S P E C I F I CAT I O NS
ENERAL
G
Self-contained, wall hung electric refrigerated water cooler.
Capacity of 50°F drinking water, based upon 80°F inlet water
and 90°F ambient.
Non-pressurized tank system is standard. Non-pressurized
water tank is located after bubbler valve, so that tank is
subject to line pressure only when valve button is pressed.
O LEAD DESIGN
N
THIS WATER COOLER COMPLIES WITH THE LEAD-FREE
DEFINITION IN THE SAFE DRINKING WATER ACT OF 1986
AND LEAD CONTAMINATION CONTROL ACT OF 1988.
Elkay Water Coolers are manufactured with a waterway system utilizing copper components and completely lead-free
material. These waterways have no lead because all lead
materials, such as leaded brass, have been removed. All
joints are brazed using silver solder only. No lead solder is
permitted. A strainer with an easily cleanable screen is provided to allow trapping and convenient removal of water born
particulate of 140 microns and larger prior to their entry into
the water cooler.
CAPACITIES CHART
*GPH of 50°F Drinking Water
oom Temperature °F
odel Base
M
umber Rate 70°F 80°F 90°F Watts Amps Option Lbs.
N
HEW3 3.0 3.6 3.2 3.0 200 3.0 No 42
HEWD N/A —— — —— No 26
Note - Model HEWD does not include a cooling system.
*Based on 80°F inlet water temperature.
Rated watts shown are based on operational (run) time, in accordance with A.R.I.
Standard 1010 conditions. Specific applications will determine the actual watts
consumed per hour. Watts consumed will be based on number of people
served per hour (usage), ambient temperatures, and inlet water temperature.
R
COOLING SYSTEM
Motor Compressor: Hermetically sealed reciprocating type,
115V, 60 Hertz single phase. Sealed-in lifetime oil supply.
Equipped with electric cord and three prong molded rubber
plug.
Condenser: Fan cooled, copper tube with aluminum fins. Fan
motor is permanently lubricated.
Cooling Unit: Combination tube-tank type. Tube portion is
continuous coil of copper tubing. Fully insulated with EPS
foam which meets Underwriters Laboratories Inc. requirements for self-extinguishing material.
Refrigerant Control: Refrigerant HFC-134a is controlled by
accurately calibrated capillary tube for positively trouble free
operation.
Temperature Control: Enclosed adjustable thermostat is factory pre-set. Requires no adjustement other than for altitude
requirements. Easily accessible.
ull Glass Ship.
F
ated Load Filler Wt.
R
No Lead Wall Mount Compact
Slant Front Water Cooler
Models HEW3 and HEWD
odel HEW3
M
CONSTRUCTION
Cooler Top: One piece stainless steel basin, smoothly
contoured and deep, polished to a uniform Elkay bright luster
finish. Snap-out strainer for ease of cleaning vertical drain,
without removing cooler top.
Cabinet: Cabinet is one piece wrap around. Removable for
access to interior through front and sides.
Color: Models available in Light Gray Granite, Almond,
Sandalwood and Stainless Steel panels.
Exclusive Flexi-Guard
utilizes a pliable polyester elastomer to prevent accidental
mouth injuries. Flexes on impact and then returns to original
position. Strong. Abrasion-resistant. Anti-sweat. Meets UL
requirements, and all sanitary codes. Keyed in location to prevent rotation. Patented** valve and in-line flow regulator provides constant stream from 20 to 105 psi.
Protected by Elkay’s 5 Year Limited Warranty on the refrigeration system of the unit.
Elkay Electric Air Cooled Water Coolers are listed by
Underwriters Laboratories Inc., approved by C.S.A., rated in
accordance with A.R.I. Standard 1010 and meet all known
federal and state plumbing codes.
STANDARDS
Elkay Electric Air Cooled Water Coolers are listed
by Underwriters Laboratories Inc. and comply with
both Canadian and U.S. requirements.
These units comply with A.R.I. Standard 1010.
This cooler is certified by WQA to lead-free compliance including
NSF/ANSI 61-ANNEX G, AB 1953.
®
Safety Bubbler: Innovative design
In keeping with our policy of continuing product improvement, Elkay reserves the right to change
product specifications without notice. Please visit elkayusa.com for most current version of Elkay
product specification sheets.
Elkay
elkayusa.com
2222 Camden Court
Oak Brook, IL 60523
This specification describes an Elkay product with design, quality and functional benefits to the
user. When making a comparison of other producers’ offerings, be certain these features are not
overlooked.
Printed in U.S.A.
©2011 Elkay
(Rev. 4/11) 10-11H
OPEN AREA FOR
PLUMBING
CONNECTIONS
WALL MOUNTING HANGER
(FURNISHED)
OPTIONAL
ELECTRICAL
OUTLET
LOCATION
FLOOR LINE
40"
(1016mm)
1-3/4"
(44mm)
11-3/4"
(298mm)
5-1/2"
(140mm)
1-1/2 FOOT (457mm) LONG
POWER CORD
1-1/4" (32mm) O.D.
TAILPIECE
(TRAP NOT
FURNISHED)
13"
(330mm)
3"
(76mm)
C
L
4-1/2"
(114mm)
4-1/4"
(108mm)
4-1/4"
(108mm)
15"
(381mm)
14"
(356mm)
12-3/4"
(324mm)
15-3/4"
(400mm)
2-3/4"
(70mm)
2"
(51mm)
2"
(51mm)
6-1/2"
(165mm)
RECOMMENDED LOCATION
ELECTRICAL OUTLET
(BY OTHERS)
RECOMMENDED LOCATION
3/8" I.P.S. COLD WATER SUPPLY
(STUB OUT FROM WALL 1" [25mm])
WASTE OUTLET – 1-1/4" I.P.S.
(STUB OUT FROM WALL 1" [25mm])
Roughing-In Dimensions
Installation – A steel mounting hanger provides rigid support of the cooler on the wall. Install
at normal bubbler height of approximately 40" (1016mm), or at a lower height for children. If
recessed in an alcove, allow full opening beneath cooler, and at least 4" (102mm) or more on
each side for air circulation.
FRONT VIEW SIDE VIEW
N
OTE: WATERFLOW
D
IRECTION
S
ERVICE STOP
(
NOT FURNISHED)
3
/8" O.D. TUBE CONNECT
C
OLD WATER SUPPLY
1/4" O.D. TUBE
WATER INLET
TO COOLER
B
UILDING WATER
I
NLET
N
OTE: WATERFLOW
D
IRECTION
S
ERVICE STOP
(
NOT FURNISHED)
3
/8" O.D. TUBE CONNECT
C
OLD WATER SUPPLY
1/4" O.D. TUBE
WATER INLET
TO COOLER
B
UILDING WATER
I
NLET
OPERATION OF QUICK CONNECT FITTINGS
S
IMPLY PUSH IN
TUBE TO ATTACH
T
UBE IS SECURED
IN POSITION
P
USH IN COLLET
TO RELEASE TUBE
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
R
ELEASE TUBE
AB
C
OPERATION OF QUICK CONNECT FITTINGS
S
IMPLY PUSH IN
TUBE TO ATTACH
T
UBE IS SECURED
IN POSITION
P
USH IN COLLET
TO RELEASE TUBE
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
R
ELEASE TUBE
AB
C
No Lead Wall Mount Compact
Slant Front Water Cooler
Models HEW3 and HEWD
RO U G H - I N D I M E N S I O N S
MPORTANT!
I
NSTALLER PLEASE NOTE:
This water cooler has been designed and built to provide water to the user which has
not been altered by materials in the cooler waterways.
The grounding of electrical equipment such as telephone, computers, etc., to water
lines is a common procedure. This grounding may be in the building but may also
occur away from the building. This grounding can cause electrical feedback into a
water cooler creating an electrolysis which creates a metallic taste or causes an
increase in the metal content of the water. This condition is avoidable by installing the
cooler using the proper materials as shown below.
his water cooler must be connected to the water supply using a dielectric coupling.
T
he cooler is furnished with a non-metallic strainer which meets this requirement.
T
he drain trap which is provided by the installer should also be plastic to completely
T
solate the cooler from the building plumbing system.
i
I
NOTICE
Elkay
10-11H (Rev. 4/11)
2222 Camden Court
Oak Brook, IL 60523
Printed in U.S.A.
©2011 Elkay