• Assembly, e.g. CYA112
• Transmitter, e.g. Liquiline CM44
• Sensor, e.g. CUS71D
1Measuring system with CYH112 holder
1Main pipe secured to floor
2Transmitter
3Protective cover
4Transverse pipe with fastening elements
5Hook-and-loop cable ties
6Chain
7CPA111 assembly
The holder system permits any combination of the components.
A0010865
The main pipe is suitable for mounting a transmitter with a weather protection cover. A junction box
and a surge arrester can additionally be mounted on the weather protection cover. The holes for
mounting must be drilled by the customer on site for this purpose.
The transverse pipe is used to position the sensors with regard to the distance from the wall and the
immersion location. The assembly is used to adjust the immersion depth and to securely position the
sensor in the medium. Hook-and-loop cable ties are preferably used for routing the sensor cable on
the holder (see the Product structure). Cable routing for the power supply must be implemented by
the customer onsite.
2Endress+Hauser
Page 3
Flexdip CYH112
The following assemblies can be used:
• Flexdip CYA112
• Dipfit W CLA111
• Dipfit W CPA111
• Existing assemblies that meet the requirements of the CYH112 holder as chain or fixedinstallation assemblies (weight, dimensions, lock)
Elements
The holder consists of the two basic elements - the main pipe and the transverse pipe - as well as the
functional components (e.g. multifunctional clamp ring). This permits a wide variety of
configurations to suit different installation requirements.
Main elements
Main pipeØ 40 mm (1.6 in) , lengths: 500 mm (19.7 in), 1000 mm (39.4 in), 1800 mm (70.9 in)
Transverse pipe Ø 40 mm (1.6 in), lengths: 500 mm (19.7 in), 1000 mm (39.4 in), 1500 mm (59.1 in)
ChainLength: 5 m (16.4 ft)
The chain is supplied with 2 multifunctional clamp rings and 1 triangular carabiner (secures the
chain). The open ends of the main pipe and transverse pipe are covered by caps. The main pipe
remains open at the end.
Endress+Hauser3
Page 4
Functional components
1
2
3
4
5
6
7
8
9
Flexdip CYH112
A0010858
2Functional components for the CYH112 holder
1Base
2Cross clamp
3Multifunctional clamp ring
4Pendulum holder with pendulum adapter
5Flange clamp
6Rail mounting
7Immersion pipe tray
8Triangular carabiner (secures the chain)
9Quick-action clamp
Base
The base is used to:
• Mount an upright post on the floor
• Mount a transverse pipe on a wall
Cross clamp
Two pipes can be joined at an angle of 90° with the cross clamp.
Multifunctional clamp ring
The multifunctional clamp ring has the following functions:
• For holders with a chain, the multifunctional clamp ring is used as the chain outlet on the basin
side. On the stand side, the multifunctional clamp ring is used to secure the chain in conjunction
with the triangular carabiner.
• In the case of the main pipe and transverse pipe, the working height on the main pipe can be
adjusted with the multifunctional clamp ring.
• On main pipes and transverse pipes, the multifunctional clamp ring acts as an anti-slip lock.
Triangular carabiner
The chain is secured with the triangular carabiner.
4Endress+Hauser
Page 5
Flexdip CYH112
Quick-action clamp as retrofit kit
• Allows user-friendly operation of the cross clamp and flange clamp for the quick extension,
retraction and rotation of the transverse pipe. The pipe can therefore be clamped without any
tools.
• Facilitates sensor maintenance work with rail mounting.
Pendulum holder
• Holds the assembly while still permitting assembly movement.
• For rail mounting, the holder is reduced to a pendulum holder with a cross clamp. This permits
pendulum movements in both axes.
3Pendulum movements in both axes
Flange clamp
Is used to mount a pipe. The pipe can be readjusted and repositioned after releasing the clamping
elements.
A0010906
Endress+Hauser5
Page 6
Versions
4
2
1
3
Upright post for transmitter
Flexdip CYH112
A0011212
4Upright post for transmitter
1Weather protection cover (not included in delivery)
2Transmitter (not included in delivery)
3Main pipe 1800 mm (70.9 in)
4Base for floor mounting
Order structure information: main pipe with floor mounting
Order code: CYH112-AB60A11A1
6Endress+Hauser
Page 7
Flexdip CYH112
1
2
3
4
5
4
6
7
Main pipe for floor mounting with fixed holder
A0011046
5Main pipe for floor mounting with fixed holder
1Base for floor mounting
2Main pipe 1800 mm (70.9 in)
3Multifunctional clamp ring
4Cross clamp
5Transverse pipe 1000 mm (39.4 in)
6Additional multifunctional clamp ring (not included in delivery)
7CYA112 assembly (not included in delivery)
Order structure information: main pipe for floor mounting, transverse pipe
Order code: CYH112-AB60B50D1
The version is suitable for attaching a fixed assembly. Here, the multifunctional clamp ring (item 3)
serves as a support for the transverse pipe. The additional multifunctional clamp ring (item 6) acts as
an anti-slip lock.
Endress+Hauser7
Page 8
Main pipe for floor mounting with chain retainer
1
2
3
4
5
6
7
3
3
Flexdip CYH112
A0011045
6Main pipe for floor mounting with chain retainer
1Base for floor mounting
2Main pipe 1800 mm (70.9 in)
3Multifunctional clamp ring
4Cross clamp
5Transverse pipe 1000 mm (39.4 in)
6Triangular carabiner
7Chain
Order structure information: main pipe for floor mounting, transverse pipe, chain
Order code: CYH112-AB60B50B1
The triangular carabiner secures the chain at the end of the pipe. The immersion depth of the
assembly can be adjusted by adjusting the triangular carabiner.
8Endress+Hauser
Page 9
Flexdip CYH112
1
2
3
4
Wall mounting with transverse pipe and fixed holder
A0011054
7Wall mounting with transverse pipe and fixed holder
1Base
2Transverse pipe 500 mm (19.7 in)
3Cross clamp
4CYA112 assembly (not included in delivery)
Order structure information: no main pipe, transverse pipe with wall mounting
Order code: CYH112-AA11C30D1
The version is suitable for attaching a fixed assembly.
Endress+Hauser9
Page 10
Coping stone mounting with chain retainer
1
2
3
4
2
5
6
Flexdip CYH112
A0038623
8Coping stone mounting with chain retainer
1Triangular carabiner
2Multifunctional clamp ring
3Flange clamp
4Transverse pipe 1000 mm (39.4 in)
5Chain
6CYA112 assembly (not included in delivery)
Order structure information: no main pipe, transverse pipe with coping stone mounting
Order code: CYH112-AA11D50B1
The version is suitable for an assembly suspended from a chain. The triangular carabiner secures the
chain at the end of the pipe. The immersion depth of the assembly can be adjusted by adjusting the
triangular carabiner.
10Endress+Hauser
Page 11
Flexdip CYH112
1
2
3
4
Coping stone mounting with immersion pipe
A0038624
9Coping stone mounting with immersion pipe
1Flange clamp
2Transverse pipe 1000 mm (39.4 in)
3Cross clamp
4CYA112 assembly (not included in delivery)
Order structure information: no main pipe, transverse pipe with coping stone mounting
Order code: CYH112-AA11D50D1
The version is suitable for attaching a fixed assembly.
Endress+Hauser11
Page 12
Main pipe on rail with chain retainer
7
1
2
3
1
4
1
5
6
6
Flexdip CYH112
A0011048
10Main pipe on rail with chain retainer
1Multifunctional clamp ring
2Transverse pipe 500 mm (19.7 in)
3Cross clamp
4Triangular carabiner
5Main pipe 1800 mm (70.9 in)
6Flange clamp
7Chain
Order structure information: main pipe with 1 or 2 flange clamps for rail mounting (depending
on load), transverse pipe, chain
Order code: CYH112-AF60B30B1
12Endress+Hauser
Page 13
Flexdip CYH112
5
1
2
3
1
4
Transverse pipe on rail with chain retainer
A0038627
11Transverse pipe on rail with chain retainer
1Multifunctional clamp ring
2Transverse pipe 500 mm (19.7 in)
3Flange clamp
4Triangular carabiner
5Chain
Order structure information: no main pipe, transverse pipe with rail mounting, chain
Order code: CYH112-AA11E30B1
Endress+Hauser13
Page 14
Transverse pipe on rail with immersion pipe
3
2
1
4
5
Flexdip CYH112
A0038687
12Transverse pipe on rail with immersion pipe
1Cross clamp
2Flange clamp
3Transverse pipe 500 mm (19.7 in)
4Triangular carabiner (not included in delivery)
5CYA112 assembly (not included in delivery)
Order structure information: no main pipe, transverse pipe with rail mounting
Order code: CYH112-AA11E30D1
The version is suitable for attaching a fixed assembly.
14Endress+Hauser
Page 15
Flexdip CYH112
1
2
Rail mounting with angled position of immersion pipe
A0011049
13Rail mounting with angled position of immersion pipe
1Flange clamp
2CYA112 assembly (not included in delivery)
Order structure information: no main pipe, no transverse pipe
Order code: CYH112-AE11A11A1
The version is suitable for attaching a fixed assembly which is mounted on a rail at an angle.
Endress+Hauser15
Page 16
Pendulum holder on rail with immersion pipe
1
2
3
Flexdip CYH112
A0011047
14Pendulum holder on rail with immersion pipe
1Cross clamp
2Pendulum holder
3CYA112 assembly (not included in delivery)
Order structure information: no main pipe, no transverse pipe
Order code: CYH112-AA11A11E1
The version is suitable for attaching an assembly that is mounted on the rail via the pendulum
holder. The assembly can also swing in the direction indicated. For this purpose, the holder for the
cross clamp is set to the "Free run" position.
16Endress+Hauser
Page 17
Flexdip CYH112
2
1
3
Rail mounting with float
A0011051
15Rail mounting with float
1Pendulum holder
2Cross clamp
3CYA112 assembly with float (not included in delivery)
Order structure information: no main pipe, no transverse pipe, suitable for attaching an
assembly
Order code: CYH112-AA11A11E1
Rail mounting with a float is suitable for:
• Varying liquid levels
• Places of measurement at a distance from the basin rim
The version is suitable for attaching an assembly that is mounted on the rail via the pendulum
holder. The pendulum holder allows the assembly to follow the water level with the float.
The sensor is carried by the float. For service purposes (e.g. sensor maintenance), simply take
the assembly by the pendulum holder and pull it to the basin rim to retrieve the sensor from the
medium. One-man operation is therefore easily possible.
Endress+Hauser17
Page 18
Coping stone mounting with float
2
1
3
16Coping stone mounting with float
1Pendulum holder
2Cross clamp
3CYA112 assembly with float (not included in delivery)
Flexdip CYH112
A0011213
Order structure information: no main pipe, no transverse pipe
Order code: CYH112-AA11A11F1
The version is suitable for attaching an assembly that is mounted on a coping stone via the
pendulum holder. The pendulum holder allows the assembly to follow the water level with the float.
18Endress+Hauser
Page 19
Flexdip CYH112
9
8
2
3
1
4
2
5
7
2
3
1
4
2
5
6
Expanding an existing installation
Potential equalization
17Second transverse pipe with assembly suspended from a chain
1Triangular carabiner
2Multifunctional clamp ring
3Cross clamp
4Transverse pipe
5Chain
6CYA112 assembly (not included in delivery)
7CPA111 assembly (not included in delivery)
8Main pipe (not included in delivery)
9Base (not included in delivery)
Order code: CYH112-AA11B50B1
A0011251
Power supply
Potential equalization must be implemented at the place of installation. All electrically conductive
parts must be interconnected.
If using the pendulum holder, the electrically conductive connection between the transverse pipe or
rail and the assembly holder (cross clamp) must be established at the place of installation.
Endress+Hauser19
Page 20
Installation
kg
10
1200
1000
lbs
22
39.4
47.2
5
4
0
11
8.8
mm
inch
500
19.7
0
6.5
14.3
750
29.5
Flexdip CYH112
Installation instructions
The maximum extension depends on the suspended load (weight of immersion pipe, assembly
and cable). See the following diagram for this purpose:
A0010837
18Extension as a function of the suspended load
The maximum permitted load when mounting on a rail and using a pendulum holder with a
pendulum adapter is 5 kg (11 lb). Potential equalization must be implemented at the place of
installation. All electrically conductive parts must be interconnected.
Cable
The cable to the sensor is routed outside along the pipe. Hook-and-loop cable ties can be ordered as
accessories to secure the cable.
Cable routing for the power supply must be implemented by the customer onsite.
20Endress+Hauser
Page 21
Flexdip CYH112
1200 (47.2)
1200 (47.2)
Dimensions
Mounting the holder
Ambient temperature range
A0010838
19Dimensions with maximum extension. Dimensions: mm (in)
The values indicated are valid for floor, wall and rail mounting.
For detailed information on mounting the holder, see Operating Instructions BA00430
Environment
-20 to 60 °C (-4 to 140 °F)
Endress+Hauser21
Page 22
Design, dimensions
1200 (47.2)
1200 (47.2)
Flexdip CYH112
Mechanical construction
Dimensions
A0010838
20Dimensions with maximum extension. Dimensions: mm (in)
The values indicated are valid for floor, wall and rail mounting.
Main pipeØ 40 mm (1.6 in), lengths: 500 mm (19.7 in), 1000 mm (39.4 in),1800 mm (70.9 in)
Transverse pipe Ø 40 mm (1.6 in), lengths: 500 mm (19.7 in), 1000 mm (39.4 in), 1500 mm (59.1 in)
Chain5 m (16.4 ft)
22Endress+Hauser
Page 23
Flexdip CYH112
150(5.91)
150
(5.91)
120
(4.72)
120(4.72)
12(0.47)
48.7
(1.92)
5 (0.2)
200
(7.87)
42.1(1.66)
41.5(1.63)
42(1.65)
50(1.97)
160
(6.30)
>
40
(1.57)
111 (4.37)
47 (1.85)
110 (4.33)
3 (0.12)
85 (3.35)
Ø 40
(1.57)
25 (0.98)
43
(1.69)
60 (2.36)
37.5 (1.48)
Base plate
21Dimensions of the base. Dimensions: mm (in)
The minimum distance between the bores and the basin rim is 40 mm (1.6 in).
Flange clamp
22Dimensions of the flange clamp. Dimensions: mm (in)
A0035830
A0035771
Endress+Hauser23
Page 24
80 (3.15)
80 (3.15)
Ø 9 (0.35)
23Dimensions of the boreholes of the flange clamp. Dimensions: mm (in)
Ø 40
(1.57)
96 (3.78)
92 (3.62)
3 (0.12)
43 (1.69)
Cross clamp
Flexdip CYH112
A0010885
A0038695
24Dimensions of cross clamp. Dimensions: mm (in)
24Endress+Hauser
Page 25
Flexdip CYH112
79 (3.11)
50 (1.97)
12 (0.47)
12 (0.47)
40
71 (2.80)
85 (3.35)
68
161 (6.34)
153 (6.02)
61 (2.40)
118 (4.65)
60 (2.36)
25 (0.98)
9
(0.35)
67 (2.64)
26 (1.02)
(2.68)
(1.57)
Pendulum holder
A0011252
25Dimensions of the pendulum adapter. Dimensions: mm (in)
Pendulum holder
A0038694
26Dimensions of pendulum holder (without cross clamp). Dimensions: mm (in)
Endress+Hauser25
Page 26
Rail mounting
57 (2.24)
111 (4.37)
47 (1.85)
110 (4.33)
3 (0.12)
85 (3.35)
181 (7.13)
60 (2.36)
37.5 (1.48)
Handrail cross-sectionSquare or circular
Edge length or diameter30 to 60 mm (1.2 to 2.4 in)
Alignment for circular handrailsAny
Alignment for square handrailsVertical or horizontal
Flexdip CYH112
Weight
Materials
27Dimensions for rail mounting. Dimensions: mm (in)
* The flange clamp, cross clamp and base clamping element are made from the material indicated
with the exception of the clamps in the clamping device, which are made from stainless steel 1.4301
or 1.4305 (AISI 304). The pendulum holder is made from the material indicated with the exception
of the shaft and the clamps in the clamping device, which are made from stainless steel 1.4301 or
1.4305 (AISI 304).
Certificates and approvals
Ex approval
Scope of delivery
Product page
Product Configurator
The CYH112 holder may also be used in hazardous areas in Zone 1 and 2.
The holder does not fall within the scope of ATEX Directive 2014/34/EU as it does not have a
potential source of ignition of its own. Consequently, the holder does not bear ATEX identification
marking. Potential equalization must be implemented as described in the "Installation conditions"
section.
Ordering information
The scope of delivery comprises:
• Ordered version of assembly holder
• Operating Instructions
If you have any queries:
‣
Please contact your supplier or local sales center.
www.endress.com/cyh112
On the product page there is a Configure button to the right of the product image.
1. Click this button.
The Configurator opens in a separate window.
2. Select all the options to configure the device in line with your requirements.
In this way, you receive a valid and complete order code for the device.
3. Export the order code as a PDF or Excel file. To do so, click the appropriate button on the right
above the selection window.
For many products you also have the option of downloading CAD or 2D drawings of the
selected product version. Click the CAD tab for this and select the desired file type using
picklists.
Accessories
The following are the most important accessories available at the time this documentation was
issued.
For accessories not listed here, please contact your Service or Sales Center.
‣
Endress+Hauser27
Page 28
Flexdip CYH112
B
B
B-B
Ø 86 (3.39)
Ø 80 (3.15)
100°
60 (2.36)
76.8
(3.02)
Ø 71.45
(2.81)
8 (0.31)
Ø 8 (031)
Ø 86 (3.39)
Ø 50 (1.97)
Ø 40 (1.57)
5 (0.2)
15 (0.59)
42
(1.65)
24.1
(0.95)
11.2 (0.44)
25
(0.98)
41.5
(1.63)
35
(1.83)
60 (2.36)
29.5
(1.16)
Dipfit CLA111
• Immersion assembly for open and closed vessels with flange DN 100
• Product Configurator on the product page: www.products.endress.com/cla111
Technical Information TI00135C
Dipfit CPA111
• Immersion and installation assembly made of plastic for open and closed vessels
• Product Configurator on the product page: www.endress.com/cpa111
Technical Information TI00112C
Flexdip CYA112
• Immersion assembly for water and wastewater
• Modular assembly system for sensors in open basins, channels and tanks
• Material: PVC or stainless steel
• Product Configurator on the product page: www.endress.com/cya112
Technical Information TI00432C
Multifunctional clamp ring
• In the case of a chain retainer, the rear multifunctional clamp ring keeps the chain fixed in place.
• In the case of the main pipe and transverse pipe, adjust the working height on the main pipe with
the multifunctional clamp ring.
• The multifunctional clamp ring acts as an anti-slip lock on transverse pipes, main pipes and on
assemblies.
• Material: POM - GF
• Order number: 71092049
28Multifunctional clamp ring. Dimensions: mm (in)
A0035699
28Endress+Hauser
Page 29
Flexdip CYH112
47 (1.85)
73.5
(2.89)
10 (0.39)
31
(1.22
)
3
(0.12)
65 (2.56)
93.5 (3.68)
100
(3.94)
48 (1.89)
AA-A
A
89.5 (3.52)
23 (0.91)
9.1
(0.36)
B
B
B-B
9
(0.35)
55 (2.17)
79.9 (3.15)
9 (0.35)
M8
6 (0.24)
15
(0.59)
12
(0.47)
16 (0.63)
7
(0.28)
66.4 (2.61)
Immersion pipe tray
• Is used to hold the immersion pipe during maintenance work
• Material: stainless steel 1.4404 (AISI 316L)
• Order number: 71092054
29Immersion pipe tray. Dimensions: mm (in)
Quick-action clamp
• Replaces the threaded joint
• Material: stainless steel 1.4301 (AISI 304); handle: PA
• Order number: 71092050
Triangular carabiner
• Is used to secure the chain
• Material: stainless steel, quality V4A
• Order number: 71092052
A0035703
Endress+Hauser29
Page 30
Flexdip CYH112
58 (2.28)
46 (1.81)
Ø
6
(0.24)
10.9
(0.43)
320 (12.6)
270 (10.6)
300 (11.8)
A0035705
30Triangular carabiner. Dimensions: mm (in)
Hook-and-loop cable ties (set of 4)
• Is used to secure the cables
• Material: PE/PA (polyethylene/polyamide)
• Order number: 71092051
Allen key
• Across flats: AF 6
• Order number: 71092057
Pipe protection cap
• Material: PE (polyethylene)
• Order number: 71092053
Weather protection cover CYY101 for field devices
• Absolutely essential for field installation
• Material: stainless steel 1.4301 (AISI 304)
• Order number CYY101-A
• Mounting kit to secure the CYY101 weather protection cover on vertical or horizontal pipes with a
diameter of up to 62 mm (2.44 in) Order No. 50062121
31Weather protection cover for field devices. Dimensions: mm (in)
30Endress+Hauser
A0035834
Page 31
Flexdip CYH112
M6
55
(2.17)
66
(2.60)
70 (2.76)
Ø 8
(0.31)
30
(1.18)
90 (3.54)
A0005091
32Circular post mounting for CYY101. Dimensions: mm (in)
Overvoltage protection
HAW56X surge arrester and associated installation material
Quick-action clamp
Order number: 71092050
Nylon chain
• Minimum length 5 m (16.4 ft)
• Order number: 71130145
Endress+Hauser31
Page 32
www.addresses.endress.com
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.