FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE
WARNING
!
CAUTION
!
INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL
INJURY AND/OR PROPERTY DAMAGE.
To prevent electrical shock and/or equipment damage, disconnect
electric power to system at main fuse or circuit breaker box until
installation is complete.
Thermostat installation and all components of the control system shall
conform to Class II circuits per the NEC code.
ATTENTION: MERCURY NOTICE
This product does not contain mercury. However, this product may replace
a product that contains mercury.
Mercury and products containing mercury must not be discarded in
household trash. Do not touch any spilled mercury. Wearing non-absorbent
gloves, clean up any spilled mercury and place in a sealed container. For
proper disposal of a product containing mercury or a sealed container of
spilled mercury, place it in a suitable shipping container. Refer to www.
thermostat-recycle.org for location to send product containing mercury.
IndexPage
Applications and Specications
Installation
Advanced Installer Menu
Main Menu
Troubleshooting
3
4
12
20
26
2
Applications and Speci cations
Con guration
Options
Single StageGas, Oil, Electric, Heat Only, Cool Only or
Heat Cool Systems
Multi StageGas, Oil, Electric, Heat Only, Cool Only or
Heat Cool Systems
Heat Pump Single or Two Compressor Systems with up
to 2 Stages of Aux / Em Heat
Heat Pump
with Dual Fuel
Single or Two Compressor Systems with up
to 2 Stages of Fossil fuel Heat
ApplicationsMaximum
Stages
1/1
2/2
4/2
4/2
Electrical Rating:
Input-Hardwire .............................. 20 to 30 VAC
Terminal Load ............................... 1.0A per terminal, 2.5A maximum
all terminals combined
Setpoint Range ............................. 45° to 99°F (7° to 37°C)
Shipping Temperature Range ........ -40° to +150°F (-40° to +65°C)
Dimensions Interface .................... 3-1/4"H x 6-1/8"W x 5/8"D
Dimensions Control ....................... 5-1/2"H x 5-3/4"W x 1-1/2"D
APPLICATIONS
& SPECIFICATIONS
3
Installation
Reduce installation time with a USB
1. Go to www.white-rodgers.com
2. Enter 1HDEZ-1521 in the Model
Number Search eld
3. Select the link for the USB download
INSTALLATION
tool and follow instructions
Upload pre-con gured thermostat
settings for every job!
Create custom messages for your routine maintenance and service calls!
4
INSTALLATION
Retur
Installation
Equipment Control
Mount on wall or exterior surface of HVAC equipment. Control has four
mounting holes. Wall anchors and screws are provided for mounting on drywall. Drill 3/16" hole for drywall mounting.
If mounting on equipment Do Not Mount inside HVAC equipment.
Only mount on outside of HVAC equipment.
n Air Duct
Supply
Duct
Equipment Control
Module
Gas Furnace Equipment
5
INSTALLATION
Installation
Equipment Control TerminalsOperation / Function
R ................................................ 24 VAC Transformer
R ................................................ 24 VAC to Interface
1 ................................................. Data to/from Interface
2 ................................................. Data to/from Interface
C ................................................ 24 VAC Common to Interface
RJ11 ........................................... Field conguration hook-up with RJ11
equipped conguration tool
+ ................................................. Voltage to Outdoor Sensor
S ................................................ Outdoor Sensor Temperature Signal
- ................................................. Voltage to Outdoor Sensor
*For 2 transformer systems, cut and tape o one transformer. If transformer
safety circuits are only in one of the systems, remove the transformer of the
system with NO safety circuits. If required, replace remaining transformer
with a 75 VA Class II transformer. After disconnecting one transformer, the
two commons must be jumpered together.
6
INSTALLATION
LED push
Installation
button switch
Wiring to
indoor/outdoor
equipment
Wiring to
Sensor
R and C from HVAC
terminal strip or
system transformer
+
S
-
R
RC
RH
C
W/E
O/B
HM
HM2
W2
Y
Y2
G
L
Wiring to
humidification
equipment
Status/Fault
7-Segment LED
Wiring to
Thermostat
Configuration Plug-In tool
R
1
2
C
RJ-11 Connection for
DHM switch*
HM switch*
DHM
DHM2
Wiring to
dehumidification
equipment
* To use the HVAC transformer to power humidication/dehumidication
switch HM/DHM switches to “SYS” position:
– Connect humidier to HM
– Connect dehumidier to DHM
If humidier or dehumidier have a separate transformer, switch HM or
DHM switch to “DRY” position:
– Connect humidier to HM and HM2 (or)
– Connect dehumidier to DHM and DHM2
7
INSTALLATION
Installation
Fig. 1 - Typical Connection of a Single Stage or Multi-Stage System
*
SYSTEM RRHRCCW/E
Heat N/A Cool N/A Fan N/A System
24 VAC
Common
Heat
Required
mode
Single
Stage
Multi
Stage
24 VAC
Power
24 VAC
Power
24 VAC
Power for
Heating
24 VAC
Power
24 VAC
Power
for Cooling
24 VAC
Power
stage
*Factory installed jumper between RH and RC
Fig. 2 - Typical Connection of Heat Pump System up to 4 Stages
Heat/2 Stages Cool
*
SYSTEM RRHRCCW/E
Heat
24 VAC
24 VAC
Pump
Power
Power for
Heating
24 VAC
Power
for Cooling
*Factory installed jumper between RH and RC
Note: Dual fuel systems W/E is fossil fuel 1
24 VAC
Common
Required
Aux /
Em
1
Stage
Y
1
Y
1
sor
st
st
mode
stage
Stage
-
G O/BL
Y2
Cool
nd
2
GO/BL
Y2
nd
Fan Change
2
Com
-
pres-
sor
over
Valve
W2
Heat
Cool
mode
mode
st
nd
1
2
stage
stage
W2
Aux /
Em
Stage
st
nd
2
Com
Stage
pres-
st
stage and W2 is fossil fuel 2nd stage.
Monitor
-
NEUTRAL
24 VAC
HOT
System
Monitor
NEUTRAL
24 VAC
CLASS II
Transformer
HOT
Transformer
120 VAC
120 VAC
CLASS II
8
INSTALLATION
Installation
Wiring Guide for Equipment Accessories
Fig. 3 - Humidier. HM terminal provides system 24V on call for humidication
RH
HM DRY
HM2
HM
HM2
Non-Powered
Humidier
R
C
Transformer
Fig. 4 - Powered Humidier. With HM DRY switch in HM2 position, HM
and HM2 provide normally open dry contact for low voltage (24V) powered
humidier connection.
RH
HM DRY
HM2
HM
HM2
Non-Powered
Humidier
Fig. 5 - Powered Dehumidier. With DHM DRY switch in DHM2 position,
DHM and DHM2 provide normally open dry contact for low voltage (24V)
whole house powered dehumidier connection.
RH
DHM DRY
DHM2
DHM
DHM2
Powered
Dehumidier
9
INSTALLATION
Installation
Wiring Guide for Equipment Accessories
Fig. 6 - System Dehumidication with variable speed blower. For systems
where low speed requires connect to normally open 24V powered DHM
terminal for low speed connection on air handler/furnace (24V removed
on dehumidication call).
RH
DHM DRY
DHM2
Fig. 7 - System Dehumidication with variable speed blower. For systems
where low speed requires system 24V on dehumidification connect 24V
to DHM2 with DHM DRY switch in DHM2 position and connect DHM
to low speed connection on air handler/ furnace.
DHM
DHM2
Low Speed
Fan
Transformer
10
R
RH
C
DHM DRY
DHM2
DHM
DHM2
Low Speed
Fan