EMERSON AIF12W300 User Manual

Embedded Power for Business-Critical Continuity
AIF12W300
600 Watts
Special Features
• 600 W continuous power at 100 °C baseplate temperature
• 108 W/in
(6.6W/cm3)
• High efficiency - up to 90%
• Low output ripple and noise
• Positive and Negative enable function
• Excellent transient response
• OVP, OCP, V Adj control with ALP
TM
• Paralleable with accurate current sharing
Total Power: 600 Watts
(48 V@12.5 Amps)
Input Voltage: 300 V # of Outputs: Single
Electrical Specifications
Safety
Input
Input ra nge: 250 - 420 Vdc Input surge: 500 V / 100 ms Efficiency: 90% typical
Output
Load regulation: 400 mV typical down to no load Line regulation: 200 mV typical Noise / ripple: 480 mV typical Transient response: 5% max deviation with 25% to 75% full load, slew = 1 A / uS Current share accuracy: 3% typical, 5% max (≥80% of Io max)
Overvoltage protection: 125% ± 5% Vo (nominal) - latch up Current limit: 105% - 120% Io maximum - hiccup
Short-circuit protection: 150% maximum - hiccup
Control
Voltage Adjust*: 80 to 120% Vo linear programming (see page 2 graph) Enable: TTL compatible (positive & negative enable options)
Current limit ddjust: 20 to 100% Io linear programming Clock input (external sync): 3.3 to 5.5 Vp-p @ 800 KHz ±10% Clock output (internal clock): 4.5 Vp-p typical@ 800 KHz ±5% Power good identification: High (Vo) = power good Temperature monitor output: 10 mV/°K (2.73 = 0 °C) Current monitor output: 0 to 1 mA (1 mA = 100% I
o rated
) ± 0.1 mA
Overvoltage protection adjust:
120 to 150% Vo
Auxiliary power: 12 V ± 1.5 V, 10 mA
UL: 60950 Recognized cUL: 60950 Recognized TUV: EN60950 Licensed
Rev. 06.11.08
AIF12W300
1 of 2
Embedded Power for Business-Critical Continuity
Mechanical Drawing
Operating temperature -20 °C to +100 °C
(case temperature)
Start up temperature -40 °C to +100 °C
(case temperature) Storage temperature -40 °C to +125 °C Overtemperature protection 110 °C max MTBF TBD hours
Environmental Specifications
Ordering Information
Input
Voltage
Output
Voltage
Efficiency Model Number Notes
300 V 48 V @ 12.5 A 90% (Typ) AIF12W300-L Positive Enable 300 V 48 V @ 12.5 A 90% (Typ) AIF12W300N-L Negative Enable Note:
1. For Non-thread hole, add suffix “-NT”.
Rev. 06.11.08
AIF12W300
2 of 2
Pin Assignments
Input Output Control Pins
31. Positive 21. Positive 1. Aux
32. Negative 22. Positive 2. Temp Mon
23. Positive 3. C Mon
24. Positive 4. C Share
25. Negative 5. Clk Out
26. Negative 6. Clk In
27. Negative 7. PG/ID
28. Negative 8. C Lim Adj/I2C CLK
9. OVP Adj/OCS
10. V Adj/I2C
11. Enable
12. -Sense
*Voltage Adjust
see chart on page 1
Americas
5810 Van Allen Way Carlsbad, CA 92008 USA Telephone: +1 (760) 930 4600 Facsimile: +1 (760) 930 0698
Europe (UK)
Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX United Kingdom Telephone: +44 (0) 1384 842 211 Facsimile: +44 (0) 1384 843 355
Asia (HK)
14/F, Lu Plaza 2 Wing Yip Street Kwun Tong, Kowloon Hong Kong Telephone: +852 2176 3333 Facsimile: +852 2176 3888
For global contact, visit:
www.powerconversion.com
techsupport.embeddedpower @emerson.com
While every precaution has been taken to ensure accuracy and completeness in this literature, Emerson Network Power assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions.
Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. ©2008 Emerson Electric Co.
EmersonNetworkPower. com
Embedded Computing
Embedded Power
Monitoring
Outside Plant
Power Switching & Controls Precision Cooling Racks & Integrated Cabinets
Services
Surge Protection
Emerson Network Power.
The global leader in enabling business-critical continuity.
AC Power
Connectivity
DC Power
120%
% V
O IOM
100%
80%
250
305
V I
420
Loading...