Emerson Trellis Site Manager Brochures and Data Sheets

Trellis
TM
Site Manager
real-time infrastructure optimization
Benefits
• Ensure business-critical
continuity with comprehensive event management and alarm notifications
• Accurately understand real-
time energy consumption (kW/ hours) and cost of operating subsystems; even exempt certain parts in calculating for a mixed-use facility
• Improve performance
efficiency and reduce risk of unplanned downtime by knowing the current and future energy needs of the data center based on historical data
• View PUE and DCIE to ensure
compliance with efficiency metrics by The Green Grid and the like
• Promote efficient and effective
use of support personnel, including site engineers and technicians, by sending them in—only when necessary
• Reduce time spent sorting
through inbox messages with an intelligent summary of priority issues
Emerson Network Power
Solution Suite
Today’s data centers must run 24/7 without fail and with the least energy consumed possible. The personnel, therefore, must ensure the health of all critical assets by acting promptly on important alarms—a difficult task as they are overwhelmed on a daily basis with frequent notifications.
Being able to limit the number of alarms will improve the efficiency of monitoring and tracking in the data center. Gaining real-time visibility into the energy consumption and operating efficiencies within the data center will also allow organizations to lower their operational costs and meet industry-approved efficiency metrics.
A new way in overcoming these challenges is provided by the Trellis™ Site Manager within the Trellis™ platform. Trellis™ Site Manager keeps systems running at peak performance and ensures maximum use of time and resources. It tracks and reports the health of facility-critical devices and provides information on power, cooling and environmental conditions, such as temperature, humidity, airflow and leak detection. Its customizable notification and threshold validation functions allow users to focus on active alarms that need to be attended to immediately, enabling the effective and efficient use of support personnel. It presents device-level data and trends and provides detailed insight into the status and environmental conditions of the data center.
The Trellis™ Site Manager is also the perfect tool to see the data center’s power usage effectiveness (PUE) and data center infrastructure efficiency (DCIE), allowing the organization to adhere to industry standards set by The Green Grid and the like. The unified and practical dashboard allows managers to view current and historical efficiency metrics as well as calculate both consumption and costs—a feature perfect for data centers that are not yet properly instrumented for measuring facility and IT load. IT managers are able to use the information gathered to maximize energy usage, minimize energy waste and reduce utility costs.
With TrellisTM Site Manager, you can:
• Collect and analyze real-time data for monitoring business-critical
infrastructure, environmental conditions and power consumption
• Send alarm notifications via SNMP, SMS or email and based on personnel shifts
• Configure and manage alarm significance so important ones are addressed first
• View facility layout and actual asset utilization
• Comply with industry-approved efficiency metrics (PUE and DCIE)
• Calculate utility cost—not just consumption—at the system and unit levels
• Customize the dashboard to exclude certain facility load parts in a mixed-use
facility
• Determine current and future energy needs based on historical data
• Highlight issues that need
immediate attention and provide real-time, meaningful information that addresses the needs of senior management
TrellisTM Site Manager
Emerson Network Power
Solution Suite
Monitor and respond to critical devices intelligently
• See device status (Normal, In Alarm, Maintenance Mode, Not Responding) on a graphical floor plan and in real time to get a
more comprehensive view of actual device health
• Configure data points for collection and assign data collection
intervals
• Categorize and visualize data via Configure, Control, Support and
Specification tabs
• Use Accelerated Polling to monitor trends during power outage
and when running on battery power for maintenance; compare load with run time to provide additional measurement of load percentage versus available battery run time
• Control and command other devices to perform actions using an
alarm as a trigger, minimizing need for personnel intervention (i.e., high temperature); gather data from any device in the system once alarm is triggered
• Real-time tracking of aisle temperature during extended power
outage via Cold Aisle Temperature Sensors and track aisle temperature or evaluate high room temperature events
• Get notifications via SNMP, SMS or email and based on working
hours of facilities personnel so alarms are addressed to the right person promptly; determine delivery based on notification states (Success, Failed or Pending)
• Provide alarm attributes, filters, transitions, views (active and
audit/calendar) as well as actions (acknowledgment, escalation, accelerations, etc.,); assign alarms and notification rules according to user role
• Use logical operators (AND, OR, NOT) to create logic between
alarms so notifications are sent only after conditions of related alarm are met; no notification sent if action is no longer needed
• Suppress alarms so users won’t need to spend time receiving
and checking notifications from devices that send erroneous, intermittent alarms
• Use Summary View to see what alarm merits immediate
attention and to see alarms side-by-side to understand their context, cause and relationship, if any
Track consumption in real time for better efficiency
• Use the unified dashboard to see real-time data, energy usage
and operating efficiency together; key information helps determine system peak performance, maximize energy usage and minimize energy waste
• Customize dashboards so users can enter data manually if the
data center is not properly instrumented for measuring total facility or IT load
• Gauge efficiency and comply with current and historical industry-
approved efficiency metrics (PUE and DCIE)
• Compute real-time power consumption (kW/hour) for a device
and determine ways to balance capacity and demand within the data center
• Eliminate readings from one or more devices when making PUE
and DCIE calculations in a mixed-use (office space + data center) data center facility
• Configure source and currency details that facilitate utility cost
calculations at the system and unit levels… so you can determine
actual costs, not just consumption
• Understand capacity usage to ensure business-critical services
are always up and running while lowering operating costs; roll out measures to improve peak performance
Emerson Network Power
EmersonNetworkPower.com
TM
Trellis
Site Manager
Emerson, Emerson Network Power, and the Emerson Network Power logo are trademarks and service marks
of Emerson Electric Co. Avocent, Trellis and the Trellis logo are trademarks and service marks of Avocent
Corporation. All other marks and logos are the intellectual propert y of their respective owners. ©2014
Emerson Electric Co. All rights reserved.