EMERSON AD50 User Manual

Rev. 03.19.08
AD50 Series
1 of 2
Embedded Power for Business-Critical Continuity
AD50 Series
50 Watts
Special Features
• Fully regulated output
• EN61000-3-2 compliant
• Input power <74 watts
• Overcurrent and overvoltage protection
• High efficiency
• High MTBF
• IEC320 AC input receptacle
3 pin (type C6) - AD5012N3L 2 pin (type C8) - AD5012N2L
• Built in EMI filter
• (CISPR 22 Class B)
• AC input fuse
• Complies with One Watt Input Energy Star / Blue Angel Requirement
• CE Mark EMC & LVD
Total Power: 50 Watts Input Voltage: 90 - 264 VAC # of Outputs: single
Electrical Specifications
Safety
Input
Input ra nge 90-264 Vac (wide range) Frequency 47-63 Hz Inrush current 60A maximum @ 230VAC, cold start 25C°
Input current 2 A maximum Efficiency 80% typical EMI/RFI FCC Part 15, Class B & EN55022 (CISPR 22) Class B Safety ground
leakage current
300μA maximum@ 50/60 Hz, 264 VAC input - AD5012N3L 100μA maximum@ 50/60 Hz, 264 VAC input - AD5012N2L
Output
Maximum Power (Po)
50 W
Hold-up time
17 ms. minimum at full load @ 100 Vac, 47 Hz
Overvoltage protection
16 - 20 V Latching type, recycle AC to reset.
Overcurrent protection
Output short circuit protection auto recover Overload protection @ 110 - 120% above maximum rating
Thermal protection
105° to 120°C Trip point; output will latch off
Cable/connector
DC cable length 2.5 mm center plug DC plug center +v DC plug outer -v
CSA
UL
UL 60950-1
CSA CSA-C22.2 no.60950-1 VDE EN/IEC60950-1 CE Mark LVD and EMC
Operating temperature:
5° to +40°C ambient
Storage temperature: -40°C to +70°C Electromagnetic susceptibility:
Designed to meet EN61000-4-2, -4, -5, level 4; EN61000-4-3, -6, 10v/m; EN61000-4-8, -11; EN61000-3-3 and EN61000-3-2 Class A
Humidity: Operating; non-condensing 10% to 90% RH
MTBF demonstrated: >300,000 hours at full load and 25°C ambient conditions
Environmental Specifications
RoHS
Rev. 03.19.08
AD50 Series
2 of 2
Embedded Power for Business-Critical Continuity
Mechanical Drawing
Ordering Information
Model
Number
Maximum
Power
Output
Voltage
Maximum
Load
Peak Load1Regulation
2
Ripple
P/P (PARD)
3
AD5012N3L
50 W 12 Vdc 4.16 A 6 A ±5% <500 mV
AD5012N2L
50 W 12 Vdc 4.16 A 6 A ±5% <500 mV
1. Peak current lasting 200ms every 3 seconds.
2. At 25ºC including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings.
3. Peak-to-peak with 20MHz bandwidth and 10μF (tantalum capacitor) in parallel with a 0.1μF capacitor at rated line voltage and load ranges.
1.61˝
(41)
4.72˝ (120)
48˝
(1219 ±20)
0.4˝
(10.5)
Notes:
1. Specifications subject to change without notice.
2. All dimensions in inches (mm), tolerance is
± 0.02" (±0.5mm)
3. Warranty: 2 year
4. Weight: 0.61 lb./ 0.28 kg
5. AC input power cord sold separately.
6. Specifications at factory settings at 115VAC input, 25°C unless otherwise stated
7. AC Input Connector: IEC320, C6 or C8
2.56˝
(65)
C8
C6
Americas
5810 Van Allen Way Carlsbad, CA 92008 USA Telephone: +1 (760) 930 4600 Facsimile: +1 (760) 930 0698
Europe (UK)
Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX United Kingdom Telephone: +44 (0) 1384 842 211 Facsimile: +44 (0) 1384 843 355
Asia (HK)
14/F, Lu Plaza 2 Wing Yip Street Kwun Tong, Kowloon Hong Kong Telephone: +852 2176 3333 Facsimile: +852 2176 3888
For global contact, visit:
www.powerconversion.com
techsupport.embeddedpower @emerson.com
While every precaution has been taken to ensure accuracy and completeness in this literature, Emerson Network Power assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions.
Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. ©2008 Emerson Electric Co.
EmersonNetworkPower. com
Embedded Computing
Embedded Power
Monitoring
Outside Plant
Power Switching & Controls Precision Cooling Racks & Integrated Cabinets
Services
Surge Protection
Emerson Network Power.
The global leader in enabling business-critical continuity.
AC Power
Connectivity
DC Power
Loading...