EMERSON AIF120Y300, AIF120F300, AIF80A300, AIF50B300, AIF40C300 User Manual

...
Embedded Power for Business-Critical Continuity
AIF Series
600 Watts
Special Features
• 600W Continuous power at 100°C baseplate temperature
• 108W/in
(6.6W/cm3)
• High efficiency - up to 90%
• Low output ripple and noise
• Positive and Negative enable function
• Excellent transient response
• OVP, OCP, V Adj control with ALP
TM
analog mode linear
control, or through I
C bus
with digital mode control.
• Paralleable with accurate current sharing
• EU Directive 2002/95/EC compliant for RoHS
Total Power: 600 Watts
(12V@50Amps) Input Voltage: 300V # of Outputs: Single
Electrical Specifications
Safety
Input
Input ra nge 250 - 420 VDC Input surge 450V / 100ms Efficiency 90%@5.0V (Typical)
Output
Load Regulation 0.2% typical down to no load Line Regulation 0.2% typical Noise / Ripple 100mV typical (below 5V); 2% typical (5V and above) Remote sense
Up to 0.5V
Output voltage adjust range
+/-20% for 5V and above; +10%/ -50% for below 5V
Transient Response
5% max for 3.3V and above, 150mV for 1.8V, deviation with 25% to 75% full load 250 μS (max) recovery
Current Share Accuracy 3% typical Overvoltage Protection 115% Vo (nominal) Current Limit 115% Io maximum
Control
Voltage Adjust 80 to 120% Vo linear programming for 12V, 15V, 24V, 48V 50%
to 110% for 1.8V - 5.0V
Enable TTL compatible (positive & negative enable options) Current Limit Adjust 20 to 100% Io linear programming or digital mode control Clock Input (external sync) 3.3 to 5.5Vp-p @ 800KHz ±10% Clock Output (internal clock) 4.5Vp-p typical@ 800KHz ±5% Power Good Identification High (Vo) = power good Temperature Monitor Output 10mV/°K (2.73 = 0°C) Current Monitor Output 0 to 1mA (1mA = 100% I
o rated
)
Over Voltage Protection Adjust
110 to 150% Vo linear programming by voltage or resistor, or digital mode control
Notes
Nominal values apply with sense pins connected and other control pin unconnected. ALP: Astec Linear Programming
UL 60950 Recognized cUL 60950 Recognized TUV EN60950 Licensed CE CE Mark
Rev. 05.23.07
AIF Series
1 of 2
RoHS
Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. ©2005 Emerson Electric Co.
Embedded Power for Business-Critical Continuity
Emerson Network Power.
The global leader in enabling business-critical continuity.
EmersonNetworkPower. com
AC Power
Connectivity
DC Power
Embedded Power
Inbound Power Integrated Cabinet Solutions Outside Plant
Precision Cooling
Site Monitoring and Services
Pin Assignments
Input (AC) Output (DC) Control Pins
31. Positive 21. Positive 1. +Sense
32. Negative 22. Positive 2. Temp Mon
23. Positive 3. C Mon
24. Positive 4. C Share
25. Negative 5. Clk Out
26. Negative 6. Clk In
27. Negative 7. PG/ID
28. Negative 8. C Lim Adj
9. OVP Adj
10. V Adj
11. Enable
12. -Sense
Mechanical Drawing
Americas
5810 Van Allen Way Carlsbad, CA 92008 USA Telephone: +1 760 930 4600 Facsimile: +1 760 930 0698
Europe (UK)
Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX United Kingdom Telephone: +44 (0) 1384 842 211 Facsimile: +44 (0) 1384 843 355
Asia (HK)
16th - 17th Floors, Lu Plaza 2 Wing Yip Street, Kwun Tong Kowloon, Hong Kong Telephone: +852 2176 3333 Facsimile: +852 2176 3888
For global contact, visit:
www.astecpower.com www.artesyn.com technicalsupport@astec.com technicalsupport@artesyn.com
While every precaution has been taken to ensure accuracy and completeness in this literature, Emerson Network Power assumes no responsibility, and dis­claims all liability for damages resulting from use of this information or for any errors or omissions.
Operating temperature -20°C to +100°C (case temperature) Start up temperature -40°C to +100°C (case temperature)
Storage temperature -40°C to +125°C Overtemperature protection 110°C max
Environmental Specifications
Ordering Information
Input Voltage Output Voltage Efficiency Model Number
300V 1.8V @ 120A 80% (Typ) AIF120Y300 300V 3.3V @ 120A 87% (Typ) AIF120F300 300V 5.0V @ 80A 90% (Typ) AIF80A300 300V 12V @ 50A 90% (Typ) AIF50B300 300V 15V @ 40A 90% (Typ) AIF40C300 300V 24V @ 25A 90% (Typ) AIF25H300
1. For Negative enable, add suffix “-N”.
2. For Non-thread hole, add suffix “-NT”.
3. For RoHS 6, add suffix “-L”. Default is RoHS 5.
Rev. 05.23.07
AIF Series
2 of 2