This product is warranted against defects in workmanship and materials for one year from the date
o
f sale except for motors, which are warranted for two years. This warranty does not apply to
damage from accident, misuse, alteration, unauthorized repairs, unauthorized use, mishandling,
unreasonable use, abuse, including failure to perform reasonable maintenance, normal wear and
tear, nor where the connected voltage is more than 5% above the nameplate voltage, nor to the
equipment or products being improperly installed or wired or maintained in violation of this Owner's
M
anual. THIS WARRANTY DOES NOT APPLY TO FILTERS WHICH ARE CUSTOMER
REPLACEABLE PARTS. THIS PRODUCT IS NOT INTENDED FOR COMMERCIAL USE. THIS IS
THE SOLE AND EXCLUSIVE W ARRANTY GIVEN BY MANUFACTURER WITH RESPECT TO THE
PRODUCTS AND, TO THE MAXIMUM EXTENT PERMITTED BY LAW, IS IN LIEU OF AND
EXCLUDES ALL OTHER WARRANTIES AND CONDITIONS, EXPRESS OR IMPLIED, ARISING
B
Y OPERATION OF LAW OR OTHERWISE, INCLUDING WITHOUT LIMITATION,
MERCHANTABILITY AND/OR FITNESS FOR A PARTICULAR PURPOSE. No employee, agent,
dealer or other person is authorized to give any warranties or conditions on behalf of the
manufacturer . The customer shall be responsible for all costs incurred in the removal or reinstallation
and shipping of the product for repairs.
Within the limitations of this warranty, inoperative units should be returned, with a copy of the sales
receipt, freight prepaid to an authorized repair service center and the manufacturer will repair or
replace the product, at its option, at no charge to the customer with return freight paid by the
manufacturer . It is agreed that such repair or replacement is the exclusive remedy available from the
manufacturer and that TO THE MAXIMUM EXTENT PERMITTED BY LAW, THE MANUFACTURER
IS NOT RESPONSIBLE FOR DAMAGES OF ANY KIND, INCLUDING INCIDENTAL AND
CONSEQUENTIAL DAMAGE OR LOSS OF PR OFITS OR REVENUES. Some provinces and states
do not allow the exclusion or limitation of incidental or consequential damages, so the above
exclusion or limitation may not apply in some cases.
The warranty gives the customer specific legal rights, and the customer may also have other rights
which vary from province to province, or state to state.
SALES RECEIPT REQUIRED AS PROOF OF PURCHASE FOR WARRANTY CLAIMS.
GENERAL SAFETY INSTRUCTIONS
Safety Signal Words
DANGER: means if the safety information
is not followed someone
injured or killed.
WARNING:means if the safety
information is not followed someone
be seriously injured or killed.
CAUTION:means if the safety information
is not followed someone may be injured.
1. To reduce the risk of fire or shock
hazard, plug humidifier directly into a
120V, A.C. electr ical outlet. Do not use
extension cords.
2. Keep the electric cord out of traffic
areas.To reduce the risk of fire hazard,
never put the electric cord under rugs,
near heat registers, radiators, stov es or
heaters.
3. Always unplug the humidifier before
moving it, removing the fan assembly
section, before cleaning, or whenever
the humidifier is not in ser
4. Keep the humidifier clean.
will be ser iously
could
.
vice
5.Do not put foreign objects inside the
humidifier.
6.Do not allow to be used as a toy.
Close attention is necessary when
used by or near children.
7.Never use your humidifier while any
part is missing or damaged in any
manner.
8.To reduce the risk of electrical hazard
or damage to humidifier,do not tilt, jolt
or tip humidifier while unit is running.
o reduce the risk of damage to
T
9.
humidifier, unplug when not in use.
10. To reduce the risk of accidental
electr
ical shoc
k, do not touch the cord
or controls with wet hands.
11. Note the war ning label shown below.
WARNING: To reduce risk of fire,
electric shock, or injury always unplug
before servicing or cleaning.
2
Pivoting Lid
Bottles
Fan Assembly
Controls
Filter
Housing
Filters:
Replacement
Filter HDC12
Pivoting Lid Removed For Clarity
Casters
Humidistat
(On Power
Cord)
SP6647.qxd 7/5/06 8:23 AM Page 3
Know Y our Humidifier
DescriptionHD14070
Output/24 hrs14 Gallons/53 Litres
*
Capacity of Bottle2-3/8 Gallons/9 Litres
Sq. Ft. Coverage2900
*
Fan Speeds3
Auto Fan SpeedYes
Replacement FilterSet of 4 (HDC12)
Refill IndicatorYes
Auto Shut OffYes
Auto HumidistatYes
Controls
CastersYes (4)
UL ListedYes
Volts120 A.C.
tz60
Her
Amps 2.88
Watts165
* Based on an area with average insulation and an 8’
ceiling height ANSI/AHAM HU-1-1997. SEC. 8.1, results
may vary.
Electronic (Push Button)
3
H
umidified Air is Then
R
eleased Through the Top
Dry Air
Enters
Through
the Rear
SP6647.qxd 7/5/06 8:23 AM Page 4
How Y our Humidifier Works
Your new MoistAIR humidifier is designed
to satisfy home humidity requirements
through the principle of evaporation of
water into the air.
After water is added to the bottle, the
filters begin to soak up the water and
become totally saturated in approximately 30 minutes. Air is drawn in from
the rear of the humidifier and through the
filters by means of circulation fans.As air
passes through the filters, moisture is
absorbed into the air and then released
in the form of vapor. No water droplets
will enter the home. All evaporation into
the air takes place in the humidifier,
which means that the residue left by
evaporating water is not passed into the
home, but remains in the filter.
CAUTION: Use only EPA Registered
Bacteriostat. Under no circumstances
should you use water treatment
products designed for Roto belt or
Ultrasonic humidifiers.
CAUTION: To reduce the risk of
injury, fire or damage to humidifier,
use only cleaners specifically
recommended for humidifiers.Never
use flammable, combustible or
poisonous materials to clean your
humidifier.
To reduce the risk of scalds and
damage to humidifier, never put hot
water in humidifier.
Assembly
Your new MoistAIR humidifier is
completely assembled for you to use.
Remove the bag pack containing two
plastic caster pads from top of humidifier
and retain for future use if required. See
the following Step 1 for instr uctions.
Remove the packaging material from
inside your humidifier and follow the
instructions of this operator’s manual for
proper usage.The packaging material is
located under the fan assembly. Remove
the packaging material and discard.
4
Front of
Cabinet
NOTE: If positioning on
carpet, place caster pads
under front casters only
to level (if necessary).
Front
Caster
Caster Pad
Carpet
Surface
At Least 2" (5 cm) From Wall
SP6647.qxd 7/5/06 8:23 AM Page 5
Location Instructions
WARNING: For your own safety, do
not use humidifier if any parts are
damaged or missing.
Step 1:
Place humidifier on a flat level surface in
an area of your house where humidity is
needed most, or in an area which would
likely result in moist air being circulated
throughout the house, such as near a
cold air return.
Placing the unit level is ver y important if
the humidifier is located on carpeting.
NOTE: The humidifier contains water
bottles.The weight of the bottles in the
front of the cabinet may cause the front
casters to sink deeper into the carpet. If
this happens, the water level will be
higher towards the front of the humidifier,
and lower towards the back.The water
level float (located at the rear of the
cabinet) may not sense the water so the
flashing “F” will be displayed and the unit
will not energize. If this happens, the unit
will need to be leveled in order for the
humidifier to be energized.To level the
humidifier when located on carpet, place
the included caster pads under the front
two casters of the humidifier only.
NOTE: Due to release of cool, moist air
from humidifier, it is best to direct air
away from home thermostat and hot air
registers. It is best to position humidifier
next to an inside wall.Hot air registers
and cold air from outside walls can affect
the efficiencies of the controls. Unit
should not be placed where warm air
from a hot air register blows directly on
unit.
Moist air (humidity) produced will
disperse into the whole house, but area
closest to the unit will have the highest
humidity. If the unit is positioned close to
a window, condensation may form on the
window pane. If this is not appropriate
the unit should be repositioned in another
location.
Step 2:
The humidifier should be positioned
with the back (cord exit side), at least
5 centimeters away from the wall.
Air needs to enter through the louvers in
the rear panel in order for the humidifier
to operate at peak efficiency.
Operating Tips for Best Performance
1. Position the humidifier at least 2 inches
(5 cm) from any wall and away from
any heat registers.
Do not restr
2.
exiting the humidifier.
3. Use only EPA registered bacter iostat to
retard bacteria growth that may cause
odors and ma
health.
ict airflow from entering or
y be harmful to your
4. Perform regular cleaning as instructed
in “Cleaning and Maintenance” section
of this manual.
aporative wicking filters
Replace the e
5.
v
at least once per humidification
season or more depending on water
conditions in y
our area.
5
Fan Assembly
Pivoting
Lid
Bottles
Right
Bottle
Left
Bottle
Rear of
Humidifier
"Side-Fill Cap" Should
Always Face Rear
SP6647.qxd 7/5/06 8:23 AM Page 6
Electrical Hook-Up
Locate nearest 120V A.C. wall socket in
he location desired, preferably on inside
t
wall.With the humidifier in the desired
location, route the electrical cord safely
so no one will trip or upset the humidifier.
Plug in the electrical cord.
WARNING: To reduce the risk of fire
or shock hazard, humidifier should
be plugged into a 120V A.C. outlet.
Do not use extension cords.
To reduce the risk of electrical shock, this
humidifier has a polarized plug (one
blade is wider than the other).This plug
will fit in a polarized outlet only one way.
Water Fill
WARNING: To reduce the risk of
shock, always unplug humidifier
before cleaning or servicing.
f the plug does not fit fully in the outlet,
I
reverse plug.If it still does not fit, contact
a qualified electrician to install the proper
outlet. Do not change the plug in any way.
WARNING: To reduce the risk of fire
or shock hazard, do not pour or spill
water into control or motor area.
If controls get wet, let them dry
completely and have unit checked by
authorized service personnel before
plugging in.
This humidifier is designed for use with
the two water bottles that are located
under the pivoting lid.
Open the pivoting lid of the humidifier.
Remove the water bottles by lifting them
straight up and out of the cabinet.
Notice the water bottles are designed as
right and left hand units. Position them in
the correct location so the humidifier can
function properly. The water bottles
should rest in the front of the cabinet.
“Side-Fill Cap” must be facing the
Each
rear of the unit.
6
Loading...
+ 11 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.