Compact Indoor and Outdoor Cell Site Solutions
Outdoor Solution With DC Power
The outdoor site solution includes the NetSure™ 211 power system and the NetXtend™ Compact 2416 cabinet. The NetXtend™ Compact 2416 is a small single sided low-cost outdoor rated aluminum enclosure with a heat exchanger cooling system.
nNEMA 3R design protects equipment from water and dust, while maintaining a cool operating environment
nNetSure™ rectifiers are designed to operate from -40 °C to +75 °C, providing 400 W output at 65 °C, suitable for harsh environmental conditions
nUL and cUL listing ensures documented performance
nGR-487-CORE Issue 3 design ensures system reliability and durability
Application
The Outdoor Solution With DC Power is ideal for inconspicuous deployment of Alternative Access Vendor (AAV) applications, mobile 2G/3G/4G cellular base stations, DAS nodes, mobile backhaul, remote power solutions, fiber (FTTx) nodes, advanced metering management (AMM) nodes or hybrid controller systems (solar, wind, etc.).
Dimensions
16.67"
24.00"
8.57"
24.00"
16.00"
Technical Specifications
Electrical |
|
System Voltage |
120 VAC single phase (nominal) |
Output Voltage |
-42 VDC to -58 VDC |
System Capacity |
19" 1 RU up to 8 A |
Rectifier Capacity |
0.4 kW @ 120 VAC |
|
|
DC Distribution |
Wallmount GMT fuse panel with (10) fuses, up to 15 A |
Controller |
SCU+ controller |
|
|
|
|
Physical Characteristics |
|
Framework Type |
NetXtend™ Compact Enclosure |
Available Space |
Up to 14 RU, 19" W |
|
|
Dimensions |
Enclosure: 24" x 24" x 16" |
(H x W x D) |
Battery tray: 22" W x 13" D |
Mounting |
Wall or H-frame, pole mount (wall-mount kit included) |
|
|
Weight, Equipped |
Enclosure: 64 lb., w/out batteries |
|
Four (4) batteries: 36 lb. total |
Access |
Front |
|
|
Environmental |
|
Climate System |
Heat Exchanger |
Operating Temp. |
-40 °C to +52 °C |
|
|
Storage Temp. |
-40 °C to +75 °C |
Relative Humidity |
100% |
|
|
EMI/RFI |
Conforms to FCC rules Part 15, Subpart B, Class B and EN55022 |
|
Class B, radiated and conducted |
Safety Compliance |
cULus 60950 Recognized, NEBS Level 3 Compliance |
|
Enclosure: cULus Listed GR-487 |
*See rectifier specification for any derating. Operating and storage temperatures for batteries installed in the battery cabinet are provided by the battery manufacturer.
Ordering Information
Emerson |
|
Emerson |
|
Number |
Description |
Number |
Description |
F2013074 |
Outdoor Solution w/DC Power |
F2014025 |
Outdoor Solution w/DC Power |
Equipped with the following: |
Equipped with the following: |
||
1 EA |
NetXtend™ Compact with heat |
1 EA |
NetXtend™ Compact with heat |
|
exchanger, NXC2416AAV1H05BB3 |
|
exchanger, NXC2416AAV1H05BB3 |
|
and slide-out shelf |
|
(no slide-out shelf) |
1 EA |
NetSure™ 211 power system |
1 EA |
NetSure™ 211 power system |
2 EA |
500 W rectifiers |
2 EA |
500 W rectifiers |
|
|
|
|
1 EA |
19" rack-mount, slide-out tray |
1 EA |
AC outlet mounting bracket |
1 EA |
AC outlet mounting bracket |
2 EA |
20 A, 120 VAC outlets |
|
|
|
|
2 EA |
20 A, 120 VAC outlets |
1 EA |
Wall-mounting kit |
1 EA |
Wall-mounting kit |
|
|
|
|
|
|
Accessories
547681 Battery, EnerSys NP12-12,12 AH bat mod, 4 EA
524855 Battery, GNB Marathon, M12V30NT, 30 AH bat mod, 4 EA
140454 Battery, C&D 12-45, 45 AH bat mod, 4 EA
095ORB-GMCSS / 0614 |
1 |
Compact Indoor and Outdoor Cell Site Solutions
Indoor Solution With DC Power
The indoor site solution combines a NetSure™ 211 -48 VDC power system with reliable rectifiers, an advanced Ethernetaccessible controller, flexible distribution and high power density. An enclosed battery cabinet is included that can be mounted on the wall or in a relay rack. A 40 A battery disconnect is included with the battery cabinet and can be connected in parallel with other cabinets to provide additional backup time.
nSupports Ethernet and SNMP communication interfaces, enabling remote control and monitoring
nNetSure™ rectifiers are designed to operate from -40 °C to +75 °C, providing
500 W output at 45 °C, suitable for harsh environmental conditions
nExtremely wide AC voltage range window, 85 VAC to 300 VAC
Application
Indoor Solution (shown without cover)
The Indoor Solution With DC Power is designed for deployment in wireless sites, central office, POP sites, co-location sites, customer premises, outdoor cabinets, CEVs, vaults or portable shelters. Specific applications include: Alternative Access Vendor (AAV), wireless backhaul and other site solutions such as, DAS, DLC, xDSL, DSLAM, FTTx electronics, broadband communications, multiplexers, LTE, WiMAX, microwave and PBX.
Dimensions
|
|
17.7" |
1.9" |
|
10.5" |
|
|
|
1.7" |
|
|
6.9" |
|
|
|
|
15.6" |
|
17.5" |
5.0" |
|
|
Technical Specifications
Electrical |
|
System Voltage |
120 VAC single phase (nominal) |
Output Voltage |
-42 VDC to -58 VDC |
|
|
System Capacity |
19" 1 RU up to 10 A |
|
|
Rectifier Capacity |
0.5 kW @ 120 VAC |
DC Distribution |
Wallmount GMT fuse panel with (10) fuses, up to 15 A |
|
|
Controller |
SCU+ controller |
|
|
Physical Characteristics |
|
Framework Type |
|
Relay rack |
|
|
|
Available Space |
1 RU 19" W |
Dimensions |
DC power system: 1.7" x 19" x 12" |
(H x W x D) |
Solution: 10.5" x 19" x 15.6" |
Mounting |
Rack or wall mount |
Weight, Equipped |
System: 35.5 lb., w/out batteries |
|
Four (4) batteries: 36 lb. total |
Access |
Front for batteries, control and distribution, rear for AC |
|
|
Environmental |
|
Climate System |
Fan-cooled front to rear |
|
|
Operating Temp. |
-40 °C to +75 °C* |
Storage Temp. |
-40 °C to +75 °C |
|
|
Relative Humidity |
0% to 95% non-condensing |
EMI/RFI |
Conforms to FCC rules Part 15, Subpart B, Class B and EN55022 |
|
Class B, radiated and conducted |
Safety Compliance |
cULus 60950 recognized NEBS Level 3 Compliance |
|
|
*See rectifier specification for any derating. Operating and storage temperatures for batteries installed in the battery cabinet are provided by the battery manufacturer.
Ordering Information
Emerson |
|
Part Number |
Description |
582136600SK010 |
Indoor Solution w/DC Power |
Equipped with the following: |
|
1 EA |
NetSure™ 211 power system |
2 EA |
500 W rectifiers |
1 EA |
19" rack-mount, slide-out tray |
1 EA |
Battery cabinet |
1 EA |
Wall mount bracket |
Accessories |
|
547681 |
Battery, EnerSys NP12-12, 12 AH bat mod, 4 EA |
2 |
095ORB-GMCSS / 0614 |