Emerson Botanica CF2500HTW01, Botanica CF2500TG01, Botanica CF2500OB01, Botanica CF2500S01 Owner's Manual

READ AND SAVE THESE INSTRUCTIONS
“Botanica” Series
Model No.
CF2500OB01 CF2500HTW01 CF2500S01 CF2500TG01
Botanica Series Ceiling Fan Owner's Manual
Part No. F40BP72200003 Form No. BP7220-3
Net Weight: 20.0 Lbs.
2
WARNING
!
WARNING: To avoid fire, shock, and serious personal injury, follow these instructions.
Safety Instructions
1. Read your owner’s manual carefully and keep it for future reference.
2. Before servicing or cleaning unit, switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a warning device, such as a tag, to the service panel.
3. Be careful of the fan and blades when cleaning, painting, or working near the fan. Always turn off the power to the ceiling fan before servicing.
4. Do not put anything into the fan blades while they are turning.
5. Do not operate reversing switch until fan blades have come to a complete stop.
Additional Safety Instructions for Installation
1. To avoid possible shock, be sure electricity is turned off at the fuse box before wiring, and do not operate fan without blades.
2. All wiring must satisfy National and Local Electrical Codes. Use the National Electrical Code if Local Codes do not exist. The ceiling fan must be grounded as a precaution against possible electrical shock. Electrical installation should be made or approved by a licensed electrician.
3. The outlet box and joist must be securely mounted and capable of reliably supporting at least 50 pounds. Use only U.L. outlet boxes listed as acceptable for fan support, and use the mounting screws provided with the outlet box. Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt.
4. The downrod furnished with the fan provides the minimum recommended floor to fan blade clearance for an 8 foot ceiling.
5. The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental contact with the fan blades.
6. Follow the recommended instructions for the proper method of wiring your ceiling fan. If you do not know enough about electrical wiring, have your fan installed by a licensed electrician.
WARNING: To avoid fire, shock or injury, do not use an Emerson or any other brand of control not specifically approved for this fan.
WARNING: This product is designed to use only those parts supplied with this product and/or any accessories designated specifically for use with this product by Emerson. Substitution of parts or accessories not designated for use with this product by Emerson could result in personal injury or property damage.
WARNING: To Reduce the risk of personal injury, do not bend the blade flange when installing the blade flanges, balancing the blades or cleaning the fan. Do not insert foreign objects in between rotating fan blades.
1. Open styrofoam unit containing fan. Remove top half of styrofoam unit. Remove parts and check to see that you have received the following:
a. Fan motor and housing assembly b. One motor cover c. One ceiling cover d. Five blade flanges e. One hanger ball/downrod assembly f. One hanger bracket g. One switch housing cover assembly h. One uplight lead assembly i. One loose parts bag containing:
1. One setscrew
2. One 5/32" hex wrench
3. One 3/16” hex wrench
4. Eleven 10-32 x 5/8" oval head screws
5. Two 1” threaded studs
6. Two 1-1/4” threaded studs
7. Four knurled knobs
8. Three wire connectors
9. Four 8-32 x 3/8" flat head screws
10. One pull chain pendant and coupling
11. One hairpin clip
12. One clevis pin
13. Four lockwashers
14. Sixteen 10-24 x 3/8" pan head screws
15. Sixteen flat washers
This Manual Is Designed to Make it as Easy as Possible for You to
Assemble, Install, Operate and Maintain Your Ceiling Fan
Tools Needed for Assembly
One Phillips head screwdriver One stepladder Three wire connectors (supplied.) One wire stripper
MATERIALS
Wiring, outlet box and box connectors must be of type required by the local code. The minimum wire would be a 3-conductor (2-wire with ground) of size shown at right:
3
Installed Wire Length Wire Size A.W.G.
Up to 50 ft. 14
50-100 ft. 12
Unpacking Instructions
For your convenience, check-off boxes are provided next to each step. As each step is completed, place a check mark in the box. This will insure that all steps have been completed and will be helpful in finding your place should you be interrupted.
NOTE: Place the parts from the loose parts bags in small containers to keep them from being lost. If any parts are missing, contact your local retailer or catalog outlet for replacement before proceeding.
NOTE: Fan blades are ordered separately and are packaged in separate carton.
Before assembling your ceiling fan, refer to section on proper method of wiring your fan. If you feel you do not have enough wiring knowledge or experience, have your fan installed by a licensed electrician.
WARNING
!
Do not install or use fan if any part is damaged or missing. Call Toll-Free:
1-800-654-3545
This product is designed to use only those parts supplied with this product and/or any accessories designated specifically for use with this product by Emerson. Substitution of parts or accessories not designated for use with this product by Emerson could result in personal injury or property damage.
WARNING
!
WARNING
!
UPLIGHT LEAD ASSEMBLY
LOOSE PARTS BAG
HANGER BRACKET
HANGER BALL/ DOWNROD ASSEMBLY
CEILING COVER
MOTOR COVER
SWITCH HOUSING COVER ASSEMBLY
FAN MOTOR AND HOUSING ASSEMBLY
FOAM PACKING
BLADE FLANGES
CARTON
Your new ceiling fan will require a grounded electrical supply line of 120 volts AC, 60 Hz, 15 amp circuit.
The outlet box must be securely anchored and capa­ble of withstanding a load of at least 50 pounds.
If you feel that you do not have enough electrical wiring knowledge or experience, have your fan installed by a licensed electrician.
4
SECTION A
Assembly Instructions
for Installing the CF2500 Ceiling
Fan with a SW375 Receiver and a
SR330 Remote Control or with a
SW350 Wall Control
1. Cut the white, blue, and black wires about 3" above the motor coupling (Figure 1). Strip insula­tion 1/2" from end of wires and install a wire connector on the black wire; this wire will not be used. Remove the wire connectors from the red and brown wires.
2. Loosen the setscrew in the hanger ball, slide the ball down the downrod, and remove the clevis pin. Then slide the hanger ball off the downrod (Figure 2). Retain all parts for reinstallation in step 11.
3. Push the wiring harness connector and the con­nector on the blue wire (both supplied with the SW375 Receiver and the SW350 Wall Control), and the connector on the uplight yellow lead assembly (supplied with the fan) through the downrod until they all extend about 4” out of the downrod (Figure 3).
4. Cut all wires approximately 3" from the end of the downrod’. Strip insulation 1/2" from end of wires.
Figure 1
Figure 2
Figure 3
IF THE CF2500 CEILING FAN IS BEING INSTALLED WITH ANY OTHER CONTROL METHOD, SKIP SECTION A AND GO TO SECTION B TO BEGIN ASSEMBLY INSTRUCTIONS.
Electrical Requirements
If your fan is to replace an existing ceiling light fixture, turn electricity off at the main fuse box at this time and remove the existing light fixture.
Uplight
This fan is supplied with a built-in uplight in the motor housing. This uplight does not have a built-in switch to turn it ON or OFF. A separate switch control must be used to operate the uplight. This can be done with a separate ON/OFF wall switch or one of the many Emerson Fan/Light Controls, such as the SW375 Receiver, SR330 Remote Control or SW95L Controls. The yellow lead supplied with this fan is the power lead for the uplight.
To reduce the risk of fire, electric shock, or personal injury, mount fan to outlet box marked acceptable for fan support, and use screws supplied with outlet box. Mos outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electri­cian if in doubt.
WARNING
!
Turning off wall switch is not sufficient. To avoid possible electrical shock, be sure electricity is turned off at the main fuse box before wiring. All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock.
WARNING
!
To avoid fire, or shock, follow all wiring instructions carefully.
Any electrical work not described in these instructions should be done or approved by a licensed electrician.
WARNING
!
The Emerson CF2500 Ceiling Fan is designed to be operated from a SR330 Remote Control, from a SW350 Wall Control with a SW375 Receiver, or from other fan/light controls. There are no controls supplied with the ceiling fan. If you are going to control your ceiling fan with a SR330 Remote Control or with a SW350 Wall Control, proceed to “SECTION A”. If you are to control your ceiling fan in any other manner, proceed to “SECTION B”.
INSULATE BLACK WIRE USING WIRE CONNECTOR
WHITE WIRE
YELLOW WIRE
MOTOR COUPLING
3"
BLACK WIRE
BLUE WIRE
REMOVE WIRE CONNECTORS FROM RED AND BROWN WIRES
MOTOR COUPLING SLOT
CLEVIS PIN
HANGER BALL
DOWNROD
SETSCREW
UPLIGHT YELLOW LEAD ASSEMBLY
WIRING HARNESS
4"
BLUE WIRE
DOWNROD
CUT HERE
3"
NOTE: Make sure the unused black motor lead is capped with a wire connector. Make sure all wire connectors are completely inside motor coupling cover and not pinched between the motor coupling cover and motor.
9. Screw two 1” threaded studs (supplied) into the
motor (Figure 6). Leave approximately 7/8” of the stud extending above the motor. Slide the motor cover over the downrod and rotate the cover until the threaded studs protrude; install two knurled knobs (supplied) to secure the cover.
10. Position the ceiling cover over the downrod. Be sure the cover is oriented correctly, with the large opening at the top (Figure 7).
Figure 6
Figure 5
5
5. Using wiring connectors (supplied), connect the white, red, blue, brown, and yellow wires from the downrod to the white, red, blue, brown and yellow wires of the ceiling fan (Figure 4). Wires must be connected color-to-color.
6. Fold all wires from the downrod into the slot in the motor coupling, slide the downrod down the wires and seat the downrod in the motor coupling. All wires and wire connectors should be placed through the motor coupling slot beneath the down­rod (See Figure 5).
7. Align the clevis pin holes in the downrod with the holes in the motor coupling. Install the clevis pin and secure with the hairpin clip. The clevis pin must go through the holes in the motor coupling and the holes in the downrod (Figure 5). Push the straight leg of the hairpin clip through the hole near the end of the clevis pin until the curved portion of the hairpin clip snaps around the clevis pin. The hairpin clip must be properly installed to prevent the clevis pin from working loose.
8. Install the setscrew (supplied in the loose parts bag) in the motor coupling and tighten using the 5/32” setscrew wrench (supplied) (Figure 5).
Figure 4
It is critical that the clevis pin in the motor coupling is properly installed and the setscrew securely tightened. Failure to verify that the pin and setscrew are properly installed could result in the fan falling.
WARNING
!
SW375 RECEIVER
WHITE WIRE
YELLOW WIRE TO YELLOW WIRE
BLUE WIRE TO BLUE WIRE
BLACK WIRE (NOT USED)
FAN HOUSING
WIRING HARNESS CONNECTOR
BLACK WIRE
DOWNROD
BLACK WIRE
WHITE WIRE
RECEIVER CONNECTOR
RED WIRE TO RED WIRE
BROWN WIRE TO BROWN WIRE
BLUE WIRE TO BLUE WIRE
WHITE WIRE TO WHITE WIRE
YELLOW WIRE TO YELLOW WIRE
LIGHT FIXTURE
FAN BLADES REMOVED FOR CLARITY
BLACK WIRE
120V SUPPLY
120V SUPPLY
TO
BLACK
BLACK
TO
LISTED GENERAL USE ON/OFF WALL SWITCH (MUST BE USED WITH SR330 REMOTE CONTROL)
WHITE WIRE
WHITE
SW350 WALL CONTROL
LEADS TO BE POSITIONED IN SLOT IN MOTOR COUPLING
SETSCREW
CLEVIS PIN
HAIRPIN CLIP
CLEVIS PIN
DOWNROD
HAIRPIN CLIP
MOTOR COUPLING
DOWNROD
CLEVIS PIN
MOTOR COUPLING
KNURLED KNOB
MOTOR COUPLING COVER
WIRE CONNECTORS
1" THREADED STUD
MOTOR
7/8"
17. Reinstall the switch housing assembly by passing the wires from the motor shaft through the collar, screw the assembly onto the motor shaft (Figure 11). Tighten the setscrew using the 5/32” hex wrench (supplied). Engage the connector from the switch housing to the motor connector. The two connectors are keyed and must be mated correctly before they can be engaged.
6
11. Reinstall the hanger ball on the downrod as follows. Route the motor leads through the hanger ball and slide the hanger ball over the downrod (Figure 7). Install the pin through the holes at the top of the downrod and slide the hanger ball up the downrod, aligning the ball so the pin is captured in the groove in the top of the hanger ball. Pull the hanger ball up tight against the pin and securely tighten the setscrew in the hanger ball. A loose setscrew could create fan wobble.
12.Use three 10-24 x 3/8" pan head screws and flat
washers (supplied) to secure flange to blade (blades ordered separately) (Figure 8). Repeat for the remaining four blades.
13.Using the 5/32” hex wrench (supplied), loosen the
setscrew in the collar and unscrew (counterclock­wise) the switch housing assembly from the motor shaft (Figure 9). Do NOT remove the flat washer from the motor shaft.
Figure 7
Figure 8
Figure 9
Figure 10
14.Use the 10 round recessed holes in the motor hub marked with "5" and install the five blade assemblies in accordance with Step 15.
15.Loosely attach one blade assembly to the motor hub using two 10-32 x 5/8" oval head screws (supplied) (Figure 10). Make sure the screws are NOT tightened at this time. Repeat this procedure for the four remaining blade assemblies.
16.The blade flanges have an interlocking feature that must be fully engaged before tightening the screws. Make sure all the flanges are properly engaged and then tighten the flange screws In a clockwise sequence. If one of the flanges does not seat properly on the motor hub, loosen the adjacent flange screws, re-engage and reseat the flanges, then tighten the screws again.
Figure 11
It is critical that the pin in the hanger ball is properly installed and the setscrew securely tightened. Failure to verify that the pin and setscrew are properly installed could result in the fan falling.
WARNING
!
To reduce the risk of personal injury, do not bend the blade flanges when installing the flanges, balancing the blades, or cleaning the fan.
WARNING
!
PIN
BLADE FLANGE
HANGER BALL
DOWNROD
CEILING COVER
SETSCREW
10-24 x 3/8" PAN HEAD SCREW (3)
FLAT WASHER (3)
BLADE
BLADE FLANGE
FLAT WASHER (DO NOT REMOVE)
10-32 X 5/8" OVAL HEAD SCREW (3 PER BLADE ASSEMBLY)
MOTOR HUB
COLLAR
SWITCH HOUSING ASSEMBLY
SETSCREW
SWITCH HOUSING CONNECTOR
COLLAR
SETSCREW
MOTOR CONNECTOR
SWITCH HOUSING ASSEMBLY
18. Securely attach the hanger bracket to the outlet box using the two screws supplied with the outlet box (Figure 13).
7
Figure 12
Figure 13
Figure 14
19. Carefully lift the fan and seat the hanger ball/downrod assembly on the hanger bracket that was just attached to the outlet box (Figure
14). Be sure the groove in the ball is lined up with tab on the hanger bracket (Figure 13).
20. Position the receiver (supplied with the SW330 Remote Control or SW350 Wall Control) by passing the opening in the receiver over the downrod (Figure 15).
21. Connect the black wire from the wiring harness to the black (hot) supply wire (Figure 4). Connect the white wire from the wiring harness to the white (neutral) supply wiring. Connect the green ground wires from the hanger bracket and the hanger ball to the supply ground wire. Use wire connectors supplied with your ceiling fan.
Figure 15
The outlet box must be securely anchored and capable of withstanding a load of at least 50 lbs.
WARNING
!
The fan must be hung with at least 7' of clearance from floor to blades (Figure 12).
WARNING
!
Hanger bracket must seat firmly against outlet box. If the outlet box is recessed, remove wall board until bracket contacts box. If bracket and/or outlet box are not securely attached, the fan could wobble or fall.
WARNING
!
To reduce the risk of fire, electric shock, or personal injury, mount fan to outlet box marked acceptable for fan support, and use screws supplied with outlet box. Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt.
WARNING
!
Failure to seat tab in groove could cause damage to electrical wires and possible shock or fire hazard.
WARNING
!
To avoid possible fire or shock, do not pinch wires between the hanger ball/downrod assembly and the hanger bracket.
WARNING
!
To avoid possible electrical shock, be sure electricity is turned off at the main fuse box before wiring.
NOTE: If you are not sure if the outlet box is ground­ed, contact a licensed electrician for advice, as it must be grounded for safe operation.
WARNING
!
Check to see that all connections are tight, including ground, and that no bare wire is visible at the wire connectors, except for the ground wire. Do not operate fan until blades are in place. Noise and fan damage could result.
WARNING
!
CEILING
NOTE: CEILING COVER, SUPPLY WIRES AND FAN WIRES OMITTED FOR CLARITY.
OUTLET BOX
HANGER BRACKET
AT LEAST
7'
FLOOR
HANGER BALL/ DOWNROD ASSEMBLY
HANGER BRACKET
1/8" FOAM ADHESIVE PAD
SW375 RECEIVER
OPEN SIDE
FLAT SIDE
HANGER BALL
TWO SCREWS SUPPLIED WITH OUTLET BOX
TAB
OUTLET BOX
HANGER BRACKET
CEILING COVER
22. Securely connect the wiring harness connector to the receiver connector, and connect the blue and yellow wires to the blue and yellow wires from the receiver (Figure 4).
23. Turn the receiver so that the flat side aligns with the open side of the hanger bracket (Figure 15). Fold and position the wires into the space above the hanger ball and into the outlet box.
24. Feed the wires and connectors around the out­side of the receiver, through the open side of the hanger bracket, and into the outlet box. Slide the receiver up and over the hanger bracket. Remove the backing on the foam adhesive pads and press the receiver against the ceiling.
25. To complete the ceiling fan assembly, skip to the “FINAL ASSEMBLY” section of this Owner’s Manual.
7. Route the white, blue, and black motor leads through the downrod. Fold the yellow, red, and brown wires into the slot in the motor coupling, slide the downrod down the wires and seat the downrod in the motor coupling (Figure 18).
8. Align the clevis pin holes in the downrod with the holes in the motor coupling. Install the clevis pin and secure with the hairpin clip (Figure 18). The clevis pin must go through the holes in the motor coupling and the holes in the downrod . Push the straight leg of the hairpin clip through the hole near the end of the clevis pin until the curved portion of the hairpin clip snaps around the clevis pin. The hairpin clip must be properly installed to prevent the clevis pin from working loose. Pull on the hanger ball to make sure the clevis pin is properly installed.
9. Install the setscrew (supplied in loose parts bag) in the motor coupling and tighten using the 5/32" setscrew wrench (supplied) (Figure 19).
8
SECTION B
Assembly Instructions for
Installing the CF2500 Ceiling Fan
with Any Other Control Method
(excluding the SW375 Receiver,
SR330 Remote Control or the
SW350 Wall Control)
1. Position the fan motor and housing assembly in the lower foam packing so that the top of the motor is facing you.
2. Separate, untwist and unkink the four motor leads.
3. Obtain the hanger ball/downrod assembly and
remove the hanger ball by loosening the setscrew in the hanger ball until the ball falls freely down the downrod (Figure 16). Remove the pin from the downrod , then remove the hanger ball. Retain the pin and hanger ball for reinstallation in step 9.
4. Push the uplight yellow lead assembly connector through the downrod (Figure 17) until it extends about 4”.
5. Cut the yellow lead approximately 3” from the end of the pipe. Strip insulation 1/2” from end of the wires.
6. Using the wire connector supplied, connect the uplight yellow lead assembly to the yellow lead from the fan motor and housing assembly (Figure 18).
Figure 16
Figure 17
It is critical that the clevis pin in the motor coupling is properly installed and the setscrew securely tightened. Failure to verify that the pin and setscrew are properly installed could result in the fan falling.
WARNING
!
Figure 18
CLEVIS PIN
HANGER BALL
DOWNROD
HAIRPIN
SETSCREW
CLEVIS PIN
HAIRPIN CLIP
CLEVIS PIN
CLIP
MOTOR COUPLING
DOWNROD
CLEVIS PIN
MOTOR COUPLING
DOWNROD
SETSCREW
4"
UPLIGHT YELLOW LEAD ASSEMBLY
DOWNROD
3"
CUT
HERE
14.Use three 10-24 x 3/8" pan head screws and flat washers (supplied) to secure flange to blade (blades ordered separately) (Figure 22). Repeat for the remaining four blades.
15.Using the 5/32” hex wrench (supplied), loosen the setscrew in the collar and unscrew (counterclock­wise) the switch housing assembly from the motor shaft (Figure 23). Do NOT remove the flat washer from the motor shaft.
16.Use the 10 round recessed holes in the motor hub marked with "5" and install the five blade assemblies in accordance with Step 17.
17.Loosely attach one blade assembly to the motor hub using two 10-32 x 5/8" oval head screws (supplied) (Figure 23). Make sure the screws are NOT tightened at this time. Repeat this procedure for the four remaining blade assemblies.
9
10.Screw two 1” threaded studs (provided) into the motor (Figure 20). Leave approximately 7/8” of the stud extending above the motor. Slide the motor cover over the downrod and rotate the cover until the threaded studs protrude; install two knurled knobs (supplied) to secure the cover.
NOTE: Make sure the red and brown leads are separately capped with wire connectors. Make sure red, brown, and yellow wire connectors are completely inside motor coupling cover and not pinched between the motor coupling cover and motor.
11. Position the ceiling cover over the downrod. Be
sure the cover is oriented correctly, with the large opening at the top (Figure 21).
12.Reinstall the hanger ball on the downrod as follows. Route the motor leads through the hanger ball and slide the hanger ball over the downrod (Figure 21). Install the pin through the holes at the top of the downrod and slide the hanger ball up the downrod, aligning the ball so the pin is captured in the groove in the top of the hanger ball. Pull the hanger ball up tight against the pin and securely tighten the setscrew in the hanger ball. A loose setscrew could create fan wobble.
13.The blue, black, yellow and white leads exiting the downrod are 80-inches long. Before installing fan, measure up approximately 6 to 9-inches above the ball/downrod assembly. Cut off excess leads and strip back insulation 1/2-inch from end of leads.
NOTE: If you are installing your fan with a SR330 Remote Control or SW350 Wall Control, Do Not Cut Terminal Off of the Yellow Lead. (See Section A.)
Figure 19
Figure 20
Figure 21
Figure 22
Figure 23
It is critical that the pin in the hanger ball is properly installed and the setscrew securely tightened. Failure to verify that the pin and setscrew are properly installed could result in the fan falling.
WARNING
!
DOWNROD
SETSCREW
MOTOR
PIN
HANGER BALL
DOWNROD
CEILING COVER
SETSCREW
10-24 x 3/8" PAN HEAD SCREW (3)
FLAT WASHER (3)
WIRE CONNECTORS
RED LEAD
BROWN LEAD
MOTOR
KNURLED KNOB
MOTOR COUPLING COVER
WIRE CONNECTOR YELLOW LEAD
1" THREADED STUD
7/8"
BLADE
BLADE FLANGE
BLADE FLANGE
FLAT WASHER (DO NOT REMOVE)
10-32 X 5/8" OVAL HEAD SCREW (3 PER BLADE ASSEMBLY)
MOTOR HUB
20. Securely attach the hanger bracket to the outlet box using the two screws supplied with the outlet box (Figure 27).
10
Figure 26
Figure 27
19. Reinstall the switch housing assembly by passing the wires from the motor shaft through the collar, screw the assembly onto the motor shaft (Figure 24). Tighten the setscrew using the 5/32” hex wrench (supplied). Engage the connector from the switch housing to the motor connector. The two connectors are keyed and must be mated correctly before they can be engaged (Figure 25).
Figure 25
21. Carefully lift the fan and seat the hanger ball/downrod assembly on the hanger bracket that was just attached to the outlet box (Figure 28). Be sure the groove in the ball is lined up with tab on the hanger bracket (Figure 27).
Figure 24
To reduce the risk of fire, electric shock, or personal injury, mount fan to outlet box marked acceptable for fan support, and use screws supplied with outlet box. Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt.
WARNING
!
The outlet box must be securely anchored and capable of withstanding a load of at least 50 lbs.
WARNING
!
The fan must be hung with at least 7' of clearance from floor to blades (Figure 26).
WARNING
!
Hanger bracket must seat firmly against outlet box. If the outlet box is recessed, remove wall board until bracket contacts box. If bracket and/or outlet box are not securely attached, the fan could wobble or fall.
WARNING
!
Failure to seat tab in groove could cause damage to electrical wires and possible shock or fire hazard.
WARNING
!
To reduce the risk of personal injury, do not bend the blade flanges when installing the flanges, balancing the blades, or cleaning the fan.
WARNING
!
18.The blade flanges have an interlocking feature that must be fully engaged before tightening the screws. Make sure all the flanges are properly engaged and then tighten the flange screws In a clockwise sequence. If one of the flanges does not seat properly on the motor hub, loosen the adjacent flange screws, re-engage and reseat the flanges, then tighten the screws again.
AT LEAST
7'
CEILING
SWITCH HOUSING ASSEMBLY
SETSCREW
COLLAR
FLOOR
MOTOR
SWITCH HOUSING CONNECTOR
COLLAR
SETSCREW
CONNECTOR
SWITCH HOUSING ASSEMBLY
OUTLET BOX
TWO SCREWS SUPPLIED WITH OUTLET BOX
TAB
HANGER BRACKET
11
NOTE: If you are installing a SR330 Remote Control or a SW350 Wall Control to operate the fan and light, refer to the installation instructions and wiring diagrams shown in Section A of this Owner’s Manual.
22. For a wall control installation you will need a
three-wire (with ground) conductor cable between the ceiling and wall outlet boxes. This will allow you to control the fan separately from the lights. Figure 29 is a basic wiring diagram that will con­trol the uplight and downlight on a switch and the fan on a separate control. Refer to the installation instructions and wiring diagrams supplied with the Emerson Fan Control Owner’s Manual.
a. Connect the green grounding lead from the
hanger ball and the green grounding lead from the hanger bracket to the grounding conductor of supply (this may be a bare wire or a wire with green colored insulation). Securely con­nect wires with wire connector supplied.
b. Securely connect the white wire from the
downrod to the supply white (neutral) wire using wire connector supplied. Securely con­nect the black wire from the downrod to the supply black (hot) wire using wire connector supplied.
c. Cut terminal off of the yellow lead wire and
strip insulation 1/2” from end of wire.
d. Securely connect the blue wire and yellow wire
from the downrod to the supply red (hot) wire using wire connector (supplied). After connec­tions have been made, turn leads upward and carefully push leads into the outlet box, with the white and green leads on one side of the outlet box and the black, blue and yellow leads on the other side of the outlet box.
FINAL ASSEMBLY
1. Screw the two 1-1/4” threaded studs (provided) into the tapped holes in the hanger bracket.
2. Lift the ceiling cover up to the threaded studs and turn until studs protrude through the holes in the ceiling cover (Figure 30).
3. Secure the ceiling cover in place by sliding lockwashers over the threaded studs and installing the two knurled knobs (supplied). (Figure 30.) Tighten the knurled knobs securely until the ceiling cover fits snugly against the ceiling and the hole in the ceiling cover is clear of the pipe.
4. Screw in three 40-watt (maximum) candelabra base lamps into the uplight sockets on top of the fan housing assembly.
Figure 29
Figure 30
NOTE: CEILING COVER,
Figure 28
23. To complete the ceiling fan assembly, proceed to
the “FINAL ASSEMBLY” section.
To avoid possible fire or shock, do not pinch wires between the hanger ball/downrod assembly and the hanger bracket.
WARNING
!
To avoid possible electrical shock, be sure electricity is turned off at the main fuse box before wiring.
NOTE: If you are not sure if the outlet box is ground­ed, contact a licensed electrician for advice, as it must be grounded for safe operation.
WARNING
!
Check to see that all connections are tight, including ground, and that no bare wire is visible at the wire connectors, except for the ground wire. Do not operate fan until blades are in place. Noise and fan damage could result.
WARNING
!
To avoid possible fire or shock, make sure that the electrical wires are completely inside the outlet box and not pinched between the ceiling cover and the ceiling.
WARNING
!
SUPPLY WIRES AND FAN WIRES OMITTED FOR CLARITY.
HANGER BALL/ DOWNROD ASSEMBLY
OUTLET BOX
HANGER BRACKET
EMERSON FAN CONTROL
LISTED OUTLET BOX
GREEN WIRE (GROUND) FROM HANGER BRACKET
GROUND WIRE
BLACK
GREEN WIRE (GROUND) FROM HANGER BALL
LISTED WIRE CONNECTOR (4)
BLACK FAN WIRE
RED
WHITE
BLUE
LIGHT CONTROL
GROUND
THREE - CONDUCTOR CABLE WITH GROUND BETWEEN CEILING AND WALL OUTLET BOXES
WHT.
GROUND
BLACK (HOT)
TO 120 VOLT SUPPLY
CEILING COVER
1-1/4" THREADED STUD
KNURLED KNOB
LOCKWASHERS (2)
Attaching Light Kit
To install an Emerson accessory light kit, remove the four screws securing the switch housing cover assembly to the switch housing. Remove the trim medallion from the bottom of the switch housing cover (Figure 32). Attach the light kit to the switch housing cover assembly with the lockwasher and nut supplied with the light kit (Figure 33). Install the light kit in accordance with the Emerson light kit Owner's Manual.
12
Using Your Ceiling Fan
1. Restore electrical power to the outlet box by turning the electricity on at the main fuse box.
2. When controlled by a wall switch check the operation of the fan by gently pulling on the 4-position speed control pull chain switch. The operating sequence is as follows:
THREE-SPEED
1st Pull — HIGH 2nd Pull — Medium 3rd Pull — Low 4th Pull — OFF
3.When operated by an Emerson Remote Control,
check operation of fan and light in accordance with the Remote Control Owner’s Manual.
4. If airflow is desired in opposite direction, turn your fan off and wait for the blades to stop turning. Then slide the reversing switch to the opposite position and turn fan on again. The fan blades will turn in the opposite direction and reverse the airflow.
Figure 31
Figure 32
To avoid possible electrical shock, be sure electricity is turned off at the main fuse box before wiring.
WARNING
!
Figure 33
5. Slip the pull chain through the bushing in the switch housing cover assembly (Figure 31). Position the cover assembly on the switch housing assembly with the reversing switch lever positioned in the slot provided. Secure the cover assembly to the switch housing assembly using four 8-32 x 3/8” flat head screws (provided).
6. Slip the switch pull chain through the hole in the pendant (supplied), then secure the pendant by snapping the coupling (supplied) onto the end of the chain.
TRIM MEDALLION
REVERSING SWITCH LEVER
SWITCH HOUSING COVER ASSEMBLY
BUSHING
SWITCH HOUSING ASSEMBLY
PULL CHAIN
8-32 X 3/8" FLAT HEAD SCREW (4)
REMOVE
REMOVE FLAT HEAD SCREW (4)
HEX SCREW
SWITCH HOUSING COVER ASSEMBLY
REMOVE TRIM MEDALLION
SWITCH HOUSING COVER ASSEMBLY
LOCKWASHER AND NUT (SUPPLIED WITH LIGHT KIT)
REVERSING SWITCH
SPEED CONTROL SWITCH PULL CHAIN
LIGHT KIT
Trouble Shooting
TROUBLE PROBABLE CAUSE SUGGESTED REMEDY
1.Fan will not start. 1.Fuse or circuit breaker blown. 1.Check main and branch circuit fuses or
circuit breakers.
WARNING: Make sure main power is turned off.
2.Loose power line connections to the fan, 2.Check line wire connections to fan and or loose switch wire connections in the switch wire connections in the switch switch housing. housing.
2.Fan sounds noisy. 1.Blades not attached to fan. 1.Attach blades to fan before operating.
2.Loose screws in motor housing. 2.Check to make sure all screws in motor
housing are snug (not over-tight).
3.Screws securing fan blade flanges to 3.Check to make sure the screws which motor hub are loose. attach the fan flanges to the motor hub
are tight.
WARNING: Make sure main power is turned off.
4.Wire connectors inside switch housing 4.Check to make sure wire connectors in
rattling. switch housing are not rattling against
each other or against the interior wall of the switch housing.
5.Screws holding blades to flanges are loose. 5.Tighten screws securely.
3.Fan wobbles 1.Setscrew in motor coupling is loose. 1.Raise motor cover and tighten setscrew excessively. securely.
2.Setscrew in hanger ball/downrod assembly 2.Tighten the setscrew in the hanger ball/ is loose. downrod assembly.
3.Screws securing fan blade flanges to motor 3.Check to be sure screws which attach hub are loose. the fan blade flanges to the motor hub
are tight.
4.Fan blade flanges not seated properly. 4.Check to be sure the fan blade flanges
seat firmly and uniformly to the surface of the motor hub. If flanges are seated incorrectly, loosen the flange screws and retighten according to step 15 or 17 in Sections “A” or “B” “Assembly Instructions”.
5.Hanger bracket and/or ceiling outlet box 5.Tighten the hanger bracket screws to the is not securely fastened. outlet box, and/or secure outlet box.
6.Fan blades out of balance. 6. Interchanging an adjacent (side-by-side)
blade pair can redistribute the weight and result in smoother operation. Or use supplied balancing kit to balance blades.
WARNING: FOR YOUR OWN SAFETY TURN OFF POWER AT FUSE BOX OR CIRCUIT BREAKER
BEFORE TROUBLE SHOOTING YOUR FAN.
IMPORTANT CARE INSTRUCTIONS
for your Ceiling Fan
Periodic cleaning of your new ceiling fan is the only maintenance that is needed.
When cleaning, use only a soft brush or lint free cloth to avoid scratching the finish.
Abrasive cleaning agents are not required and should be avoided to prevent damage to finish.
13
Do not use water when cleaning your ceiling fan. It could damage the motor or the blades and create the possibility of an electrical shock.
WARNING
!
!
!
!
Maintenance
30
Repair Parts
14
ACCESSORIES
1. Ceiling Fan Light Kits (see store or catalog).
2. Ceiling Fan/Light Controls (see store or catalog).
3. Downrod Extension Kits (see store or catalog).
Before discarding packaging material,
be certain all parts have been removed.
HOW TO ORDER REPAIR PARTS
WHEN ORDERING REPAIR PARTS, ALWAYS GIVE THE FOLLOWING INFORMATION:
• NAME OF ITEM
• MODEL NUMBER
• THE PART NUMBER
• THE PART DESCRIPTION For repair parts, phone 1-800-654-3545.
This product is designed to use only those parts supplied with this product and/or any accessories designated specifically for use with this product by Emerson. Substitution of parts or accessories not designated for use with this product by Emerson could result in personal injury or property damage.
The use of any other control not specifically approved for this fan could result in fire, shock and personal injury.
WARNING
!
WARNING
!
17
16
15
19
20
2
1
3
18
4
20 19
9
26
29
28
12
11
23 24
6
7
21
25
10
5
8
27
22
14
13
15
Repair Parts List
Ref.
Botanica Models
No. Description CF2500OB01 CF2500S01 CF2500HTW01 CF2500TG01
Hanger Pack, 761655-9 761655-16 761655-12 761655-13
containing: 1 Bracket, Hanger (1) — 2 Hanger Ball Assembly (1) — 3 Downrod (1)
4 Cover, Ceiling 761620-9 761620-24 761620-12 761620-23 5 Hub, Rubber 760601 760601 760601 760601 6 Blade Assembly * * * *
(Full set for one fan) 7 Flange Set 761885 761885-1 761885-2 761885-3
(Full set for one fan) 8 Switch Housing Assembly 761902 761902 761902-1 761902 9 Cover, Motor 761621-9 761621-16 761621-12 761621-13
10 Motor 762304 762304 762304 762304
Parts Bag, containing: 761907-1 761907-1 761907 761907-1
11 Pin, Clevis (1) — 12 Clip, Hairpin (1) — 13 Coupling (1) — 14 Pendant (1) — 15 Wire Connector (3) — 16 Wrench, Hex, 3/16” — 17 Wrench, Hex, 5/32” — 18 Stud, Threaded 1-1/4” (2) — 19 Lockwasher (4) — 20 Knob, Knurled (4) — 21 Screw, 10-32 x 5/8" (11) — 22 Screw, Flathead, 8-32 x 3/8" (4) — 23 Screw, 10-24 x 3/8" (16) — 24 Washer, Flat (16) — 25 Setscrew, 7/16-18 x 1/4" (1) — 26 Stud, Threaded, 1” (2)
27 Cover, Switch Housing Assembly 761889 761889-1 761889-2 761889-3 28 Aux. Capacitor 761453 761453 761453 761453 29 Screw, #8 Washerhead, 8-32 x 3/8” (4) — 30 Uplight Lead Assembly 761790 761790 761790 761790 — Owner's Manual BP7220-3 BP7220-3 BP7220-3 BP7220-3
*Contact your nearest authorized Emerson fan dealer for replacement B52 blade accessories.
Part No. F40BP72200003 Printed in Taiwan 04/03 Form No BP7220-3
LIMITED WARRANTY
What The Warranty Covers:
This warranty covers the motor and the other components and accessories of your Emerson ceiling fan against all defects in workmanship and materials. You must be the original purchaser or user of the product to be covered.
What The Period Of Coverage Is:
As it applies to the motor, this warranty will last for the lifetime of your ceiling fan. All other components and accessories are covered by this warranty for one year from the date you purchased your ceiling fan. ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, MADE WITH RESPECT TO COMPONENTS AND ACCESSORIES IS ALSO LIMITED TO ONE YEAR.
What Will Emerson Company Do To Correct Problems:
Emerson will replace a defective Emerson Air Comfort Ceiling Fan motor, blade, component or other accessory at no charge to you. If repair of the motor or blades is not practical or possible within a reasonable time and no replacement can be provided, Emerson will refund the actual purchase price of your fan. WE WILL SHIP THE REPAIRED PRODUCT OR REPLACEMENT TO
YOU AT NO CHARGE, BUT YOU ARE RESPONSIBLE FOR ALL COSTS OF REMOVAL, REINSTALLATION AND SHIPPING OF THE PRODUCT TO EMERSON.
How Can You Get Service:
YOU MUST HAVE PROOF OF YOUR PURCHASE OF THE CEILING FAN TO OBTAIN LIMITED WARRANTY SERVICE. KEEP YOUR RECEIPT OR OTHER PROOF OF PURCHASE. You can return the product to our factory or to your nearest authorized service center.
• To return the product to the factory, obtain a return authorization and service identification tag by writing to Air Comfort Products, Division of Emerson Company, 8100 W. Florissant Ave., St. Louis, MO 63136. Include all model numbers shown on the product with your request.
• To return the product to an authorized service center, call 1-800-654-3545 for the address of the nearest authorized service center.
You will be responsible for all insurance, freight or other transportation charges to our factory or authorized service center. Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage.
What Is Not Covered:
The glass globes and light bulbs of your ceiling fan are not covered by this warranty. This warranty also does not cover any defects, malfunctions or failures caused by:
• Repairs by persons not authorized by Emerson Company,
• Use of parts or accessories not authorized by Emerson Company,
• Mishandling, improper installation, modifications or damage to your ceiling fan while in your possession, or
• Unreasonable use, misuse, abuse, including failing to do reasonable and necessary maintenance, and normal wear and tear.
Additionally, this warranty and any implied warranty of merchantability or fitness for a particular purpose are voided when:
• The original purchaser or user ceases to own the product, or
• The fan is moved from its original point of installation.
This warranty is only valid within the 50 states of the United States and the District of Columbia. No other written or oral warranties apply, and no employee, agent, dealer or other person is authorized to give any warranties on behalf of Emerson Company.
REPAIR, REPLACEMENT OR A REFUND ARE THE EXCLUSIVE REMEDIES AVAILABLE UNDER THIS WARRANTY AND EMERSON IS NOT RESPONSIBLE FOR DAMAGES OF ANY KIND, INCLUDING INCIDENTAL AND CONSEQUENTIAL DAMAGES. Incidental damages include but are not limited to such damages as loss of time and loss of use. Consequential damages include but are not limited to the cost of repairing or replacing other property which was damaged if this product does not work properly.
How State Law Relates To The Warranty:
Some states do not allow the exclusion or limitation of incidental or consequential damages so the above exclusion or limitation may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
Air Comfort Products
DIVISION OF EMERSON COMPANY