Rev. 01.31.08
AD8024N3L-001
1 of 2
Embedded Power for
Business-Critical Continuity
AD8024N3L-001
78 Watts
Special Features
• CE Mark EMC & LVD
• Universal AC input
• Fully regulated output
• Overcurrent, Overvoltage and
Thermal protection
• Constant voltage
• High efficiency
• High MTBF
• IEC320 AC receptacle, 3 pin
(type C14)
• Built in EMI filter
• (CISPR 22 Class B)
• AC Input fuse
• Complies with One Watt Input
Energy Star / Blue Angel
Requirement
Total Power: 78 Watts
Input Voltage: 90 - 264 Vac
# of Outputs: Single
Electrical Specifications
Safety
Input
Input ra nge: 90-264 Vac (wide range)
Frequency: 47-63 Hz
Input current: 2 A maximum
Efficiency: 84% typical
EMI/RFI: FCC Part 15, Subpart B Class B & EN55022 (CISPR 22) Class B
Safety ground
leakage current:
0.5 mA maximum@ 50/60 Hz, 264 Vac input
Output
Maximum Power (Po): 78 W
Hold-up time:
10 ms. minimum at full load @ 115 Vac
Overcurrent protection:
Output short circuit protection auto recover
Overload protection @ 110 - 120% above maximum rating
Thermal protection: Internally protected; output will latch off
Cable/connector: DC cable length 2.5 mm center plug
DC plug center +v
DC plug outer -v
UL: UL 60950-1
CSA: CSA-C22.2 no.60950-1
NEMKO: EN/IEC60950-1
CB: Certificate and report
Operating temperature:
0° to +40°C ambient
Storage temperature: -40°C to +70°C
Electromagnetic
susceptibility:
Designed to meet EN61000-4-2, -3, -4, level 2;
EN61000-4-5, Level 4; EN61000-3-3
Humidity: Operating; non-condensing 5% to 90% RH
MTBF demonstrated: >300,000 hours at full load and 25°C ambient conditions
Environmental Specifications
RoHS

Rev. 01.31.08
AD8024N3L-001
2 of 2
Embedded Power for
Business-Critical Continuity
Mechanical Drawing
Americas
5810 Van Allen Way
Carlsbad, CA 92008
USA
Telephone: +1 (760) 930 4600
Facsimile: +1 (760) 930 0698
Europe (UK)
Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX
United Kingdom
Telephone: +44 (0) 1384 842 211
Facsimile: +44 (0) 1384 843 355
Asia (HK)
14/F, Lu Plaza
2 Wing Yip Street
Kwun Tong, Kowloon
Hong Kong
Telephone: +852 2176 3333
Facsimile: +852 2176 3888
For global contact, visit:
www.powerconversion.com
technicalsupport@
powerconversion.com
While every precaution has been taken to ensure
accuracy and completeness in this literature, Emerson
Network Power assumes no responsibility, and disclaims
all liability for damages resulting from use of this
information or for any errors or omissions.
Ordering Information
Model
Number
Maximum
Power
Output
Voltage
Maximum
Load
Peak Load1Regulation
2
Ripple
P/P (PARD)
3
AD8024N3L-001
80 W 24 Vdc 3.25 A 4.16 A ±5% <400mV
1. Peak current lasting <4 seconds with a maximum 10% duty cycle.
2. At 25ºC including initial tolerance, line voltage, load currents and output voltages adjusted to factory
settings.
3. Peak-to-peak with 20MHz bandwidth and 10μF (tantalum capacitor) in parallel with a 0.1μF capacitor at rated
line voltage and load ranges.
5.87”
(149.0)
3.13”
79.6
1.76”
44.6
REFER TO O/P CABLE DRAWING
MODEL LABEL
62”
(1575)
AC POWER ADAPTER
1.76" (H) x 3.13" (W) x 5.87" (L)
44.0 mm (H) x 79.6 mm (W) x 149.0 mm (L)
AC Input Connector: IEC320, C14
AC Input power cord sold separately
Notes:
1. Specifications subject to change without notice.
2. All dimensions in inches (mm), tolerance is ± 0.02" (±0.5 mm)
3. Warranty: 2 year
4. Weight: 0.91 lb./ 0.41 kg
5. AC input power cord sold separately.
6. Specifications at factory settings at 115VAC input,
25 °C unless otherwise stated
Emerson Network Power and the Emerson
Network Power logo are trademarks and
service marks of Emerson Electric Co.
©2008 Emerson Electric Co.
EmersonNetworkPower. com
Embedded Computing
Embedded Power
Monitoring
Outside Plant
Power Switching & Controls
Precision Cooling
Racks & Integrated Cabinets
Services
Surge Protection
Emerson Network Power.
The global leader in enabling
business-critical continuity.
AC Power
Connectivity
DC Power