Emerson 1HDEZ-1521 User Manual

TROUBLESHOOTING
Emerson Inspire
1HDEZ-1521
Installation Instructions
Thermostat/Interface
Equipment Control
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE
WARNING
!
CAUTION
!
INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE.
To prevent electrical shock and/or equipment damage, disconnect electric power to system at main fuse or circuit breaker box until installation is complete.
Thermostat installation and all components of the control system shall conform to Class II circuits per the NEC code.
ATTENTION: MERCURY NOTICE
This product does not contain mercury. However, this product may replace a product that contains mercury.
Mercury and products containing mercury must not be discarded in household trash. Do not touch any spilled mercury. Wearing non-absorbent gloves, clean up any spilled mercury and place in a sealed container. For proper disposal of a product containing mercury or a sealed container of spilled mercury, place it in a suitable shipping container. Refer to www.
thermostat-recycle.org for location to send product containing mercury.
Index Page
Applications and Specications
Installation Advanced Installer Menu Main Menu Troubleshooting
3
4 12 20 26
Applications and Speci cations
Con guration
Options
Single Stage Gas, Oil, Electric, Heat Only, Cool Only or
Heat Cool Systems
Multi Stage Gas, Oil, Electric, Heat Only, Cool Only or
Heat Cool Systems
Heat Pump Single or Two Compressor Systems with up
to 2 Stages of Aux / Em Heat
Heat Pump
with Dual Fuel
Single or Two Compressor Systems with up to 2 Stages of Fossil fuel Heat
Applications Maximum
Stages
1/1
2/2
4/2
4/2
Electrical Rating:
Input-Hardwire .............................. 20 to 30 VAC
Terminal Load ............................... 1.0A per terminal, 2.5A maximum
all terminals combined
Setpoint Range ............................. 45° to 99°F (7° to 37°C)
Di erential (Single Stage) ............. Heat 0.6°F; Cool 1.2°F
Di erential (Multi-Stage) .............. Heat 0.6°F; Cool 1.2°F
Di erential (Heat Pump) ............... Heat 1.2°F; Cool 1.2°F
Operating Ambient ....................... 32°F to +105°F (0° to +41°C)
Operating Humidity ...................... 90% non-condensing max.
Shipping Temperature Range ........ -40° to +150°F (-40° to +65°C)
Dimensions Interface .................... 3-1/4"H x 6-1/8"W x 5/8"D
Dimensions Control ....................... 5-1/2"H x 5-3/4"W x 1-1/2"D
APPLICATIONS
& SPECIFICATIONS
Installation
Reduce installation time with a USB
1. Go to www.white-rodgers.com
2. Enter 1HDEZ-1521 in the Model
Number Search  eld
3. Select the link for the USB download
INSTALLATION
tool and follow instructions
Upload pre-con gured thermostat
settings for every job!
Create custom messages for your rou­tine maintenance and service calls!
INSTALLATION
Retur
Installation
Equipment Control
Mount on wall or exterior surface of HVAC equipment. Control has four mounting holes. Wall anchors and screws are provided for mounting on dry­wall. Drill 3/16" hole for drywall mounting.
If mounting on equipment Do Not Mount inside HVAC equipment. Only mount on outside of HVAC equipment.
n Air Duct
Supply
Duct
Equipment Control
Module
Gas Furnace Equipment
INSTALLATION
Installation
Equipment Control Terminals Operation / Function
R ................................................ 24 VAC Transformer
RC .............................................. 24 VAC Cooling Transformer*
RH ............................................. 24 VAC Heating Transformer*
C ................................................ 24 V Transformer Common
W/E ............................................ Heating Stage 1 HP Aux/Em Heat Stage 1
W2 ............................................. Heating Stage 2 HP Aux/Em Heat Stage 2
Y ................................................ Compressor Stage 1
Y2 .............................................. Compressor Stage 2
G ................................................ Fan Relay
L Terminal .................................. System Monitor Compatible with
Comfort Alert Diagnostics
O/B Terminal .............................. Changeover Relay Heat Pump
DHM .......................................... Dehumidication Relay / Connection
DHM2 ........................................ Dehumidication Relay / Connection
HM ............................................. Humidication Relay / Connection
HM2 ........................................... Humidication Relay / Connection
R ................................................ 24 VAC to Interface
1 ................................................. Data to/from Interface
2 ................................................. Data to/from Interface
C ................................................ 24 VAC Common to Interface
RJ11 ........................................... Field conguration hook-up with RJ11
equipped conguration tool
+ ................................................. Voltage to Outdoor Sensor
S ................................................ Outdoor Sensor Temperature Signal
- ................................................. Voltage to Outdoor Sensor
*For 2 transformer systems, cut and tape o one transformer. If transformer
safety circuits are only in one of the systems, remove the transformer of the system with NO safety circuits. If required, replace remaining transformer with a 75 VA Class II transformer. After disconnecting one transformer, the two commons must be jumpered together.
INSTALLATION
LED push
Installation
button switch
Wiring to indoor/outdoor equipment
Wiring to
Sensor
R and C from HVAC
terminal strip or
system transformer
+ S
-
R RC RH
C
W/E
O/B
HM
HM2
W2
Y
Y2
G
L
Wiring to humidification equipment
Status/Fault
7-Segment LED
Wiring to
Thermostat
Configuration Plug-In tool
R
1 2
C
RJ-11 Connection for
DHM switch*
HM switch*
DHM
DHM2
Wiring to dehumidification equipment
* To use the HVAC transformer to power humidication/dehumidication
switch HM/DHM switches to “SYS” position:
– Connect humidier to HM – Connect dehumidier to DHM If humidier or dehumidier have a separate transformer, switch HM or
DHM switch to “DRY” position:
– Connect humidier to HM and HM2 (or) – Connect dehumidier to DHM and DHM2
INSTALLATION
Installation
Fig. 1 - Typical Connection of a Single Stage or Multi-Stage System
*
SYSTEM R RH RC C W/E
Heat N/A Cool N/A Fan N/A System
24 VAC
Common
Heat
Required
mode
Single
Stage
Multi
Stage
24 VAC
Power
24 VAC
Power
24 VAC
Power for
Heating
24 VAC
Power
24 VAC
Power
for Cooling
24 VAC
Power
stage
*Factory installed jumper between RH and RC
Fig. 2 - Typical Connection of Heat Pump System up to 4 Stages Heat/2 Stages Cool
*
SYSTEM R RH RC C W/E
Heat
24 VAC
24 VAC
Pump
Power
Power for
Heating
24 VAC
Power
for Cooling
*Factory installed jumper between RH and RC Note: Dual fuel systems W/E is fossil fuel 1
24 VAC
Common
Required
Aux /
Em
1
Stage
Y
1
Y
1
sor
st
st
mode
stage
Stage
-
G O/B L
Y2
Cool
nd
2
G O/B L
Y2
nd
Fan Change
2
Com
-
pres-
sor
over
Valve
W2
Heat
Cool
mode
mode
st
nd
1
2
stage
stage
W2
Aux /
Em
Stage
st
nd
2
Com
Stage
pres-
st
stage and W2 is fossil fuel 2nd stage.
Monitor
-
NEUTRAL
24 VAC
HOT
System
Monitor
NEUTRAL
24 VAC
CLASS II
Transformer
HOT
Transformer
120 VAC
120 VAC
CLASS II
INSTALLATION
Installation
Wiring Guide for Equipment Accessories
Fig. 3 - Humidier. HM terminal provides system 24V on call for humidication
RH
HM DRY
HM2
HM
HM2
Non-Powered Humidier
R
C
Transformer
Fig. 4 - Powered Humidier. With HM DRY switch in HM2 position, HM and HM2 provide normally open dry contact for low voltage (24V) powered
humidier connection.
RH
HM DRY
HM2
HM
HM2
Non-Powered Humidier
Fig. 5 - Powered Dehumidier. With DHM DRY switch in DHM2 position, DHM and DHM2 provide normally open dry contact for low voltage (24V)
whole house powered dehumidier connection.
RH
DHM DRY
DHM2
DHM
DHM2
Powered Dehumidier
INSTALLATION
Installation
Wiring Guide for Equipment Accessories
Fig. 6 - System Dehumidication with variable speed blower. For systems where low speed requires connect to normally open 24V powered DHM terminal for low speed connection on air handler/furnace (24V removed
on dehumidication call).
RH
DHM DRY
DHM2
Fig. 7 - System Dehumidication with variable speed blower. For systems where low speed requires system 24V on dehumidification connect 24V to DHM2 with DHM DRY switch in DHM2 position and connect DHM to low speed connection on air handler/ furnace.
DHM
DHM2
Low Speed Fan
Transformer
10
R
RH
C
DHM DRY
DHM2
DHM
DHM2
Low Speed Fan