Elkay HEW3 User Manual

®
S P E C I F I CAT I O NS
ENERAL
G
Self-contained, wall hung electric refrigerated water cooler. Capacity of 50°F drinking water, based upon 80°F inlet water and 90°F ambient.
Non-pressurized tank system is standard. Non-pressurized water tank is located after bubbler valve, so that tank is subject to line pressure only when valve button is pressed.
N
THIS WATER COOLER COMPLIES WITH THE LEAD-FREE DEFINITION IN THE SAFE DRINKING WATER ACT OF 1986 AND LEAD CONTAMINATION CONTROL ACT OF 1988.
Elkay Water Coolers are manufactured with a waterway sys­tem utilizing copper components and completely lead-free material. These waterways have no lead because all lead materials, such as leaded brass, have been removed. All joints are brazed using silver solder only. No lead solder is permitted. A strainer with an easily cleanable screen is pro­vided to allow trapping and convenient removal of water born particulate of 140 microns and larger prior to their entry into the water cooler.
CAPACITIES CHART
*GPH of 50°F Drinking Water
oom Temperature °F
odel Base
M
umber Rate 70°F 80°F 90°F Watts Amps Option Lbs.
N
HEW3 3.0 3.6 3.2 3.0 200 3.0 No 42
HEWD N/A —— — —— No 26
Note - Model HEWD does not include a cooling system.
*Based on 80°F inlet water temperature. Rated watts shown are based on operational (run) time, in accordance with A.R.I.
Standard 1010 conditions. Specific applications will determine the actual watts consumed per hour. Watts consumed will be based on number of people served per hour (usage), ambient temperatures, and inlet water temperature.
R
COOLING SYSTEM
Motor Compressor: Hermetically sealed reciprocating type, 115V, 60 Hertz single phase. Sealed-in lifetime oil supply. Equipped with electric cord and three prong molded rubber plug.
Condenser: Fan cooled, copper tube with aluminum fins. Fan motor is permanently lubricated.
Cooling Unit: Combination tube-tank type. Tube portion is continuous coil of copper tubing. Fully insulated with EPS foam which meets Underwriters Laboratories Inc. require­ments for self-extinguishing material.
Refrigerant Control: Refrigerant HFC-134a is controlled by accurately calibrated capillary tube for positively trouble free operation.
Temperature Control: Enclosed adjustable thermostat is fac­tory pre-set. Requires no adjustement other than for altitude requirements. Easily accessible.
ull Glass Ship.
F
ated Load Filler Wt.
R
No Lead Wall Mount Compact
Slant Front Water Cooler
Models HEW3 and HEWD
odel HEW3
M
CONSTRUCTION
Cooler Top: One piece stainless steel basin, smoothly contoured and deep, polished to a uniform Elkay bright luster finish. Snap-out strainer for ease of cleaning vertical drain, without removing cooler top.
Cabinet: Cabinet is one piece wrap around. Removable for access to interior through front and sides.
Color: Models available in Light Gray Granite, Almond, Sandalwood and Stainless Steel panels.
Exclusive Flexi-Guard
utilizes a pliable polyester elastomer to prevent accidental mouth injuries. Flexes on impact and then returns to original position. Strong. Abrasion-resistant. Anti-sweat. Meets UL requirements, and all sanitary codes. Keyed in location to pre­vent rotation. Patented** valve and in-line flow regulator pro­vides constant stream from 20 to 105 psi.
Protected by Elkay’s 5 Year Limited Warranty on the refrig­eration system of the unit.
Elkay Electric Air Cooled Water Coolers are listed by Underwriters Laboratories Inc., approved by C.S.A., rated in accordance with A.R.I. Standard 1010 and meet all known federal and state plumbing codes.
STANDARDS
Elkay Electric Air Cooled Water Coolers are listed by Underwriters Laboratories Inc. and comply with both Canadian and U.S. requirements.
These units comply with A.R.I. Standard 1010.
This cooler is certified by WQA to lead-free compliance including
NSF/ANSI 61-ANNEX G, AB 1953.
®
Safety Bubbler: Innovative design
In keeping with our policy of continuing product improvement, Elkay reserves the right to change product specifications without notice. Please visit elkayusa.com for most current version of Elkay
product specification sheets.
Elkay
elkayusa.com
2222 Camden Court Oak Brook, IL 60523
This specification describes an Elkay product with design, quality and functional benefits to the user. When making a comparison of other producers’ offerings, be certain these features are not overlooked.
Printed in U.S.A. ©2011 Elkay
(Rev. 4/11) 10-11H
OPEN AREA FOR PLUMBING CONNECTIONS
WALL MOUNTING HANGER
(FURNISHED)
OPTIONAL ELECTRICAL OUTLET LOCATION
FLOOR LINE
40"
(1016mm)
1-3/4"
(44mm)
11-3/4"
(298mm)
5-1/2"
(140mm)
1-1/2 FOOT (457mm) LONG
POWER CORD
1-1/4" (32mm) O.D. TAILPIECE (TRAP NOT FURNISHED)
13"
(330mm)
3"
(76mm)
C
L
4-1/2"
(114mm)
4-1/4"
(108mm)
4-1/4"
(108mm)
15"
(381mm)
14"
(356mm)
12-3/4"
(324mm)
15-3/4"
(400mm)
2-3/4"
(70mm)
2"
(51mm)
2"
(51mm)
6-1/2"
(165mm)
RECOMMENDED LOCATION
ELECTRICAL OUTLET
(BY OTHERS)
RECOMMENDED LOCATION 3/8" I.P.S. COLD WATER SUPPLY (STUB OUT FROM WALL 1" [25mm])
WASTE OUTLET – 1-1/4" I.P.S. (STUB OUT FROM WALL 1" [25mm])
Roughing-In Dimensions
Installation – A steel mounting hanger provides rigid support of the cooler on the wall. Install at normal bubbler height of approximately 40" (1016mm), or at a lower height for children. If recessed in an alcove, allow full opening beneath cooler, and at least 4" (102mm) or more on each side for air circulation.
FRONT VIEW SIDE VIEW
N
OTE: WATERFLOW
D
IRECTION
S
ERVICE STOP
(
NOT FURNISHED)
3
/8" O.D. TUBE CONNECT
C
OLD WATER SUPPLY 1/4" O.D. TUBE
WATER INLET
TO COOLER
B
UILDING WATER
I
NLET
N
OTE: WATERFLOW
D
IRECTION
S
ERVICE STOP
(
NOT FURNISHED)
3
/8" O.D. TUBE CONNECT
C
OLD WATER SUPPLY
1/4" O.D. TUBE WATER INLET TO COOLER
B
UILDING WATER
I
NLET
OPERATION OF QUICK CONNECT FITTINGS
S
IMPLY PUSH IN
TUBE TO ATTACH T
UBE IS SECURED
IN POSITION
P
USH IN COLLET
TO RELEASE TUBE
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
R
ELEASE TUBE
AB
C
OPERATION OF QUICK CONNECT FITTINGS
S
IMPLY PUSH IN
TUBE TO ATTACH
T
UBE IS SECURED
IN POSITION
P
USH IN COLLET
TO RELEASE TUBE
PUSHING TUBE IN BEFORE PULLING IT OUT HELPS TO
R
ELEASE TUBE
AB
C
No Lead Wall Mount Compact
®
Slant Front Water Cooler Models HEW3 and HEWD
RO U G H - I N D I M E N S I O N S
MPORTANT!
I
NSTALLER PLEASE NOTE:
This water cooler has been designed and built to provide water to the user which has not been altered by materials in the cooler waterways.
The grounding of electrical equipment such as telephone, computers, etc., to water lines is a common procedure. This grounding may be in the building but may also occur away from the building. This grounding can cause electrical feedback into a water cooler creating an electrolysis which creates a metallic taste or causes an increase in the metal content of the water. This condition is avoidable by installing the cooler using the proper materials as shown below.
his water cooler must be connected to the water supply using a dielectric coupling.
T
he cooler is furnished with a non-metallic strainer which meets this requirement.
T
he drain trap which is provided by the installer should also be plastic to completely
T
solate the cooler from the building plumbing system.
i
I
NOTICE
Elkay
10-11H (Rev. 4/11)
2222 Camden Court Oak Brook, IL 60523
Printed in U.S.A. ©2011 Elkay
Loading...