Emerson Fisher MR95 Series, Fisher MR95L, Fisher MR95H, Fisher MR95HT, Fisher MR95HD Installation Manual

...
Page 1
Installation Guide D103587X014
July 2017
MR95 Series
Introduction
This Installation Guide provides instructions for installation, startup and adjustment. To receive a copy of the Instruction Manual, contact your local Sales Office or view a copy at www.fisher.com. For further information refer to MR95 Series Instruction Manual, D103587X012.
PED Category
This product may be used as a safety accessory with pressure equipment in the following Pressure Equipment Directive. It may also be used outside of the Pressure Equipment Directive using Sound Engineering Practice (SEP) per table below. For information on the current PED revision see Bulletin: D103053X012.
TYPE PRODUCT SIZE BODY MATERIAL CATEGORY
MR95L/
MR95LD
MR95H/
MR95HD
MR95HP/ MR95HT/
MR95HDP
1/4 NPT, DN 15 to 25 /
1/2 to 1 in.
1/4 NPT, DN 15 to 25 /
1/2 to 1 in.
DN 40 and 50 /
1-1/2 and 2 in.
1/4 NPT, DN 15 to 25 /
1/2 to 1 in.
DN 40 and 50 /
1-1/2 and 2 in.
All SEP
All SEP
Cast iron I
Steel and
Stainless steel
All SEP
Steel and
Stainless steel
II
II
Specications
Available Constructions
Type MR95L: Pressure reducing regulator for outlet pressures from 0.14 to 2.1 bar / 2 to 30 psig. 1/4 to 1 in. body sizes only.
Type MR95H: Pressure reducing regulator for outlet pressures from 0.34 to 10.3 bar / 5 to 150 psig.
Type MR95HP: Pressure reducing regulator for outlet pressures from 1.0 to 27.6 bar / 15 to 400 psig (soft-seated).
Type MR95HT: High temperature pressure reducing regulator for outlet pressures from 1.0 to 20.7 bar / 15 to 300 psig (metal seat) and up to 343°C / 650°F.
Type MR95LD: Pressure reducing differential regulator for differential set pressures from 0.14 to 2.1 bar / 2 to 30 psi with maximum inlet pressure up to 20.7 bar / 300 psi and maximum outlet pressure up to 8.6 bar / 125 psi. 1/4 to 1 in. body sizes only.
Type MR95HD: Pressure reducing differential regulator for differential set pressures from 0.34 to 10.3 bar / 5 to 150 psi with maximum inlet/outlet pressures up to 20.7 bar / 300 psig.
Type MR95HDP: Pressure reducing differential regulator for differential set pressures from 0.34 to 10.3 bar / 5 to 150 psi with maximum inlet/outlet pressures up to 41.4 bar / 600 psi.
Body and Orifice Sizes
1/4 NPT body: 7.22 mm / 0.284 in. orifice
DN 15 / 1/2 in. body: 10.56 mm / 0.416 in. orifice
DN 20 and 25 / 3/4 and 1 in. bodies: 16.02 mm / 0.631 in. orifice
DN 40 and 50 / 1-1/2 and 2 in. bodies (not available for Types MR95L and MR95LD): 29 mm / 1.142 in. orifice
End Connection Styles
NPT, SWE, Welded and Integral CL150 RF, CL300 RF, CL600 RF and PN 16/25/40 RF; all sizes are fabricated with slip-on flanges (for welded end connections) and are EN flanged 356 mm face-to-face (14 in. face-to-face)
Outlet and Differential Pressure Ranges
(1)
See Table 1
Maximum Spring Case Loading Pressure for Types MR95LD, MR95HD and MR95HDP
See Table 2
Maximum Cold Working Pressures of Body Size and Materials
(1)(2)
See Table 2
Pressure Registration
Internal or External
Maximum Temperature Ranges of Diaphragm and Seat Materials
(1)(2)
See Table 3
Shutoff Classification Per ANSI/FCI 70-3-2004
Metal Seats: Class IV
PTFE: Class IV
Elastomer Seats: Class VI or better
API 614 Compliant
Steel or Stainless steel constructions with Stainless steel trim meet API 614 Requirements.
Sour Gas Service Capability
Optional materials are available for applications handling sour gases. These constructions comply with the recommendations of NACE International Standards MR0175-2002 and MR0103. Optional materials are available to meet ANSI/NACE MR0175/ISO 15156.
Installation
WARNING
!
Only qualified personnel shall install or service a regulator. Regulators should be installed,
operated and maintained in accordance with
international and applicable codes and regulations and Emerson Process Management Regulator Technologies, Inc. instructions.
If the regulator vents fluid or a leak develops in the system, it indicates that service is required. Failure to take the regulator out of service immediately may create a hazardous condition.
Personal injury, equipment damage or leakage due to escaping fluid or bursting of pressure containing parts may result if this regulator is overpressured or is installed where service conditions could exceed the limits given in the Specifications section or where conditions exceed any ratings of the adjacent piping or piping connections.
1. The pressure/temperature limits in this Installation Guide and any applicable standard or code limitation should not be exceeded.
2. The pressure limits given are based on the body size and body materials only. Actual pressure limits of the assembled regulator may decrease and vary depending on the temperature, body end connection, diaphragm, seat and/or trim material of the regulator.
Page 2
MR95 Series
Table 1. Outlet and Differential Pressure Ranges
TYPE
DN In. bar psi/psig
BODY SIZE OUTLET OR DIFFERENTIAL PRESSURE RANGE
0.14 to 0.41 2 to 6
MR95L and MR95LD 15, 20 and 25 1/4 NPT, 1/2, 3/4 and 1
0.34 to 1.0 5 to 15
0.90 to 2.1 13 to 30
1.0 to 2.1 15 to 30
15, 20 and 25 1/4 NPT, 1/2, 3/4 and 1
1.7 to 5.2 25 to 75
4.8 to 10.3 70 to 150
0.34 to 5.5 5 to 80
MR95H, MR95HD and MR95HDP
40 and 50 1-1/2 and 2
4.1 to 8.3 60 to 120
6.9 to 9.7 100 to 140
8.3 to 10.3 120 to 150
0.34 to 4.1 5 to 60
3.4 to 8.3 50 to 120
MR95HT
15, 20 and 25 1/4 NPT, 1/2, 3/4 and 1
40 and 50 1-1/2 and 2
15, 20 and 25 1/4 NPT, 1/2, 3/4 and 1
MR95HP
40 and 50 1-1/2 and 2
1. For Types MR95LD, MR95HD and MR95HDP regulators, the pressure ranges indicate the differential pressure that can be obtained with the indicated spring. The differential pressure (spring setting) is added to the spring case loading pressure to determine the actual outlet pressure.
Table 2. Maximum Cold Working Pressures of Body Size and Material
MAXIMUM INLET
TYPE BODY SIZE BODY MATERIALS
MR95L/
MR95LD
MR95H/
MR95HD
MR95HDP All available sizes
MR95HP All available sizes
MR95HT
1. The pressure/temperature limits in this Installation Guide and any applicable standard or code limitation should not be exceeded.
2. The pressure limits given are based on the body size and body materials only. Actual pressure limits of the assembled regulator may decrease and vary depending on the temperature, body end connection, diaphragm, seat and/or trim material of the regulator.
3. Not available for 1/4 NPT body size.
All available sizes
All available sizes
1/4 NPT and DN 15 to 25 /
1/2 to 1 in.
DN 40 and 50 /
1-1/2 and 2 in.
WCC/LCC Steel; CF8M/CF3M Stainless Steel;
WCC/LCC Steel; CF8M/CF3M Stainless Steel;
Monel
CF8M/CF3M Stainless Steel; Monel
CF8M/CF3M Stainless Steel; Monel
CF8M/CF3M Stainless Steel; Monel
WCC/LCC Steel; CF8M/CF3M Stainless Steel;
Monel
Gray Cast Iron 17.2 250 3.4 50 3.4 50
Monel
®(3)
; Hastelloy® C
(3)
Gray Cast Iron 17.2 250 17.2 250 17.2 250
®(3)
; Hastelloy® C
Hastelloy® C
Hastelloy® C
Hastelloy® C
®
; Hastelloy® C; Aluminum-Bronze
(3)
; Aluminum-Bronze
WCC/LCC Steel 41.4 600 41.4 600 41.4 600
(3)
; Aluminum-Bronze
WCC/LCC Steel 68.9 1000 41.4 600 41.4 600
(3)
; Aluminum-Bronze
WCC/LCC Steel 41.4 600 41.4 600 41.4 600
(3)
; Aluminum-Bronze
(3)
®(3)
;
(3)
®(3)
;
(3)
®(3)
;
(3)
PRESSURE
bar psig bar psig bar psig
20.7 300 8.6 125 8.6 125
20.7 300 20.7 300 20.7 300
41.4 600 37.9 550 37.9 550
68.9 1000 37.9 550 37.9 550
41.4 600 37.9 550 37.9 550
41.4 600 31.0 450 31.0 450
Table 3. MR95 Series Temperature Capabilities
TRIM MATERIAL SEAT DIAPHRAGM O-RING
Nitrile (NBR)
Neoprene (CR)
Fluorocarbon (FKM)
(3)
Ethylenepropylene (EPDM)
Peruoroelastomer (FFKM)
PTFE
Metal
     
Composition
Graphite
DIAPHRAGM PROTECTOR
GASKET
1.0 to 6.9 15 to 100
5.5 to 20.7 80 to 300
1.0 to 6.9 15 to 100
4.1 to 17.9 60 to 260
1.0 to 6.9 15 to 100
5.5 to 27.6 80 to 400
1.0 to 6.9 15 to 100
4.1 to 20.7 60 to 300
(1)(2)
MAXIMUM OUTLET
(1)(2)
PRESSURE
MAXIMUM SPRING
CASE PRESSURE
TEMPERATURE
°C °F
-40 to 82 -40 to 180
-40 to 82 -40 to 180
-18 to 149,
Limited to 93°C for hot water
Limited to 200°F for hot water
-7 to 135 20 to 275
-18 to 218 0 to 425
-40 to 204 -40 to 400
-40 to 343 -40 to 650
-40 to 204,
Limited to 149°C for steam
Limited to 300°F for steam
-40 to 343 -40 to 650
(1)
0 to 300,
-40 to 400,
BODY MATERIAL
Stainless steel
Gray cast iron -29 to 208 -20 to 406
WCC Steel
(4)
(4)
LCC Steel
(4)
, Monel® or Hastelloy® C -40 to 288 -40 to 550
-29 to 343 -20 to 650
-40 to 343 -40 to 650
TEMPERATURE
°C °F
Aluminum-Bronze -40 to 260 -40 to 500
1. The pressure/temperature limits in this Installation Guide and any applicable standard limitation should not be exceeded.
2. The temperature limits given are based on the body size and body materials only. Actual temperature limits of the assembled regulator may decrease and vary depending on the body end connection, diaphragm, seat and/or trim material of the regulator.
3. Not for use on steam service.
4. Meets API 614 requirements (with Stainless steel trim).
®
Monel
is a mark owned by Special Metals Corporation.
Hastelloy® C is a mark owned by Haynes International, Inc.
2
Page 3
MR95 Series
To avoid such injury or damage, provide pressure-relieving or pressure-limiting devices (as required by the appropriate code, regulation or standard) to prevent service conditions from exceeding limits.
Additionally, physical damage to the regulator could result in personal injury and property damage due to escaping fluid. To avoid such injury and damage, install the regulator in a safe location.
Clean out all pipelines before installation of the regulator and check to be sure the regulator has not been damaged or has collected foreign material during shipping. For NPT bodies, apply pipe compound to the external pipe threads. For flanged bodies, use suitable line gaskets and approved piping and bolting practices. Install the regulator in any position desired, unless otherwise specified, but be sure flow through the body is in the direction indicated by the arrow on the body.
Note
It is important that the regulator be installed so that the vent hole in the spring case is unobstructed at all times. For outdoor installations, the regulator should be located away from vehicular traffic and positioned so that water, ice and other foreign materials cannot enter the spring case through the vent. Avoid placing the regulator beneath eaves or downspouts and be sure it is above the probable snow level.
Overpressure Protection
The recommended pressure limitations are stamped on the regulator nameplate. Some type of overpressure protection is needed if the actual inlet pressure exceeds the maximum operating outlet pressure rating. Overpressure protection should also be provided if the regulator inlet pressure is greater than the safe working pressure of the downstream equipment.
Regulator operation below the maximum pressure limitations does not preclude the possibility of damage from external sources or debris in the line. The regulator should be inspected for damage after any overpressure condition.
Startup
The regulator is factory set at approximately the midpoint of the spring range or the pressure requested, so an initial adjustment may be required to give the desired results. With proper installation completed and relief valves properly adjusted, slowly open the upstream and downstream shutoff valves.
Adjustment
To change the outlet pressure, loosen the jam nut and turn the adjusting screw clockwise to increase outlet pressure or counterclockwise to decrease it. Monitor the outlet pressure with a test gauge during the adjustment. Tighten the jam nut to maintain the desired setting.
Taking Out of Service (Shutdown)
WARNING
!
To avoid personal injury resulting from sudden release of pressure, isolate the regulator from all pressure before attempting disassembly.
Parts List
Key Description
1 Body 2 Spring Case 3* Orifice 4* Valve Plug, Metal seat 4* Disk Holder Assembly, Composition seat 4a Disk Holder 4b Disk 4c O-ring, Type MR95HP only (not shown) 5 Valve Plug Guide 6 Stem/Stem Assembly 6a Stem 6b Pusher Plate 6b O-ring 6c O-ring 7 Stem Guide Bushing 8 Lower Spring Seat 9 Upper Spring Seat 10 Pusher Post, (not shown) 11 Control Spring 12* Diaphragm 13 Nameplate 14* Diaphragm Protector (not shown) 15 Adjusting Screw 16 Cap Screw 17 Jam Nut 18 Nameplate Drive Screw 19* Diaphragm Gasket 20 Pitot Tube (for constructions without control line) 21 Diaphragm Head Assembly,Types MR95L and MR95LD only
(not shown) 21a Diaphragm Head 21b Lower Spring Seat 21c Screw 21 Diaphragm Head (not shown) 22 Adjusting Screw Assembly (Tee Handle Adjustment) 23 Handwheel (not shown) 26 Inner Valve Spring 27 Inner Valve Base (not shown) 27 Inner Valve Base Assembly, Type MR95HP only (not shown) 29* Gasket (not shown) 31 Locknut (not shown) 32 Stuffing Box 33 Adjusting Screw 34 Packing Follower 35 Stuffing Box Nut 36 Packing 37* Stuff Box Gasket 38 Handwheel/Handle 39 Internal Adaptor 40 External Adaptor 41 Machine Screw 41 Jam Nut, Types MR95HD and MR95HDP only 42 Spring 43 Washer 44 Washer 45* O-ring, Types MR95HD and MR95HDP only (not shown) 47 NACE Tag (not shown) 48 Tag Wire (not shown) 49 Lockwasher (not shown) 50* Sealing Washer 51 Vent, Type Y602-12 (not shown) 52 Plug 62 Adaptor, Types MR95L and MR95LD only (not shown) 63* Bottom Plug Seal 64 Flow Arrow 65 Pipe Plug (not shown) 66 Inlet Pressure Gauge (not shown) 67 Outlet Pressure Gauge (not shown) 69 ATEX Tag (not shown) 70 PED Tag (not shown)
*Recommended Spare Part
1. Only one metal diaphragm is needed for Types MR95L and MR95LD with 1/4 NPT body
size and 0.14 to 0.41 bar / 2 to 6 psi spring range.
(1)
3
Page 4
MR95 Series
50
L2
L2
OR
L1
L4
15
2
11
21B
(2)
16
7
4
26
(3)
63
13
6
18
17
9 L2
21C
21A
3
5
SEALED ADJUSTING
SCREW OPTION
T
12
TEE-HANDLE OPTION
1
20
L2
L2
COMPOSITE SEAT OPTION
6B
52
6C
22
4B
4A
L1
L2
L2
L3 36
43
L1
11
L2
7
L1
OR
L4
6A
CONTROL LINE OPTION
12
64
GF04915
APPLY LUBRICANT OR SEALANT T = THREAD LOCKER L1 = GENERAL PURPOSE PTFE OR LITHIUM GREASE L2 = ANTI-SEIZE COMPOUND L4 = GRAPHITE SEALANT
1. Lubricants and sealants must be selected such that they meet the temperature requirements.
2. Apply L2 (anti-seize compound) on key 16 for Stainless steel bolts.
3. Apply L4 (graphite sealant) instead of L1 (general purpose PTFE or lithium grease) on key 63 for graphite ring.
18
METAL DIAPHRAGM OPTION
(1)
:
19
GF04918
41
33
44
38
34
35
32
37
42
2
(2)
16
39
40
9
L2
8
12
1
4
26
(3)
63
4B
4A
20
METAL DIAPHRAGM OPTION
6
L2
3
L2
5
6B
6A
CONTROL LINE OPTIONCOMPOSITION SEAT OPTION
APPLY LUBRICANT
L1 = GENERAL PURPOSE PTFE OR LITHIUM GREASE
L2 = ANTI-SEIZE COMPOUND L4 = GRAPHITE SEALANT
(1)
:
19
12
52
L1
6C
Figure 1. Type MR95L, 1/4 NPT and DN 15 to 25 /
1/2 to 1 In. Body Sizes Assembly
Webadmin.Regulators@emerson.com
Fisher.com
Emerson Automation Solutions
Americas McKinney, Texas 75070 USA T +1 800 558 5853
+1 972 548 3574
Europe Bologna 40013, Italy T +39 051 419 0611
For further information on the current PED revision see Bulletin: D103053X012 or scan the QR code.
The distinctive diamond shape cast into every spring case uniquely identifies the regulator as part of the Fisher™ brand and assures you of the highest-quality engineering, durability, performance, and support.
Facebook.com/EmersonAutomationSolutions
LinkedIn.com/company/emerson-automation-solutions
Twitter.com/emr_automation
Asia Pacic
Singapore 128461, Singapore T +65 6777 8211
Middle East and Africa
Dubai, United Arab Emirates T +971 4 811 8100
Figure 2. Types MR95HD and MR95HDP,
1/4 NPT and DN 15 to 50 / 1/2 to 2 In. Body Sizes Assembly
D103587X014 © 2014, 2019 Emerson Process Management Regulator Technologies, Inc. All rights reserved. 01/19. The Emerson logo is a trademark and service mark of Emerson Electric Co. All other marks are the property of their prospective owners. Fisher™ is a mark owned by Fisher Controls International LLC, a business of Emerson Automation Solutions.
The contents of this publication are presented for information purposes only, and while effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available on request. We reserve the right to modify or improve the
designs or specications of our products at any time without notice.
Emerson Process Management Regulator Technologies, Inc does not assume responsibility for the selection, use or maintenance of any product. Responsibility for proper selection, use and maintenance of any Emerson Process Management Regulator Technologies, Inc. product remains solely with the purchaser.
Loading...