Emerson Liebert PSI-XR 1000-3000VA, Liebert PSI 1000-3000VA Brochures and Data Sheets

Page 1
Liebert® PSI
High Performance Rack-Mount UPS For Network Power Protection
Liebert PSI is a compact, line-interactive UPS system
closets and small data centers. It provides reliable
power protection for servers, critical nodes, network
workstations, large network peripherals, network
routers, bridges, and other electronic equipment.
Liebert PSI allows you to get more from your UPS and your protected equipment, with features normally found only on more expensive systems:
Up to five minutes of internal battery backup time at full load
provides ample time for an orderly shutdown of connected equipment.
Liebert PSI operates at a higher output power factor — meaning less power consumption. This results in your network running at lower power levels and lower heat levels, and ultimately provides a longer network service life.
Remote communications and shutdown options provide remote moni toring and powe r mana gement — contact closure, USB, SNMP
Liebert PSI is compliant with the Restriction of Hazardous Substances Directive (RoHS), prohibiting use of six hazardous materials manufacturing of electronics, including lead-free solder.
AC Power For Business-Critical Continuity
Ideally suited for:
PCs
Network workstations
Servers
Network closets
Large network peripherals
VoIP
Page 2
Reliable UPS ProtectionTo Keep Your Network Up And Running
The flexible design of Liebert PSI allows the UPS
to be configured as a self-standing tower or to be
rack-mounted within a 2U space. It is available in
four capacities, and both 120V or 230V models.
The UPS features an innovative line-interactive design incorporating buck/boost automatic voltage regulation technology. This protects against utility voltage fluctuation by raising and lowering utility power to the level needed by the connected equipment. It also allows the UPS to prolong battery life by maximizing its time on utility power before going to battery.
Liebert PSI Standard Features:
Flexibility:
Eight battery-backed outlets
Allows the Liebert PSI to be more flexible in accommodating additional equipment to be connected to the UPS via the 15 or 20 Amp receptacles.
Configurable input voltage window
Allows the UPS to be properly matched to the incoming utility power and adjusts its input window and transfer points to supply precisely regulated power to connected loads within the selected range. Also enables the UPS to meet the required input voltage when transferring to battery.
Rotatable Display Panel
90° rotatable LED display panel rotates 90° to make the readout of the LED display easy to see in rack or tower position.
Automatic Frequency Sensing
The UPS automatically adjusts to the input frequency, 50Hz or 60Hz.
Rack Rail Kit
These telescoping rails mount to the sides of the UPS to facilitate installation into a rackmount enclosure.
RS232 (DB-9)
Port
Voltage
Configuration
DIP Switch
Liebert
Intellislot
Port
USB
Port
RJ-45
Data Line
Connectors
Output
Circuit
Breakers
Input
Circuit
Breakers
Receptacles
2
Page 3
Optional Liebert IntelliSlot Web Card provides SNMP and web-based management
Higher Availability:
Data line surge protection
Network surge protection for equipment connected to the UPS via the RJ-45.
Advance early warning of UPS system status
The Liebert PSI offers multiple audible and visual alarms to immediately alert you to an input voltage fluctuation (buck/boost), output overload, low battery or replace battery condition.
Up to five minutes of battery backup time at full load when utility fails
Provides ample time for an orderly shutdown of connected equipment.
Full sequenced battery testing
The Liebert PSI provides a manual self­diagnostic test feature. This provides a comprehensive analysis of the condition of the batteries within the UPS and will notify you when the internal batteries need to be replaced. The battery test feature can also be programmed for automatic operation using Liebert IS-WEBRT3 card.
Surge protection
The transient voltage surge suppression (TVSS) circuitry inside the Liebert PSI provides protection for the connected equipment from incoming spikes, surges, and other power anomalies present on the incoming utility power source.
Remote emergency power off
Allows the UPS to be remotely shut down during an emergency.
Hot swappable batteries
Increase product life and provide prolonged UPS reliability. Batteries are conveniently located behind the front bezel of the unit.
Lowest Total Cost Of Ownership:
0.9 Output Power Factor
Liebert PSI operates at a higher output power factor -- meaning less power consumption. This results in your network running at lower power levels and lower heat
levels, and ultimately provides a longer network service life.
Wider input voltage window
Prolongs battery life by allowing the UPS to maximize the use of utility power before transferring to battery when
input voltage exceeds specified limits.
Reduced installation time and costs
UPS is shipped with batteries connected and charged.
Warranty Protection
Standard two-year warranty ensures UPS replacement if problems occur during the warranty period. Optional one-year and three-year extensions also available.
Multiple Choices For Communication, Shutdown And Reporting:
Contact Closure Communication Option
Automated shutdown software allows you to monitor communication between the UPS and a server. It also ensures a graceful unattended shutdown in the event
of an extended power failure.
USB Communications
Windows (98 and later) built-in power management functions provide monitoring of UPS status and manage the automatic orderly shutdown of the computer if a power outage ever exceeds the battery capacity of the UPS. Liebert MultiLink
Shutdown Software is provided.
SNMP Communication Option
Liebert IntelliSlot® IS-WEBRT3 Web Card provides SNMP and web-based management to your Liebert PSI. Provides SNMP MIB to monitor and control your UPS from your network management station or any PC running Microsoft Internet Explorer.
Network shutdown Sends both SNMP traps and emails for event notification,
and
automatically emails a daily UPS history. Auto-senses 10M/100M Ethernet Compatible with shutdown software to ensure
graceful computer shutdown
Liebert PSI-W Network Solution Package With Built-In Communications
Liebert PSI-W is the standard Liebert PSI made network–ready with a factory-installed Liebert IntelliSlot IS-WEBRT3 Web Card for SNMP communications. This totally integrated, cost-efficient solution allows remote monitoring, start-up or restart for connected equipment.
Optional Liebert MicroPOD Output Distribution And Maintenance Bypass Module
When your computer system can’t be without power, even for scheduled UPS maintenance, the Liebert MicroPOD Maintenance Bypass and Output Distribution Unit ensures continuous uptime. It allows you to manually transfer connected equipment to utility power via a maintenance bypass switch, permitting scheduled service or UPS replacement without the need to shut down connected equipment. Features include:
2U height minimizes rack
space requirements
Installs with plug-and-play ease
Two-year, no-hassle
replacement warranty
3
Page 4
Emerson Network Power.com
Emerson Network Power.
The global leader in enabling
Business-Critical Continuity
.
AC Power
Connectivity DC Power Embedded Computing Embedded Power Monitoring Outside Plant Power Switching & Controls Precision Cooling Racks & Integrated Cabinets Services Surge Protection
Liebert Corporation
1050 Dearborn Drive P.O. Box 29186 Columbus, Ohio 43229 800 877 9222 Phone (U.S. & Canada Only) 614 888 0246 Phone (Outside U.S.) 614 841 6022 FAX
Via Leonardo Da Vinci 8 Zona Industriale Tognana 35028 Piove Di Sacco (PD) Italy 39 049 9719 111 Phone 39 049 5841 257 FAX
Emerson Network Power Asia Pacific 29/F, The Orient Square Building F. Ortigas Jr. Road, Ortigas Center Pasig City 1605 Philippines +63 2 687 6615 +63 2 730 9572 FAX
liebert.com
24 x 7 Tech Support
800 222 5877 Phone 614 841 6755 (outside U.S.)
Liebert PSI XR Specifications
Model Number PS1000RT3-120 PS1500RT3-120 PS2200RT3-120 PS3000RT3-120 Network Solutions Package Number Power Rating, VA/W 1000VA/900W 1500VA/1350W 1920VA/1920W 3000VA/2700W
Dimensions, W x D x H, in (mm)
Unit 17.3 x 16.2 x 3.5
Shipping 22 x 24.1 x 9 (560 x 612 x 228) 22 x 24.1 x 9 (560 x 612 x 228) 22 x 34.8 x 9.0 (560 x 884 x 228) 22 x 34.8 x 9.0 (560 x 884 x 228)
Weight, lb (kg)
Unit 43 (20) 47 (21) 76 (35) 84 (38) Shipping 51 (23) 54 (25) 84 (38) 93 (42)
Input AC Parameters
Surge Protection 570J Voltage Range Without Battery
Operation Frequency Range 45~65Hz, (0.5Hz) Input Power Cord, 10ft (3m)
attached Output Receptacles (8) NEMA 5-15R (8) NEMA 5-15R (6) NEMA 5-15R (2) NEMA 5-20R
Voltage (Normal Mode) 110/120/127 VAC (configurable) Voltage (Battery Mode) 110/120/127 VAC; 5% before low-battery warning Transfer Time 4-6 ms typical Battery Waveform Sinewave
Battery Parameters
Typ e Valve-regulated, non-spillable, lead acid Recharge Time 5 hours to 90% of rated capacity, after full discharge into resistive load
Battery Backup Time
Full Load 4 min 3 min 3 min 3 min Half Load 12 min 9 min 11 min 9 min
Environmental
Operating Temperature, ˚F (˚C) 32 to 104 (0 to 40) Storage Temperature, ˚F (˚C) 5 to 104 (-15 to 40) Relative Humidity 0% to 90%, non-condensing Operating Altitude Up to 10,000 ft (3000m) at 95˚F (35˚C) without derating Audible Noise <40 dBA, internal fan(s) Off; <45 dBA, internal fan(s) On
Agency
Safety UL 1778, c-UL Listed Emissions FCC Part 15, Class A Network Surge UL 497 B Transportation ISTA Procedure 1A Certification
Rail Kit (included)
Rail Kit RAILKITPS3G-AEC
NEC limits the input current rating of the 2200VA model to 80% of the input plug’s rating. If 1920 or more is required, contact a certified electrician to change the input plug to 30A plug. Emerson Network Power assumes no liability for damage caused by miswiring or misapplication of the input plug.
PS1000RT3-120W PS1500RT3-120W PS2200RT3-120W PS3000RT3-120W
(440 x 412 x 88)
NEMA 5-15P plug NEMA 5-15P plug NEMA 5-20P plug NEMA L5-30P plug
17.3 x 16.2x 3.5
(440 x 412 x 88)
83 to 159 VAC (configurable)
17.3 x 25.9 x 3.5 (440 x 657x 88)
T-Slot, accepts 15A Plug
17.3 x 25.9 x 3.5 (440 x 657x 88)
(6) NEMA 5-15R (2) NEMA 5-20R
T-Slot, accepts 15A Plug
While every precaution has been taken to ensure accuracy and completeness in this literature, Liebert Corporation assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions.
© 2009 Liebert Corporation. All rights reserved throughout the world. Specifications subject to change without notice.
All names referred to are trademarks or registered trademarks of their respective owners.
® Liebert is a registered trademark of the Liebert Corporation.
SL-23318 (R09/09) Printed in USA
Business-Critical Continuity, Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. ©2009 Emerson Electric Co.
Loading...