Emerson CF410WBS00, CF850GES00, CF410WORB00, CF850VNB00, CF410AORB00 Owner's Manual

Part No. F40BP74430000 Form No. BP7443
U.L. Model No.: CF850
READ AND SAVE THESE INSTRUCTIONS
52” Wet Location
Ceiling Fan Owner's Manual
CF850AW00 CF850GES00 CF850VNB00
Model Numbers
SUMMERHAVEN
Net Weight: 23.8 Lbs.
WARNING: To avoid fire, shock, and serious personal injury, follow these instructions.
Safety Instructions
1. Read your owner’s manual carefully and keep it for future reference.
2. Before servicing or cleaning unit, switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a warning device, such as a tag, to the service panel.
3. Be careful of the fan and blades when cleaning, painting, or working near the fan. Always turn off the power to the ceiling fan before servicing.
4. Do not put anything into the fan blades while they are turning.
5. Do not operate reversing switch until fan blades have come to a complete stop.
Additional Safety Instructions for Installation
1. To avoid possible shock, be sure electricity is turned off at the fuse box before wiring, and do not operate fan without blades.
2. All wiring must be in accordance with the National Electrical Codes “ANSI/NFPA 70-2008” and Local Electrical Codes. Use the National Electrical Code if Local Codes do not exist. The ceiling fan must be grounded as a precaution against possible electrical shock. Electrical installation should be made or approved by a licensed electrician.
3. The outlet box and joist must be securely mounted and capable of reliably supporting at least 50 pounds. Use only U.L. outlet boxes listed as “Acceptable for Fan Support of 22.7 kg. (50 lbs.) or less”, and use the mounting screws provided with the outlet box. Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt.
4. The downrod furnished with the fan provides the minimum recommended floor to fan blade clearance for an 8 foot ceiling.
5. The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental contact with the fan blades.
6. Follow the recommended instructions for the proper method of wiring your ceiling fan. If you do not know enough about electrical wiring, have your fan installed by a licensed electrician.
NOTE: All setscrews must be checked and re-tightened where necessary before installation. NOTE: This fan is suitable for use with solid-state speed controls. WARNING: To avoid fire, shock or injury, do not use an Emerson or any other brand of control not
specifically approved for this fan. WARNING: This product is designed to use only those parts supplied with this product and/or any
accessories designated specifically for use with this product by Emerson Electric Co. Substitution of parts or accessories not designated for use with this product by Emerson Electric Co. could result in personal injury or property damage.
WARNING: To reduce the risk of personal injury, do not bend the blade flange when installing the blade flanges, balancing the blades or cleaning the fan. Do not insert foreign objects in between rotating fan blades.
WARNING: To reduce the risk of electrical shock, this fan must be installed with an isolating wall control/switch.
NOTE: This fan is suitable for use in wet locations when installed in a GFCI protected branch circuit.
2
DATE CODE:
The date code of this fan may be found on the box, stamped in ink on a white label. You should record this data above and keep it in a safe place for future use.
U.L. Model No.: CF850
THIS FAN IS SUITABLE FOR WET LOCATIONS
SUCH AS COVERED PORCHES, COVERED PATIOS, AND COVERED DECKS...
ANYWHERE THERE IS A ROOF OVERHEAD.
!
WARNING
3
Unpacking Instructions
1. Check to see that you have received the following
parts:
NOTE: If you are uncertain of part description, refer to exploded view illustration.
a. Fan motor assembly b. One coupling cover c. One ceiling cover d. Five fan blades e. Five fan blades support plates f. One lower housing g. One light kit assembly including: one bowl cap and
one finial nut h. One hanger bracket i. One hanger ball/4.5” downrod assembly j. One lower glass k. Three 25-watt (maximum) candelabra base bulbs l. One loose parts bag containing:
1. One clevis pin
2. One hairpin clip
3. Three 12 ga. wire connectors
4. Two #8-32 x 1-1/4” threaded studs
5. Two #8 external tooth lockwashers
6. Two #8-32 knurled knobs
7. Sixteen #10 - 24 x 15mm washer head screws
8. One #8 - 32 x 10mm pan head screw
9. Two pull chain couplings
This Manual Is Designed to Make it as Easy as Possible for You to Assemble,
Install, Operate and Maintain Your Ceiling Fan
Tools Needed for Assembly
One Phillips head screwdriver One stepladder One 1/4” blade screwdriver One wire stripper
MATERIALS
Wiring outlet box and box connectors must be of type required by the local code. The minimum wire would be a 3-conductor (2-wire with ground) of the following size:
Installed Wire Length Wire Size A.W.G.
Up to 50 ft. 14
50-100 ft. 12
Before assembly your ceiling fan, refer to section on proper method of wiring your fan (page 8). If you feel you do not have enough wiring knowledge or experience, have your fan installed by a licensed electrician.
Do not install or use fan if any part is damaged or missing. Call Toll-Free:
1-800-654-3545
This product is designed to use only those parts supplied with this product and/or any accessories designated specifically for use with this product by Emerson Electric Co. Substitution of parts or accessories not designated for use with this product by Emerson Electric Co. could result in personal injury or property damage.
WARNING
!
WARNING
!
WARNING
!
10. Two wood pendants (large & small)
11. One balancing kit
NOTE: Place the parts from the loose parts bags in a small container to keep them from being lost. If any parts are missing, contact your local retailer or catalog outlet for replacement before proceeding.
2. Remove and discard the two cardboard shipping
retainers securing the motor hub in the motor housing assembly.
3. Remove the fan motor assembly from the
protective plastic bag. Place all carton contents on a protective surface.
U.L. Model No.: CF850
A. FAN MOTOR ASSEMBLY
B. COUPLING COVER
C. CEILING COVER
D. FAN BLADES
E. BLADE SUPPORT PLATES
F. LOWER HOUSING
H. HANGER BRACKET
J. LOWER GLASS
I. HANGER BALL/
4.5" DOWNROD ASSEMBLY
K. 25-WATT CANDELABRA BASE BULBS
G. LIGHT KIT ASSEMBLY
L. LOOSE PARTS BAG
4
U.L. Model No.: CF850
Electrical Requirements
How to Put Your Ceiling Fan Together
Figure 2
Figure 1
If your fan is to replace an existing ceiling light fixture, turn electricity off at the main fuse box at this time and remove the existing light fixture.
Your new ceiling fan will require a grounded electrical supply line of 120 volts AC, 60 Hz, 15 amp circuit.
The outlet box must be securely anchored and capable of withstanding a load of at least 50 pounds.
To avoid fire or shock, follow all wiring instructions carefully. Any electrical work not described in these instructions should be done or approved by a licensed electrician.
Turning off wall switch is not sufficient. To avoid possible electrical shock, be sure electricity is turned off at the main fuse box before wiring. All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock.
WARNING
!
Turning off wall switch is not sufficient. To avoid possible electrical shock, be sure electricity is turned off at the main fuse box before wiring. All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock.
WARNING
!
WARNING
!
To reduce the risk of fire, electrical shock, or personal injury, mount fan to outlet box marked “Acceptable for Fan Support of 22.7 kg. (50 lbs.) or less”, and use screws supplied with outlet box. Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt.
WARNING
!
1. Remove the hanger ball by loosening the setscrew
in the hanger ball until the ball falls freely down the
downrod (Figure 1). Remove the clevis pin from the
downrod, then remove the hanger ball. Retain the
pin and hanger ball for reinstallation in Step 5.
2. Loosen setscrew in motor coupling if necessary.
Separate, untwist and unkink the three 80” motor
leads. Route the motor lead wires through the
downrod. Align the clevis pin holes in the downrod
with the holes in the motor coupling. Install the
clevis pin and secure with the hairpin clip (Figure
2). The clevis pin must go through the holes in the
motor coupling and the holes in the downrod. Be
sure to push the straight leg of the hairpin clip
through the hole near the end of the clevis pin until
the curved portion of the hairpin clip snaps around
the clevis pin. The hairpin clip must be properly
installed to prevent the clevis pin from working
loose. Pull on the downrod to make sure the clevis
pin is properly installed.
It is critical that the clevis pin in the motor coupling is properly installed and the setscrews securely tightened. Failure to verify that the pin and setscrews are properly installed could result in the fan falling.
WARNING
!
PIN
HANGER BALL
DOWNROD
SETSCREW
SETSCREW (2)
CLEVIS PIN
CLEVIS PIN
SETSCREW
DOWNROD
DOWNROD
HAIRPIN CLIP
MOTOR COUPLING
HAIRPIN CLIP
MOTOR COUPLING
5
U.L. Model No.: CF850
How to Put Your Ceiling Fan Together (continued)
3. While pulling up on the downrod, securely tighten
the two setscrews in the motor coupling (Figure 3).
NOTE: The setscrews must be properly installed as described above, or fan wobble could result.
4. Make sure the grommet is properly installed in the
coupling cover then slide the coupler cover on the
downrod until it rests on the motor housing. Place
the ceiling cover over the downrod. Be sure both
the ceiling cover and the coupler cover are oriented
correctly (Figure 3).
5. Reinstall the hanger ball (Figure 4) on the downrod as
follows. Route the motor leads through the downrod.
Position the pin through the two holes in the downrod
and align the ball so the pin is captured in the groove
in the top of the hanger ball. Pull the hanger ball up
tight against the pin and securely tighten the setscrew
in the hanger ball. A loose setscrew could create fan
wobble.
6. The fan comes with blue, black and white leads
that are 80” long. Before installing fan, measure up approximately 6 to 9-inches above top of hanger ball/downrod assembly. Cut off excess leads and strip back insulation 1/2-inch from end of leads.
7. Turn fan motor assembly upside down in
preparation for mounting fan blades. Position the top and bottom halves of the styrofoam packaging on end, with solid styrofoam facing outward. Set side-by-side on the floor with a six to eight-inch gap between the halves (Figure 5). Carefully place the partially assembled ceiling fan on the styrofoam halves, with the hanger ball/downrod assembly positioned in the gap and the fan motor assembly resting on top of the styrofoam ends.
Figure 5
Figure 3
It is critical that the pin in the hanger ball is properly installed and the setscrew securely tightened. Failure to verify that the pin and setscrew are properly installed could result in the fan falling.
WARNING
!
Figure 4
PIN
HANGER BALL
SETSCREW
CEILING COVER
DOWNROD
COUPLING COVER
HANGER BALL
DOWNROD
PIN
SETSCREW
CEILING COVER
6" - 8" GAP
PARTIALLY ASSEMBLED FAN
SOLID STYROFOAM FACING OUT
Loading...