HRC2-10-2C
Installation Instructions
Refrigeration Packages
NOTE: It is important to insure proper ventilation. Allow a
minimum clearance of 6 inches (152 mm) in front and 3
inches (76mm) in the rear of the unit. If unit is to be inĀstalled in an enclosure, allow the following clearances
around unit 1 inch (25mm) each side, 3 inches (76mm) in
the rear, 3 inches (76mm) inches above wall.
This chiller has been designed for use with potable water
and includes an o-ring seal on the drain plug. This fitting
should be replaced if the unit is to be used with more
aggressive fluids.
LEGEND:
A = 3/8" O.D. TUBE WATER OUT
B = 3/8" O.D. TUBE WATER INLET
C = 3/8" O.D. TUBE TANK DRAIN
D = TEMPERATURE ADJUSTMENT
E = ELECTRICAL
97735C(4/01)
ITEM
NO.
1
2
3
4
5
6
7
8
9
10
11*
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
NS
ITEMIZED PARTS LIST
10 GPH
PART NO.
27666C
31513C
31430C
30664C
20282C
70018C
70009C
66305C
50189C
66203C
36021C
30262C
36019C
30233C
30235C
30234C
19037000
100806740570
66619C
27665C
70772C
27670C
27663C
27662C
27664C
27667C
35882C
27669C
27668C
Cover - Terminal Box
Control - Cold
Motor - Fan
Fan - Blade
Fan - Bracket
Fan - Nut
Screw - Motor Mounting
Condenser
Shroud
Drier
Compr. Serv Pak
Relay
Overload
Overload Spring
Cover - Terminal
Compr. Bale Strap
Clip
Grommet
Evaporator - Assy
Cover - Insulation Box
Drain Plug
Base Assy
Panel - Insul Box (Rear)
Panel - End
Box - Insulation (Front)
Terminal Box Assy
Control-Freeze Protect
Grille - Front
Grille - Rear (Not Shown)
HRC2-10-2C
DESCRIPTION
*INCLUDES RELAY & OVERLOAD. IF UNDER WARRANTY,
REPLACE WITH SAME COMPRESSOR USED IN ORIGINAL
ASSEMBLY.
NOTE: All correspondence pertaining to any of the
above water cooler or orders for repair MUST include
model number and serial number of cooler, name and
part number of replacement part.
NOTE: For use with photo processing applications,
adjust thermostat to warmer settings.
23
19
25
20
8,9
27
2
1
26
3, 4, 5, 6, 7
10
12,13, 14, 15, 16
24
28
97735C (4/01)