Sensors with Memosens protocol
For conductive measurement of conductivity in
liquids
EU Declaration of ConformityCondumax CLS15D/16D/21D
EU Declaration of Conformity
ATEX / NEPSI II 1G Ex ia IIC T3/T4/T6 Ga, IECEx Ex ia IIC T3/T4/T6 Ga
2Endress+Hauser
Condumax CLS15D/16D/21DEU Declaration of Conformity
ATEX/NEPSI II 3G Ex ic IIC T3/T4/T6 Gc
Endress+Hauser3
Table of contentsCondumax CLS15D/16D/21D
Table of contents
1About this document ........... 5
1.1Warnings ........................... 5
1.2Symbols ............................ 5
2Basic safety instructions ....... 6
2.1Requirements for personnel ........... 6
2.2Designated use ...................... 6
2.3Workplace safety .................... 6
2.4Operational safety ................... 7
2.5Product safety ....................... 7
3Incoming acceptance and
product identification .......... 9
3.1Incoming acceptance ................. 9
3.2Product identification ................ 10
3.3Scope of delivery .................... 11
3.4Certificates and approvals ............ 11
4Installation .................... 13
4.1Mounting the sensor ................ 13
4.2Post-installation check ............... 17
5Electrical connection .......... 17
5.1Quick wiring guide .................. 18
5.2Connecting the sensor ............... 20
5.3Ensuring the degree of protection ..... 20
5.4Post-connection check ............... 20
6Commissioning ................ 21
7Maintenance .................. 21
8Repair .......................... 22
8.1Sealing ring replacement and
recalibration (CLS16D only) .......... 22
8.2Return ............................ 23
8.3Disposal ........................... 23
9Technical data ................. 24
9.1Input .............................. 24
9.2Performance characteristics .......... 25
9.3Environment ....................... 26
9.4Process ............................ 26
9.5Mechanical construction ............. 28
4Endress+Hauser
Condumax CLS15D/16D/21DAbout this document
1 About this document
1.1 Warnings
Structure of informationMeaning
DANGER
L
Causes (/consequences)
If necessary, Consequences of noncompliance (if applicable)
Corrective action
‣
WARNING
L
Causes (/consequences)
If necessary, Consequences of noncompliance (if applicable)
Corrective action
‣
CAUTION
L
Causes (/consequences)
If necessary, Consequences of noncompliance (if applicable)
Corrective action
‣
NOTICE
Cause/situation
If necessary, Consequences of noncompliance (if applicable)
Action/note
‣
This symbol alerts you to a dangerous situation.
Failure to avoid the dangerous situation will result in a fatal or serious injury.
This symbol alerts you to a dangerous situation.
Failure to avoid the dangerous situation can result in a fatal or serious injury.
This symbol alerts you to a dangerous situation.
Failure to avoid this situation can result in minor or more serious injuries.
This symbol alerts you to situations which may result in damage to property.
1.2 Symbols
SymbolMeaning
Additional information, tips
Permitted or recommended
Not permitted or not recommended
Reference to device documentation
Reference to page
Reference to graphic
Result of a step
Endress+Hauser5
Basic safety instructionsCondumax CLS15D/16D/21D
2 Basic safety instructions
2.1 Requirements for personnel
• Installation, commissioning, operation and maintenance of the measuring system may be
carried out only by specially trained technical personnel.
• The technical personnel must be authorized by the plant operator to carry out the specified
activities.
• The electrical connection may be performed only by an electrical technician.
• The technical personnel must have read and understood these Operating Instructions and
must follow the instructions contained therein.
• Faults at the measuring point may only be rectified by authorized and specially trained
personnel.
Repairs not described in the Operating Instructions provided must be carried out only
directly at the manufacturer's site or by the service organization.
2.2 Designated use
The conductivity sensors are designed for the conductive measurement of the conductivity of
liquids.
They are used in the following fields:
SensorApplicationsHazardous areas
Condumax CLS15D Measurements in pure and ultrapure waterApproved for Ex zone 0
Condumax CLS16D Measurements in pure and ultrapure water with hygienic requirements Approved for Ex zone 0
Condumax CLS21D Measurements in media with medium or high conductivityApproved for Ex zone 0
Use of the device for any purpose other than that described, poses a threat to the safety of
people and of the entire measuring system and is therefore not permitted.
The manufacturer is not liable for damage caused by improper or non-designated use.
2.3 Workplace safety
As the user, you are responsible for complying with the following safety conditions:
• Installation guidelines
• Local standards and regulations
• Regulations for explosion protection
Electromagnetic compatibility
• The product has been tested for electromagnetic compatibility in accordance with the
applicable international standards for industrial applications.
• The electromagnetic compatibility indicated applies only to a product that has been
connected in accordance with these Operating Instructions.
6Endress+Hauser
Condumax CLS15D/16D/21DBasic safety instructions
2.4 Operational safety
Before commissioning the entire measuring point:
1.Verify that all connections are correct.
2.Ensure that electrical cables and hose connections are undamaged.
3.Do not operate damaged products, and protect them against unintentional operation.
4.Label damaged products as defective.
During operation:
If faults cannot be rectified:
‣
products must be taken out of service and protected against unintentional operation.
2.5 Product safety
2.5.1 State-of-the-art technology
The product is designed to meet state-of-the-art safety requirements, has been tested, and
left the factory in a condition in which it is safe to operate. The relevant regulations and
international standards have been observed.
2.5.2 Electrical equipment in hazardous areas
ATEX/NEPSI II 1G Ex ia IIC T3/T4/T6 Ga
• The Memosens inductive sensor-cable connection system is suitable for use in hazardous
areas in accordance with EC type examination certificate BVS 04 ATEX E 121 X. The
corresponding EC declaration of conformity is part of this document.
• The certified conductivity sensors CLS15D/CLS16D/CLS21D may only be connected via the
measuring cable CYK10-G/I*** to the certified intrinsically safe digital sensor output
circuits of measuring device Liquiline M CM42-KE/F/G/I/J********** in accordance with
EC type-examination certificate TÜV 13 ATEX 7459 X.
• The electrical connection must be made according to the wiring diagram of the transmitter.
• Metallic process connection parts must be mounted at the mounting location
electrostatically conductive (< 1 MΩ).
• The CLS15D-type sensors with non-metal process connections and the CLS21D-type
sensors may only be employed for measurement in liquids with a minimum conductivity of
10 nS/cm.
• The CLS15D-type sensors with non-metal process connections may not be operated under
process conditions in which electrostatic charging of the sensor, and particularly of the
electrically insulated outer electrode, is likely to occur.
• Measuring cable CYK10-G/I*** and its terminal head must be protected against
electrostatic charging if it is run through Zone 0.
• The maximum permitted cable length is 100 m.
• Ex versions of digital sensors with Memosens technology are indicated by an orange-red
ring.
• Full compliance with regulations for electrical systems in hazardous areas (e.g. EN/IEC
60079-14) is mandatory when using the devices and sensors.
Endress+Hauser7
Basic safety instructionsCondumax CLS15D/16D/21D
Temperature classes
NameTypeMedium temp. Ta for temperature class (Tn)Cat.
CondumaxCLS15D- A**G -20 °C ≤ Ta ≤ +135 °C (T3)
-20 °C ≤ Ta ≤ +120 °C (T4)
-20 °C ≤ Ta ≤ +70 °C (T6)
CondumaxCLS15D- B/L**G -20 °C ≤ Ta ≤ +135 °C (T3)
-20 °C ≤ Ta ≤ +100 °C (T4)
-20 °C ≤ Ta ≤ +50 °C (T6)
CondumaxCLS16D- **** G -5 °C ≤ Ta ≤ +135 °C (T3)
-5 °C ≤ Ta ≤ +115 °C (T4)
-5 °C ≤ Ta ≤ +65 °C (T6)
CondumaxCLS21D- *** G -20 °C ≤ Ta ≤ +135 °C (T3)
-20 °C ≤ Ta ≤ +115 °C (T4)
-20 °C ≤ Ta ≤ +65 °C (T6)
II 1G
II 1G
II 1G
II 1G
If the specified medium temperatures are complied with, temperatures that are not permitted
for the respective temperature class will not occur on the equipment.
ATEX/NEPSI II 3G Ex ic IIC T3/T4/T6 Gc
• The Memosens inductive sensor-cable connection system is suitable for use in hazardous
areas, Zone 2. The corresponding EU declaration of conformity is part of this document.
• The certified conductivity sensors CLS15D / CLS16D / CLS21D may only be connected via
the measuring cable CYK10-V*** to the certified intrinsically safe digital sensor output
circuits of measuring device Liquiline M CM42-KV*********.
• The electrical connection must be made according to the wiring diagram of the transmitter.
• Metallic process connection parts must be mounted at the mounting location
electrostatically conductive (< 1 MΩ).
• The CLS15D-type sensors with non-metal process connections and the CLS21D-type
sensors may only be employed for measurement in liquids with a minimum conductivity of
10 nS/cm.
• The CLS15D-type sensors with non-metal process connections may not be operated under
process conditions in which electrostatic charging of the sensor, particularly of the
electrically insulated outer electrode, is likely to occur.
• The maximum permitted cable length is 100 m.
• Full compliance with regulations for electrical systems in hazardous areas (EN/IEC
60079-14) is mandatory when using the devices and sensors.
Temperature classes
NameTypeMedium temp. Ta for temperature class (Tn)Cat.
CondumaxCLS15D- A** V -20 °C ≤ Ta ≤ +135 °C (T3)
-20 °C ≤ Ta ≤ +120 °C (T4)
-20 °C ≤ Ta ≤ +70 °C (T6)
CondumaxCLS15D- B/L**V -20 °C ≤ Ta ≤ +135 °C (T3)
-20 °C ≤ Ta ≤ +100 °C (T4)
-20 °C ≤ Ta ≤ +50 °C (T6)
8Endress+Hauser
II 3G
II 3G
Condumax CLS15D/16D/21DIncoming acceptance and product identification
NameTypeMedium temp. Ta for temperature class (Tn)Cat.
CondumaxCLS16D- **** V -5 °C ≤ Ta ≤ +135 °C (T3)
-5 °C ≤ Ta ≤ +115 °C (T4)
-5 °C ≤ Ta ≤ +65 °C (T6)
CondumaxCLS21D- *** V -20 °C ≤ Ta ≤ +135 °C (T3)
-20 °C ≤ Ta ≤ +115 °C (T4)
-20 °C ≤ Ta ≤ +65 °C (T6)
II 3G
II 3G
If the specified medium temperatures are complied with, temperatures that are not permitted
for the respective temperature class will not occur on the equipment.
FM/CSA IS/NI Cl.1 Div.1&2 Gr. A-D
Observe the documentation and the control drawings of the transmitter.
3 Incoming acceptance and product identification
3.1 Incoming acceptance
1.Verify that the packaging is undamaged.
Notify the supplier of any damage to the packaging.
Keep the damaged packaging until the issue has been resolved.
2.Verify that the contents are undamaged.
Notify the supplier of any damage to the delivery contents.
Keep the damaged goods until the issue has been resolved.
3.Check that the delivery is complete and nothing is missing.
Compare the shipping documents with your order.
4.Pack the product for storage and transportation in such a way that it is protected
against impact and moisture.
The original packaging offers the best protection.
Make sure to comply with the permitted ambient conditions.
If you have any questions, please contact your supplier or your local Sales Center.
Endress+Hauser9
Incoming acceptance and product identificationCondumax CLS15D/16D/21D
3.2 Product identification
3.2.1 Type code for versions with explosion protection
NameTypeVersion
CondumaxCLS15D
CLS16D
CLS21D
NameTypeVersion
CondumaxCLS15D
CLS16D
CLS21D
NameTypeVersion
CondumaxCLS15D
CLS16D
CLS21D
-
*
-
**
-
*
Process connections,
materials not Ex-relevant
-
*
-
**
-
*
Process connections,
materials not Ex-relevant
-
*
-
**
-
*
Process connections,
materials not Ex-relevant
**
**
**
**
**
**
**
**
**
G
G
G
For use in hazardous areas, ATEX/NEPSI II 1G Ex ia IIC
T3/T4/T6 Ga, IECEx Ex ia IIC T3/T4/T6 Ga
O
O
O
For use in hazardous areas, FM/CSA IS/NI Cl I Div.1&2
Gr. A-D
V
V
V
For use in hazardous areas, ATEX/NEPSI II 3G Ex ic IIC
T3/T4/T6 Gc
3.2.2 Nameplate
The nameplate provides you with the following information on your device:
• Manufacturer identification
• Order code
• Serial number
• Ambient and process conditions
• Safety information and warnings
• Cell constant (nominal value)
• Degree of protection
• Ex labeling on hazardous area versions
Compare the information on the nameplate with the order.
‣
3.2.3 Product identification
Product page
www.endress.com/cls15d
www.endress.com/cls16d
10Endress+Hauser
Loading...
+ 22 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.