Emerson CH Tanks Data Sheet

Transducerized Cleaning Tanks
Ultrasonic Cleaning
Transducerized Cleaning Tanks and Immersible Transducers
Branson manufactures five standard size transducerized 25 and 40kHz tanks that range from a 2.5 to a 50 gallon capacity (10 to 190 liters). All have drains and fills.
Type 316L bright-annealed stainless steel construction throughout permits the use of alkaline, mildly acidic, or neutral aqueous solutions. Branson tanks are available with or without integral heaters. Heated models are available to maintain solution temperatures up to 170oF (76oC). All models are available with a stainless steel parts basket and/or tank cover.
STANDARD FEATURES
Bottom-mounted positive drain
connection.
Fully shielded internal components.
OPTIONS
Stainless steel basket for parts
handling.
Stainless steel tank cover.
Thermostatically-controlled heat.
NUMBERING SYSTEM
Each Branson transducerized tank has a model number which contains impor­tant information to guide the selection of a properly rated comparison power supply. When making a selection, note the frequency.
For example: CH1012-40-12
This model number, stamped on the tank nameplate, indicates whether the tank has a heater (H = heated), the length of the tank in inches, left to right (10”), the width of the tank in inches, front to back (12”), the operating frequency (40kHz), and the number of attached piezoelectric transducer elements (12).
POWER SUPPLY SELECTION
To select the correct power supply for your transducerized tank, add the total number of transducer elements involved by using the information from the model number as explained. Then, select a power supply whose last two numbers exactly match the num­ber of transducer elements by referring
HEATED TANK SPECIFICATIONS
Model 610** Model 1012 Model 1216 Model 1620 Model 2024 Model 2032***
Tank 6” x 10” x 10” 10” x 12” x 10” 12” x 16” x 12” 16” x 20” x 16” 20” x 24” x 20” 20” x 32” x 20” Dimensions* (152 x 254 x 254 mm) (254 x 304 x 254 mm) (304 x 406 x 304 mm) (406 x 508 x 406 mm) (508 x 610 x 508 mm) (508 x 812 x 508 mm)
Overall
10” x 14” x 14.62” 14” x 16” x 15.62” 16” x 20” x 17.62” 20” x 24” x 21.75” 24” x 28” x 25.75” 26” x 36” x 25.75”
Dimensions* (254 x 355 x 356 mm) (356 xw406 x 397 mm) (406 x 508 x 447 mm) (610 x 609 x 552 mm) (609 x 711 x 654 mm) (660 x 914 x 654 mm
Capacity
Heater Wattage
Power Equipment 4.2 amps 8.4 amps 8.3 amps 12.5 amps 12.5 amps 22 amps
Approx. Shipping Wt. 35 lbs. (16 kg) 44 lbs. (20 kg) 68 lbs. (31 kg) 115 lbs. (52 kg) 165 lbs. (75 kg) 195 lbs. (89 kg)
* All dimensions are in order, left-to-right, front-to-back, and top-to-bottom. Allow 6 inches (153mm) clearance on front-to-back dimensions for connections. Bench mounting of tank requires bottom support.
** No fill
*** #8 polished stainless steel
to the power supply specifications on Bulletin S-1044 (Series 8500) or S1043 (Series 8300).
IMMERSIBLE TRANSDUCERS
Branson immersible ultrasonic trans­ducers can be placed wherever you need them in your existing cleaning tanks. These units give you the com­plete freedom to design specialized cleaning setups or to upgrade soak tanks with ultrasonics.
Each immersible transducer is fabri­cated from 316L bright annealed stainless steel with welded seams and stainless steel fittings. These hermeti­cally sealed modular components are available in standard sizes starting at 6” x 18” - all 3.25” deep. Other sizes can be custom-built for special appli­cations. Chrome plating is available to reduce cavitation erosion.
2.5 gallons (9.4 liters) 5.0 gallons (18.9 liters) 10 gallons (37.8 liters) 20 gallons (75.7 liters) 40 gallons (151.4 liters) 50 gallons (189.2 liters)
500 Watts 1000 Watts 2000 Watts 3000 Watts 3000 Watts 5000 Watts
120 V/IØ 120 V/IØ 220 V/IØ 220 V/IØ 220 V/IØ 220 V/IØ
Branson offers three transducer con­figurations which vary according to
frequency (40kHz), and that it
contains 12 piezoelectric elements. their mounting style and electrical connections. This allows for maxi­mum versatility of transducer place­ment on tank bottom or walls to permit optimum ultrasonic energy transmission. Whatever the configu­ration, Branson supplies all neces-
sary interconnecting components.
POWER SUPPLY FREQUENCY
SELECTION
Branson immersible transducers
may be used singly or in multiples,
powered by a Branson generator of
suitable capacity. The power supply
and all transducers must operate at
the same frequency. To select the
NUMBERING SYSTEM
Each Branson immersible transducer has a model number which contains important information useful for selection of a properly rated com­panion power supply.
For example: FC618-40-12 This model number, stamped on the transducer nameplate, indicates, a type FC mounting, the size of 6” wide by 18” long, the operating
correct power supply for a cleaning
setup, add the total number of
transducer elements involved by
using the information from the
model number as explained. Then,
select a power supply whose last two
numbers exactly match the number
of transducer elements. Multiple
power supplies may be required.
Refer to the power supply specifica-
tions chart on the front of this sheet.