Emerson Hd14060 Owner's Manual

Part No. SP6555 Printed in Canada
CAUTION: READ ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLATION.
SAVE THIS OWNER’S MANUAL FOR FUTURE REFERENCE.
Model No.
HD1406 Evaporative Console Humidifier Owner’s Manual
SP6555 Manual - 71236 7/12/05 2:21 PM Page 1
F
1/2
E
Safety Signal Words
DANGER: means if the safety information is
not followed someone will be seriously injured or killed. WARNING: means if the safety information is not followed someone could be seriously injured or killed. CAUTION: means if the safety information is not followed someone may be injured.
1. To reduce the risk of fire or shock hazard, plug humidifier directly into a 120V, A.C. electrical outlet. Do not use extension cords.
2. Keep the electric cord out of traffic areas. To reduce the risk of fire hazard, never put the electric cord under rugs, near heat registers, radiators, stoves or heaters.
3. Always unplug the humidifier before mov­ing it, removing the fan assembly section, before cleaning, or whenever the humidifi­er is not in service.
4. Keep the humidifier clean.
5. Do not put foreign objects inside the humidifier.
6. Never use your humidifier while any part is missing or damaged in any manner.
7. To reduce the risk of electrical hazard or damage to humidifier, do not tilt, jolt or tip humidifier over while unit is running.
8. To reduce the risk of damage to humidifi­er, unplug humidifier when water bottles are empty or when the humidifier is not in use.
9. To reduce the risk of accidental electrical shock, do not touch the cord or controls with wet hands.
10.Note the warning label shown below.
WARNING: To reduce the risk of fire, electric shock, or injury always unplug before filling, servicing or cleaning.
GENERAL SAFETY INSTRUCTIONS
2
Limited Warranty
All products covered by this Owner’s Manual are warranted against defects in workmanship and materials for one year from the date of sale except for motors, which are warranted for two years. This warranty does not apply to damage from accident, misuse or alteration nor where the connected voltage is more than 5% above the nameplate voltage, nor to the equipment improperly installed or wired or maintained in violation of this Owner’s Manual. No other written or oral warranty applies. No employee, agent, dealer or other person is authorized to give any warranties on behalf of Emerson. The customer shall be responsible for all costs incurred in the removal or reinstallation and shipping of the product for repairs. Within the limitations of this warranty, inoperative units should be returned, with a copy of the sales receipt, freight prepaid to a local repair service center and we will repair or replace, at our option, at no charge to you with return freight paid by Emerson. It is agreed that such repair or replacement is the exclusive remedy available from Emerson and that Emerson Is Not Responsible For Damages Of Any Kind, Including Incidental And Consequential Damage. Some states or provinces do not allow the exclusion or limitation of incidental or consequential damages, so the above exclusion or limitation may not apply to you. The warranty gives you specific legal rights, and you may also have other rights which vary from state to state or province to province.
Sales receipt required as proof of purchase for warranty claims.
SP6555 Manual - 71236 7/12/05 2:21 PM Page 2
3
Know Your Humidifier
F
E
1/2
Controls
Bottles
Fan Assembly
Filters:
Replacement
No. HDC-12
or HDC12C
Pivoting Lid
Removed for Clarity
Filter Housing
Description HD1406
* Gallon Output/24 hrs. 14 * Litre Output/24 hrs. 53
Capacity of Bottles (U.S. Gallons) 2-3/8 Gallons Each Capacity of Bottles (Litres) 9 Litres Each
* Sq. Ft. Coverage 2900
Fan Speeds 3 Filters 4 Pack (HDC-12) or (HDC12C) Manual Dryout Yes (see page 7) Fill Indicator Yes (Independent Bottle) Auto Shut Off Yes Auto Humidistat Yes Controls Rotary CUL Listed Yes Volts 120 A.C. Hertz 60 Amps 2.88 Watts 165
*Based on an area with average insulation and an 8 foot ceiling ANSI/AHAM HU-1-1997, SEC. 8.1
SP6555 Manual - 71236 7/12/05 2:21 PM Page 3
Humidifier Operations
Your new Emerson humidifier is designed to satisfy home humidity requirements through the principle of evaporation of water into the air.
After water is added to the bottles and posi­tioned in the humidifier, the filters begin to soak up the water and become totally saturat­ed in approximately 30 minutes. Air is drawn in from the rear of the humidifier and through the filters by means of two circulation fans. As air passes through the filters, moisture is absorbed into the air and then released through the top of the humidifier. This moist air is released in the form of vapor. No water droplets will enter the home. All evaporation into the air takes place in the humidifier, which means that the residue left by evaporating water is not passed into the home, but remains in the filter.
CAUTION: Use only liquid EPA Registered Bacteriostat available from your local retail store. Under no circum­stances should you use water treatment products for Roto belt or Ultrasonic humidifiers.
inside your humidifier and follow the instruc­tions of this owner’s manual for proper usage. The packaging material is located under the fan assembly. Remove the pack­aging material and discard.
Humidified Air is
Then Released
Through the Top
Dry Air Enters Through the Rear
CAUTION: Keep your humidifier clean. While humidifiers do not cause colds, some studies suggest that dirty humidi­fiers can cause cold-like symptoms in some people. To avoid this, clean your humidifier weekly with cleaners specifi­cally recommended for evaporative humidifiers.
Unpacking & Assembly
Your new Emerson humidifier is completely assembled for you to use. Remove the bag pack containing two plastic caster pads from top of humidifier and retain for future use if required. See Step 1 on page 5 for instruc­tions. Remove the packaging material from
Electrical Hook-Up
Locate nearest 120V A.C. wall socket in the location desired, preferably on inside wall. With the humidifier in the desired location, route the electrical cord safely so no one will trip or upset the humidifier. Plug in the electrical cord.
WARNING: To reduce the risk of fire or shock hazard, humidifier should be plugged into a 120V A.C. outlet. Do not use extension cords.
To reduce the risk of electrical shock, this humidifier has a polarized plug (one blade is wider than the other). This plug will fit in a polarized outlet only one way.
If the plug does not fit fully in the outlet, reverse plug. If it still does not fit, contact a qualified electrician to install the proper outlet. Do not change the plug in any way.
4
SP6555 Manual - 71236 7/12/05 2:21 PM Page 4
5
WARNING: For your own safety, do not use humidifier if any parts are damaged or missing.
Step 1
Place humidifier on a flat level surface in area of house where humidity is needed most, or one which would likely result in moist air being circulated throughout the house such as near a cold air return. Placing the unit level is very important if the humidifier is located on carpeting.
NOTE: This console humidifier contains water bottles. The weight of the bottles in the front of the cabinet may sink the front casters deeper in the carpet. This will keep the water level forward in the cabi­net. The water level float (located at the rear of the cabinet) may not sense the water and the fill light will be on and the unit will not energize. If this happens, the unit will need to be leveled in order for the humidifier to be energized.
To level the humidifier on carpeted surfaces place the included caster pads under the front two casters of the humidifier only. Moist air (humidity) produced will disperse into the whole house, but area closest to unit will have the highest humidity. If the unit is positioned close to a window, condensation may form on the window pane. If this is not appropriate the unit should be repositioned in another location.
Location Instructions
Water Fill
WARNING: To reduce the risk of shock, always unplug humidifier before filling, cleaning, or servicing.
WARNING: To reduce the risk of fire or shock hazard, do not pour or spill water into control or motor area. Close the control cover. If controls get wet, let them dry completely and have unit checked by authorized service person­nel before plugging in.
This humidifier is designed to be used with the two water bottles that are located under the pivoting lid.
NOTE: Due to release of cool, moist air from humidifier, it is best to direct air away from home thermostat and hot air registers. It is best to position humidifier next to an inside wall. Hot air registers and cold air from out­side walls can affect the efficiencies of the controls. Unit should not be placed where warm air from a hot air register blows directly on unit.
Step 2
The humidifier should be positioned with the back (cord exit side), at least 2 inches away from the wall. Air needs to enter through lou­vers in the back of the cabinet in order for the humidifier to operate at peak efficiency.
Water Bottles
Cabinet
Front of Humidifier
Fan Assembly
NOTE: If positioning on carpet, place
caster pads under front casters only
to level (if necessary).
Front of Cabinet
Front Caster
Caster Pad
Carpet Surface
At Least 2" From Wall
F
E
1/2
Pivoting Lid Removed for Clarity
SP6555 Manual - 71236 7/12/05 2:21 PM Page 5