This Installation Guide provides instructions for installation, startup
and adjustment. To receive a copy of the Instruction Manual, contact
your local Sales Office or view a copy at www.fisher.com. For further
information refer to MR95 Series Instruction Manual, D103587X012.
PED Category
This product may be used as a safety accessory with pressure
equipment in the following Pressure Equipment Directive. It may
also be used outside of the Pressure Equipment Directive using
Sound Engineering Practice (SEP) per table below. For information
on the current PED revision see Bulletin: D103053X012.
TYPEPRODUCT SIZEBODY MATERIALCATEGORY
MR95L/
MR95LD
MR95H/
MR95HD
MR95HP/
MR95HT/
MR95HDP
1/4 NPT, DN 15 to 25 /
1/2 to 1 in.
1/4 NPT, DN 15 to 25 /
1/2 to 1 in.
DN 40 and 50 /
1-1/2 and 2 in.
1/4 NPT, DN 15 to 25 /
1/2 to 1 in.
DN 40 and 50 /
1-1/2 and 2 in.
AllSEP
AllSEP
Cast ironI
Steel and
Stainless steel
AllSEP
Steel and
Stainless steel
II
II
Specications
Available Constructions
Type MR95L: Pressure reducing regulator for outlet pressures
from 0.14 to 2.1 bar / 2 to 30 psig. 1/4 to 1 in. body sizes only.
Type MR95H: Pressure reducing regulator for outlet pressures
from 0.34 to 10.3 bar / 5 to 150 psig.
Type MR95HP: Pressure reducing regulator for outlet
pressures from 1.0 to 27.6 bar / 15 to 400 psig (soft-seated).
Type MR95HT: High temperature pressure reducing regulator
for outlet pressures from 1.0 to 20.7 bar / 15 to 300 psig
(metal seat) and up to 343°C / 650°F.
Type MR95LD: Pressure reducing differential regulator for
differential set pressures from 0.14 to 2.1 bar / 2 to 30 psi with
maximum inlet pressure up to 20.7 bar / 300 psi and maximum
outlet pressure up to 8.6 bar / 125 psi. 1/4 to 1 in. body
sizes only.
Type MR95HD: Pressure reducing differential regulator for
differential set pressures from 0.34 to 10.3 bar / 5 to 150 psi
with maximum inlet/outlet pressures up to 20.7 bar / 300 psig.
Type MR95HDP: Pressure reducing differential regulator for
differential set pressures from 0.34 to 10.3 bar / 5 to 150 psi
with maximum inlet/outlet pressures up to 41.4 bar / 600 psi.
Body and Orifice Sizes
1/4 NPT body: 7.22 mm / 0.284 in. orifice
DN 15 / 1/2 in. body: 10.56 mm / 0.416 in. orifice
DN 20 and 25 / 3/4 and 1 in. bodies: 16.02 mm / 0.631 in. orifice
DN 40 and 50 / 1-1/2 and 2 in. bodies (not available for
Types MR95L and MR95LD): 29 mm / 1.142 in. orifice
End Connection Styles
NPT, SWE, Welded and Integral CL150 RF, CL300 RF,
CL600 RF and PN 16/25/40 RF; all sizes are fabricated with
slip-on flanges (for welded end connections) and are EN
flanged 356 mm face-to-face (14 in. face-to-face)
Outlet and Differential Pressure Ranges
(1)
See Table 1
Maximum Spring Case Loading Pressure for
Types MR95LD, MR95HD and MR95HDP
See Table 2
Maximum Cold Working Pressures of
Body Size and Materials
(1)(2)
See Table 2
Pressure Registration
Internal or External
Maximum Temperature Ranges of
Diaphragm and Seat Materials
(1)(2)
See Table 3
Shutoff Classification Per ANSI/FCI 70-3-2004
Metal Seats: Class IV
PTFE: Class IV
Elastomer Seats: Class VI or better
API 614 Compliant
Steel or Stainless steel constructions with Stainless steel trim
meet API 614 Requirements.
Sour Gas Service Capability
Optional materials are available for applications handling sour
gases. These constructions comply with the recommendations
of NACE International Standards MR0175-2002 and MR0103.
Optional materials are available to meet ANSI/NACE
MR0175/ISO 15156.
Installation
WARNING
!
Only qualified personnel shall install or service
a regulator. Regulators should be installed,
operated and maintained in accordance with
international and applicable codes and regulations
and Emerson Process Management Regulator
Technologies, Inc. instructions.
If the regulator vents fluid or a leak develops in the
system, it indicates that service is required. Failure
to take the regulator out of service immediately
may create a hazardous condition.
Personal injury, equipment damage or leakage
due to escaping fluid or bursting of pressure
containing parts may result if this regulator
is overpressured or is installed where service
conditions could exceed the limits given in
the Specifications section or where conditions
exceed any ratings of the adjacent piping or
piping connections.
1. The pressure/temperature limits in this Installation Guide and any applicable standard or code limitation should not be exceeded.
2. The pressure limits given are based on the body size and body materials only. Actual pressure limits of the assembled regulator may decrease
and vary depending on the temperature, body end connection, diaphragm, seat and/or trim material of the regulator.
Page 2
MR95 Series
Table 1. Outlet and Differential Pressure Ranges
TYPE
DNIn.barpsi/psig
BODY SIZEOUTLET OR DIFFERENTIAL PRESSURE RANGE
0.14 to 0.412 to 6
MR95L and MR95LD15, 20 and 251/4 NPT, 1/2, 3/4 and 1
0.34 to 1.05 to 15
0.90 to 2.113 to 30
1.0 to 2.115 to 30
15, 20 and 251/4 NPT, 1/2, 3/4 and 1
1.7 to 5.2 25 to 75
4.8 to 10.370 to 150
0.34 to 5.55 to 80
MR95H, MR95HD and MR95HDP
40 and 501-1/2 and 2
4.1 to 8.360 to 120
6.9 to 9.7100 to 140
8.3 to 10.3120 to 150
0.34 to 4.15 to 60
3.4 to 8.350 to 120
MR95HT
15, 20 and 251/4 NPT, 1/2, 3/4 and 1
40 and 501-1/2 and 2
15, 20 and 251/4 NPT, 1/2, 3/4 and 1
MR95HP
40 and 501-1/2 and 2
1. For Types MR95LD, MR95HD and MR95HDP regulators, the pressure ranges indicate the differential pressure that can be obtained with the indicated spring. The differential pressure (spring
setting) is added to the spring case loading pressure to determine the actual outlet pressure.
Table 2. Maximum Cold Working Pressures of Body Size and Material
MAXIMUM INLET
TYPEBODY SIZEBODY MATERIALS
MR95L/
MR95LD
MR95H/
MR95HD
MR95HDPAll available sizes
MR95HPAll available sizes
MR95HT
1. The pressure/temperature limits in this Installation Guide and any applicable standard or code limitation should not be exceeded.
2. The pressure limits given are based on the body size and body materials only. Actual pressure limits of the assembled regulator may decrease and vary depending on the temperature, body
end connection, diaphragm, seat and/or trim material of the regulator.
3. Not available for 1/4 NPT body size.
All available sizes
All available sizes
1/4 NPT and DN 15 to 25 /
1/2 to 1 in.
DN 40 and 50 /
1-1/2 and 2 in.
WCC/LCC Steel; CF8M/CF3M Stainless Steel;
WCC/LCC Steel; CF8M/CF3M Stainless Steel;
Monel
CF8M/CF3M Stainless Steel; Monel
CF8M/CF3M Stainless Steel; Monel
CF8M/CF3M Stainless Steel; Monel
WCC/LCC Steel; CF8M/CF3M Stainless Steel;
Monel
Gray Cast Iron17.22503.4503.450
Monel
®(3)
; Hastelloy® C
(3)
Gray Cast Iron17.225017.225017.2250
®(3)
; Hastelloy® C
Hastelloy® C
Hastelloy® C
Hastelloy® C
®
; Hastelloy® C; Aluminum-Bronze
(3)
; Aluminum-Bronze
WCC/LCC Steel41.460041.460041.4600
(3)
; Aluminum-Bronze
WCC/LCC Steel68.9100041.460041.4600
(3)
; Aluminum-Bronze
WCC/LCC Steel41.460041.460041.4600
(3)
; Aluminum-Bronze
(3)
®(3)
;
(3)
®(3)
;
(3)
®(3)
;
(3)
PRESSURE
barpsigbarpsigbarpsig
20.73008.61258.6125
20.730020.730020.7300
41.460037.955037.9550
68.9100037.955037.9550
41.460037.955037.9550
41.460031.045031.0450
Table 3. MR95 Series Temperature Capabilities
TRIM MATERIALSEATDIAPHRAGMO-RING
Nitrile (NBR)
Neoprene (CR)
Fluorocarbon (FKM)
(3)
Ethylenepropylene (EPDM)
Peruoroelastomer (FFKM)
PTFE
Metal
Composition
Graphite
DIAPHRAGM
PROTECTOR
GASKET
1.0 to 6.915 to 100
5.5 to 20.780 to 300
1.0 to 6.915 to 100
4.1 to 17.960 to 260
1.0 to 6.915 to 100
5.5 to 27.680 to 400
1.0 to 6.915 to 100
4.1 to 20.760 to 300
(1)(2)
MAXIMUM OUTLET
(1)(2)
PRESSURE
MAXIMUM SPRING
CASE PRESSURE
TEMPERATURE
°C°F
-40 to 82-40 to 180
-40 to 82-40 to 180
-18 to 149,
Limited to 93°C for hot water
Limited to 200°F for hot water
-7 to 13520 to 275
-18 to 2180 to 425
-40 to 204-40 to 400
-40 to 343-40 to 650
-40 to 204,
Limited to 149°C for steam
Limited to 300°F for steam
-40 to 343-40 to 650
(1)
0 to 300,
-40 to 400,
BODY MATERIAL
Stainless steel
Gray cast iron -29 to 208-20 to 406
WCC Steel
(4)
(4)
LCC Steel
(4)
, Monel® or Hastelloy® C-40 to 288-40 to 550
-29 to 343-20 to 650
-40 to 343-40 to 650
TEMPERATURE
°C°F
Aluminum-Bronze-40 to 260-40 to 500
1. The pressure/temperature limits in this Installation Guide and any applicable standard limitation should not be exceeded.
2. The temperature limits given are based on the body size and body materials only. Actual temperature limits of the assembled regulator may decrease and vary depending on the body end
connection, diaphragm, seat and/or trim material of the regulator.
3. Not for use on steam service.
4. Meets API 614 requirements (with Stainless steel trim).
®
Monel
is a mark owned by Special Metals Corporation.
Hastelloy® C is a mark owned by Haynes International, Inc.
2
Page 3
MR95 Series
To avoid such injury or damage, provide
pressure-relieving or pressure-limiting devices
(as required by the appropriate code, regulation
or standard) to prevent service conditions from
exceeding limits.
Additionally, physical damage to the regulator
could result in personal injury and property
damage due to escaping fluid. To avoid such
injury and damage, install the regulator in a
safe location.
Clean out all pipelines before installation of the regulator and check
to be sure the regulator has not been damaged or has collected
foreign material during shipping. For NPT bodies, apply pipe
compound to the external pipe threads. For flanged bodies, use
suitable line gaskets and approved piping and bolting practices.
Install the regulator in any position desired, unless otherwise
specified, but be sure flow through the body is in the direction
indicated by the arrow on the body.
Note
It is important that the regulator be installed
so that the vent hole in the spring case
is unobstructed at all times. For outdoor
installations, the regulator should be located away
from vehicular traffic and positioned so that water,
ice and other foreign materials cannot enter the
spring case through the vent. Avoid placing the
regulator beneath eaves or downspouts and be
sure it is above the probable snow level.
Overpressure Protection
The recommended pressure limitations are stamped on the
regulator nameplate. Some type of overpressure protection is
needed if the actual inlet pressure exceeds the maximum operating
outlet pressure rating. Overpressure protection should also be
provided if the regulator inlet pressure is greater than the safe
working pressure of the downstream equipment.
Regulator operation below the maximum pressure limitations does
not preclude the possibility of damage from external sources or
debris in the line. The regulator should be inspected for damage
after any overpressure condition.
Startup
The regulator is factory set at approximately the midpoint of the
spring range or the pressure requested, so an initial adjustment
may be required to give the desired results. With proper installation
completed and relief valves properly adjusted, slowly open the
upstream and downstream shutoff valves.
Adjustment
To change the outlet pressure, loosen the jam nut and turn
the adjusting screw clockwise to increase outlet pressure or
counterclockwise to decrease it. Monitor the outlet pressure with a
test gauge during the adjustment. Tighten the jam nut to maintain
the desired setting.
Taking Out of Service (Shutdown)
WARNING
!
To avoid personal injury resulting from sudden
release of pressure, isolate the regulator from all
pressure before attempting disassembly.
Parts List
Key Description
1 Body
2 Spring Case
3* Orifice
4* Valve Plug, Metal seat
4* Disk Holder Assembly, Composition seat
4a Disk Holder
4b Disk
4c O-ring, Type MR95HP only (not shown)
5 Valve Plug Guide
6 Stem/Stem Assembly
6a Stem
6b Pusher Plate
6b O-ring
6c O-ring
7 Stem Guide Bushing
8 Lower Spring Seat
9 Upper Spring Seat
10 Pusher Post, (not shown)
11 Control Spring
12* Diaphragm
13 Nameplate
14* Diaphragm Protector (not shown)
15 Adjusting Screw
16 Cap Screw
17 Jam Nut
18 Nameplate Drive Screw
19* Diaphragm Gasket
20 Pitot Tube (for constructions without control line)
21 Diaphragm Head Assembly,Types MR95L and MR95LD only
(not shown)
21a Diaphragm Head
21b Lower Spring Seat
21c Screw
21 Diaphragm Head (not shown)
22 Adjusting Screw Assembly (Tee Handle Adjustment)
23 Handwheel (not shown)
26 Inner Valve Spring
27 Inner Valve Base (not shown)
27 Inner Valve Base Assembly, Type MR95HP only (not shown)
29* Gasket (not shown)
31 Locknut (not shown)
32 Stuffing Box
33 Adjusting Screw
34 Packing Follower
35 Stuffing Box Nut
36 Packing
37* Stuff Box Gasket
38 Handwheel/Handle
39 Internal Adaptor
40 External Adaptor
41 Machine Screw
41 Jam Nut, Types MR95HD and MR95HDP only
42 Spring
43 Washer
44 Washer
45* O-ring, Types MR95HD and MR95HDP only (not shown)
47 NACE Tag (not shown)
48 Tag Wire (not shown)
49 Lockwasher (not shown)
50* Sealing Washer
51 Vent, Type Y602-12 (not shown)
52 Plug
62 Adaptor, Types MR95L and MR95LD only (not shown)
63* Bottom Plug Seal
64 Flow Arrow
65 Pipe Plug (not shown)
66 Inlet Pressure Gauge (not shown)
67 Outlet Pressure Gauge (not shown)
69 ATEX Tag (not shown)
70 PED Tag (not shown)
*Recommended Spare Part
1. Only one metal diaphragm is needed for Types MR95L and MR95LD with 1/4 NPT body
size and 0.14 to 0.41 bar / 2 to 6 psi spring range.
(1)
3
Page 4
MR95 Series
50
L2
L2
OR
L1
L4
15
2
11
21B
(2)
16
7
4
26
(3)
63
13
6
18
17
9L2
21C
21A
3
5
SEALED ADJUSTING
SCREW OPTION
T
12
TEE-HANDLE OPTION
1
20
L2
L2
COMPOSITE SEAT OPTION
6B
52
6C
22
4B
4A
L1
L2
L2
L3 36
43
L1
11
L2
7
L1
OR
L4
6A
CONTROL LINE OPTION
12
64
GF04915
APPLY LUBRICANT OR SEALANT
T = THREAD LOCKER
L1 = GENERAL PURPOSE PTFE OR LITHIUM GREASE
L2 = ANTI-SEIZE COMPOUND
L4 = GRAPHITE SEALANT
1. Lubricants and sealants must be selected such that they meet the temperature requirements.
2. Apply L2 (anti-seize compound) on key 16 for Stainless steel bolts.
3. Apply L4 (graphite sealant) instead of L1 (general purpose PTFE or lithium grease) on key 63 for graphite ring.
18
METAL DIAPHRAGM OPTION
(1)
:
19
GF04918
41
33
44
38
34
35
32
37
42
2
(2)
16
39
40
9
L2
8
12
1
4
26
(3)
63
4B
4A
20
METAL DIAPHRAGM OPTION
6
L2
3
L2
5
6B
6A
CONTROL LINE OPTIONCOMPOSITION SEAT OPTION
APPLY LUBRICANT
L1 = GENERAL PURPOSE PTFE OR LITHIUM GREASE
L2 = ANTI-SEIZE COMPOUND
L4 = GRAPHITE SEALANT
(1)
:
19
12
52
L1
6C
Figure 1. Type MR95L, 1/4 NPT and DN 15 to 25 /
1/2 to 1 In. Body Sizes Assembly
Webadmin.Regulators@emerson.com
Fisher.com
Emerson Automation Solutions
Americas
McKinney, Texas 75070 USA
T +1 800 558 5853
+1 972 548 3574
Europe
Bologna 40013, Italy
T +39 051 419 0611
For further information on the current
PED revision see Bulletin: D103053X012
or scan the QR code.
The distinctive diamond shape cast into every spring
case uniquely identifies the regulator as part of the
Fisher™ brand and assures you of the highest-quality
engineering, durability, performance, and support.
Facebook.com/EmersonAutomationSolutions
LinkedIn.com/company/emerson-automation-solutions
Twitter.com/emr_automation
Asia Pacic
Singapore 128461, Singapore
T +65 6777 8211
Middle East and Africa
Dubai, United Arab Emirates
T +971 4 811 8100
Figure 2. Types MR95HD and MR95HDP,
1/4 NPT and DN 15 to 50 / 1/2 to 2 In. Body Sizes Assembly
The contents of this publication are presented for information purposes
only, and while effort has been made to ensure their accuracy, they are
not to be construed as warranties or guarantees, express or implied,
regarding the products or services described herein or their use or
applicability. All sales are governed by our terms and conditions, which
are available on request. We reserve the right to modify or improve the
designs or specications of our products at any time without notice.
Emerson Process Management Regulator Technologies, Inc does not
assume responsibility for the selection, use or maintenance of any
product. Responsibility for proper selection, use and maintenance of any
Emerson Process Management Regulator Technologies, Inc. product
remains solely with the purchaser.
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.