6 | Fisher® Power Solutions
The Condensate System
Condensate Pump Recirculation Valve
As one of the most critical pieces of equipment in a power plant, the condenser provides a high vacuum
environment where the turbine output and efciency is
maximized and the exhaust is condensed to water. It is a condensate collection point for the steam generator.
From the condenser, the condensate ows into
the condensate pump and then through the other components in the condensate system.
In order to protect pumps from overheating and to prevent cavitation, Fisher pump recirculation valves withstand varying outlet conditions by providing the recommended
minimum ow of condensate through the pump.
®
condensate
PRODUCT FEATURES
nAdvanced sealing technology prevents seat damage and eliminates condensate leakage. n High rangeability protects the pump from damage and provides excellent system control. n Anti-cavitation trim reduces noise and vibration for extended service life. n Characterized cage provides low-ow cavitation protection during initial operation and necessary ow as
pressure rises.
nOptional trim allows passing of 19 mm (.75 inch) particulate. n Optional reducers engineered to meet piping requirements.
Page 7
Deaerator Level Control Valve
The deaerator serves many functions in a power plant. Its primary function is to minimize entrained oxygen in the feedwater. It must also provide
additional heat to the feedwater owing to the
boiler and store an adequate amount of feedwater to
provide sufcient suction head to the feedpump. This
is a challenging application and requires a valve that
can handle cavitating, low ow rates during startup
and allows for high capacity at low pressure drops during normal operation.
In order for the deaerator to serve all of its functions
properly and efciently, consistent deaerator level
must be maintained.
Fisher deaerator level control valves maintain a consistent deaerator level while handling extreme
ow rates and minimizing the effects of cavitation.
Fisher® Power Solutions | 7
PRODUCT FEATURES
nAdvanced sealing technology provides tight shutoff and maintains consistent deaerator level during startup. n High turndown handles extreme flow rates. n Anti-cavitation trim reduces noise and vibration for extended service life. n Characterized cage provides low-ow cavitation protection during initial operation and necessary ow as
pressure rises.
nOptional trim allows passing of 19 mm (.75 inch) particulate. n High thrust, low maintenance pneumatic actuator.
Page 8
8 | Fisher® Power Solutions
The Feedwater System
Boiler Feedwater Startup and Regulator Valve
In the normal range of plant operation, the boiler
feedwater regulator experiences high ow rates with
low differential pressure. However, during startup,
this valve experiences low ow rates with very
high differential pressure, which can cause severe cavitation damage. Some feedwater systems are designed using one valve to handle startup and normal operating conditions. Others are designed using a separate small startup valve to
handle low ow, cavitating conditions and a second larger valve to handle high ow rates required for
normal operation.
Fisher feedwater startup and regulator valves are engineered to eliminate cavitation during initial operation and provide the rangeability required for smooth transition from startup through full load operation.
HP/IP Drum Level Control Valve
The high pressure (HP) and intermediate pressure (IP) drum level control application is fairly moderate during typical plant operation. However, during startup the pressure drop across the valves, particularly the HP drum level control valve, can produce damaging cavitation.
Fisher HP and IP drum level control valves are designed to eliminate cavitation during startup while providing the rangeability required for smooth transition to normal operation.
PRODUCT FEATURES
nAdvanced sealing technology provides tight shutoff and extends service life. n High turndown handles extreme flow rates. n Characterized cage provides low-ow cavitation protection during initial operation and necessary
ow as pressure rises.
nOptional trim allows passing of 19 mm (.75 inch) particulate. n One valve solution: offers anti-cavitation protection during low flow, high pressure drop
startup, and unrestricted high flow during low pressure drop, full load conditions.
n Two valve solution: offers a dedicated startup valve to handle cavitating conditions in parallel with
a larger standard trim valve, handling full load conditions.
n Pneumatic piston actuator provides highly accurate step positioning and stable valve response.
Page 9
Boiler Feedpump Recirculation Valve
The boiler feedpump recirculation valve faces some of the toughest conditions of any control valve in a power plant. The boiler feedpump takes its suction from the deaerator at relatively low pressure, and increases the pressure to approximately 10% above the main steam pressure. During startup or low load
conditions, ow to the boiler may not be adequate to meet the minimum ow requirements of the
boiler feedpump.
Fisher boiler feedpump recirculation valves protect
the feedpump by ensuring adequate ow is passing
through the pump at all times. They are engineered to handle extreme cavitation caused by high temperatures and pressure drops. Where issues
with ow accelerated corrosion exist, Fisher boiler
feedpump recirculation valves allow high levels of entrained particulate to pass.
Fisher® Power Solutions | 9
PRODUCT FEATURES
nControls pressure drops up to 586 bar (8,500 psi). nAdvanced sealing technology provides tight shutoff and extends service life. n High turndown handles extreme flow rates. n Anti-cavitation trim reduces noise and vibration for extended service life. n Characterized cage provides low-ow cavitation protection during initial operation and necessary ow as
pressure rises.
nOptional trim allows passing of 19 mm (.75 inch) particulate. n Globe and angle body designs available. n Pneumatic piston actuator provides highly accurate step positioning and stable valve response.
Page 10
10 | Fisher® Power Solutions
The Main Steam System
Superheat Spray Valve
Varying load requirements cause varying steam temperatures. In order to ensure optimum heat rate and to protect the steam turbine, the steam temperature in the superheat sections of the boiler must be controlled.
Fisher superheat spray valves accurately control the amount of water injected into the steam attemperator or cooler, providing optimal main steam temperature control and stability. This prevents damage to the turbine and
results in efcient turbine operation.
Reheat Spray Valve
To increase the thermal efciency of a steam generator
and improve the overall heat rate of a unit, a reheater is incorporated in the power cycle. This is a particularly challenging application and requires a reheat spray valve to maintain precise reheat temperature control.
Fisher reheat spray valves provide optimal hot reheat steam temperature control and high rangeability, while minimizing the damaging effects of cavitation.
Sootblower Valve
When ring fuels such as coal, oil, or other waste
products, degradation of the boiler tubes becomes a concern. Deposits from the combustion process can collect on the heat exchanging tubes, which reduces
thermal efciency and may cause operational problems.
Fisher sootblower valves provide steam to the sootblower system to remove deposits from the boiler tubes while withstanding high pressure, high vibration,
and thermal cycling to maintain unit efciency.
PRODUCT FEATURES
n High rangeability for excellent system control. n Advanced sealing technology provides Class V shutoff and extends service life. n Customized sootblower trim reduces noise and withstands heavy vibration. n Anti-cavitation trim reduces noise and vibration.
Page 11
HP/IP/LP Turbine Bypass Spraywater Valve
Turbine bypass spraywater valves serve a similar function to that of the other spraywater valves in a power plant. Rather than precisely controlling temperature, these valves provide adequate water to the desuperheater to bring the steam temperature to near saturation temperature. This occurs when turbine bypass applications are discharging into the condenser.
When HP bypass applications discharge to cold reheat, adequate water must be provided to reduce the main steam temperature to cold reheat temperature. Similarly, for hot reheat bypass applications discharging to LP steam,
sufcient water must be provided to reduce hot reheat
temperature to LP steam temperature.
Fisher HP, IP, and LP turbine bypass spraywater valves provide accurate steam temperature and mimic actual process conditions of a normally operating power plant, providing precise water injection.
Fisher® Power Solutions | 11
PRODUCT FEATURES
PRODUCT FEATURES
n Optimized in combination with turbine bypass valves. n High rangeability for excellent system control. n Advanced sealing technology provides Class V shutoff and extends service life. n Anti-cavitation trim reduces noise and vibration.
Page 12
12 | Fisher® Power Solutions
The Main Steam System
HP/IP/LP Turbine Bypass Valve
Turbine bypass systems are essential for the exible
operation of combined cycle power plants, as well
as large modern coal red plants. Turbine bypass
systems permit operation of the steam generator independently of the turbine during startup, shutdown, and plant upset conditions. They must be adequately sized to meet the needs of normal startup and shutdown, as well as transients. They must also operate at acceptable noise levels.
Fisher turbine bypass systems enhance operational
exibility during transient operating conditions. As a
result, startup times are reduced and equipment life and overall plant availability is increased.
PRODUCT FEATURES
n Custom designs meet piping arrangements. n Noise abatement technology and rugged cage guiding reduces noise levels to provide smooth and
stable operation.
n Variable geometry spray nozzles ensure complete mixing and rapid vaporization of spray water for efcient
temperature control.
n Repeatable Class V shutoff at temperatures up to 593° C (1100° F). n Enhanced designs engineered to withstand high thermal cycling applications. n High rangeability for excellent system control. n Pneumatic piston actuator for highly accurate step positioning and stable valve response.
Page 13
Deaerator Pegging Steam Valve
The deaerator pegging steam valve provides steam that gives positive pressure to the deaerator or IP and LP drum to prevent air from being drawn into the feedwater system during plant start up. Steam from this valve also heats the feedwater. Steam may come from a low pressure package boiler or the plant main steam line.
Fisher pegging steam valves ensure pressure reduction and noise attenuation, regardless of steam source.
Steam Seal Regulator Valve
Steam seal regulator systems have several valves that experience varying conditions. The steam seal feed valve takes full main steam pressure down to 0.2 - 0.3 bar (3-5 psig). This extreme pressure drop presents several challenges including noise and vibration.
Fisher® Power Solutions | 13
Fisher steam seal regulator valves contain noise abatement trim to combat to these tough challenges.
PRODUCT FEATURES
n Noise abatement technology reduces the harmful effects of noise and vibration. n Optional in-line diffuser for additional noise abatement. n Rugged design engineered to withstand full main steam pressure drop. n Advanced sealing technology provides Class V shutoff and extends service life. n Pneumatic piston actuator for highly accurate step positioning and stable valve response.
Page 14
14 | Fisher® Power Solutions
Sky Vent System
Sky Vent Valve
Sky vent valves may operate during startup and shutdown of the heat recovery steam generator, bypassing main steam around the steam turbine to the atmosphere.
Fisher sky vent valves are engineered to withstand the full pressure drop that occurs as the valve dumps high pressure and temperature steam directly to the atmosphere. They operate quietly during dump operation and provide tight shutoff during normal operation, preventing valuable steam leakage.
PRODUCT FEATURES
n Advanced sealing technology provides tight shutoff and extends service life. n Noise abatement technology reduces the harmful effects of noise and vibration. n Components engineered for high temperature service.
Page 15
Desuperheaters
Ring Style Attemperator
As with any superheated steam cycle, the temperature of the superheat needs to be controlled to ensure that it does not exceed the material limits of the steam turbine and boiler. Temperature control is accomplished by use of an attemperator or desuperheater that injects a controlled amount of
cooling water into the superheated steam ow.
Fisher ring style attemperators are designed to work in conjunction with supporting superheat and reheat control valves to provide optimal steam temperature and stability. This prevents damage to the turbine and extends service life.
Fisher® Power Solutions | 15
PRODUCT FEATURES
n Flexible designs from NPS 8 to 48. n Optional liner prevents thermal cracking caused by water impingement on pipe. n High turndown for high efciency. n Variable geometry spray nozzles ensure complete mixing and rapid vaporization of spray water for efcient
temperature control.
Page 16
16 | Fisher® Power Solutions
Desuperheaters
Insertion Style Attemperator
Fisher insertion style attemperators are designed to work in conjunction with supporting superheat
and reheat control valves. Proven Fisher anti-ashing
nozzles provide the required amount of water needed for accurate temperature control in the steam turbine and boiler. They are suitable for temperatures up to 593° C (1100° F) and standard pressure classes up to ANSI 2500.
PRODUCT FEATURES
n Vortex shedding technology minimizes vibration and extends service life. n NPS 3, 4, and 6 available for pipes up to 152 centimeters (60 inches) diameter. n Water ange connection offers high rangeability for excellent system control. n Solutions available for a wide range of steam velocities. n Variable geometry spray nozzles ensure complete mixing and rapid vaporization of spray water for efcient
temperature control.
Page 17
Heater Drain System
HP/LP Feedwater Heater Normal Drain Valve
Proper functioning of the heater drain system is critical to maintaining optimum heat rate and protecting the turbine from possible water induction. The feedwater heater normal drain valves must provide stable feedwater heater level control.
The Fisher HP and LP feedwater heater normal drain valves provide level control optimized to the
characteristics of each specic feedwater heater and prevent the damaging effects caused by ashing.
HP/LP Feedwater Heater Emergency Drain Valve
Feedwater heater emergency drain valves normally operate closed, and tight valve shutoff is critical. A leaking emergency drain can have a 2-5-plus megawatt negative impact on plant output.
Fisher® Power Solutions | 17
Fisher feedwater heater emergency drain valves operate quickly and properly to maintain consistent feedwater heater level when called upon and prevent
damage incurred by ashing.
PRODUCT FEATURES
n Body materials eliminate erosion caused by ashing. n Linear valve trim optimized to each feedwater heater eliminates noise and cavitation. n Advanced sealing technology provides Class V shutoff and extends service life. n Precise level control without oscillation. n Globe, angle, and rotary designs available.
Page 18
18 | Fisher® Power Solutions
Fuel Gas System
Fuel Control Valve
The primary function of the fuel control valve is to provide fuel to the combustion turbine. The challenge of this application is that the fuel control valve must be designed to work in conjunction with other fuel control and air valves supporting operation of the combustion turbine. Depending upon the age and frame size, the number of fuel control valves can vary from one to many and may differ in size.
Fisher fuel control valves are designed to work in conjunction with supporting fuel and air control
valves to improve efciency of the gas turbine. They
eliminate start up issues related to inaccurate level of the control valve. Their quick response enhances a turbine-driven generator’s ability to respond to step changes.
PRODUCT FEATURES
n Proven, optimized designs customized to the specic need of combustion turbine application. n Rotary valve design provides high rangeability for excellent system control. n Globe and angle valves available. n 3-way valves for fuel control in older turbine designs. n Custom trim designs available for extended service life.
Page 19
Fisher® Power Solutions | 19
Capabilities Serving You For the Life of Your Plant
If it’s your responsibility to select the right valve for a tough critical power application, you need every advantage you can get. Not just now, but in the future, too. From application expertise to valve repair, you can count on Emerson for quality, service, and expertise for the life of your plant.
Application Expertise
We understand that control valves are an investment. You want to speak one-on-one with someone who knows your tough application needs. The Emerson sales network has extensive application experience and partners with you to engineer the most suitable products for your application.
At Emerson, we’ve built our reputation not just on our breadth of reliable Fisher products, but also on our people and their dedication to service. Wherever you are, there is an Emerson sales engineer ready to discuss your control needs.
Manufacturing
Wherever your power plant is located and wherever you need to be, Fisher control valves are fully supported. Fisher manufacturing plants are located in every world area and are equipped with sophisticated manufacturing technology, ensuring that operations utilize the most up-to-date product information. This means that each Fisher product
meets design specications and perform as intended,
regardless of where its individual components were manufactured.
Global Reach, Local Service
We have the most extensive global network of
eld specialists anywhere. Whether it’s startup and
commissioning, turnaround planning and execution, valve repair or parts, Emerson understands the relationship between its prompt service and support
and your protability. With facilities at strategic
locations around the world, Emerson valve service centers give you fast turnaround of emergency and routine valve repairs. These services free up your maintenance personnel for other activities, while proving to be timesaving and cost effective.
Page 20
Experience our full breadth of reliable Fisher control valves and instruments for your tough power applications. To contact your
local sales ofce, visit www.EmersonProcess.com/Fisher
http://www.Facebook.com/FisherValves
http://www.Twitter.com/FisherValves
Emerson Process Management
Marshalltown, Iowa 50158 USA Sorocaba, 18087 Brazil Chatham, Kent ME4 4QZ UK Dubai, United Arab Emirates Singapore 128461 Singapore
www.EmersonProcess.com/Fisher
D351920X012 / MU49 (H:) / May12
http://www.YouTube.com/user/FisherControlValve
http://www.LinkedIn.com/groups/Fisher-3941826
© 2012 Fisher Controls International LCC. All rights reserved.
Fisher is a mark owned by one of the companies in the Emerson Process Management business division of Emerson Electric Co. Emerson Process Management, Emerson, and the Emerson logo are trademarks and service marks of Emerson Electric Co. All other marks are the property of their respective owners.
The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available upon request. We reserve the right to modify
or improve the designs or specications of such products at any time without notice. Neither Emerson, Emerson Process Management, nor any of their afliated entities assumes responsibility for the selection,
use, or maintenance of any product. Responsibility for proper selection, use, and maintenance of any product remains solely with the purchaser and end user.
Loading...