EZOTL8*1F EZOTL8*2F EZOTL8*3F
INSTALLATION, CARE & USE MANUAL
Manual de Instalación, Cuidado y Utilización
Manuel d’installation/entretien/utilisation
EZOTL™ Series Versatile Bi-Level Water Coolers
EZOTL™ Serie versátil bi-nivel enfriadores de agua
EZOTL™ Série versatile refroidisseurs d’eau à deux niveaux
Versatile Cooler Model EZOTL8
conguration as shipped
Versatile Cooler Model EZOTL8
alternate installation
Page 1
0000000875 (Rev. C - 01/15)
Uses HFC-134A refrigerant
Usa refrigerante HFC-134A
Utilise du uide frigorigéne HFC-134A
EZOTL8*1F EZOTL8*2F EZOTL8*3F
32
20
18
4
SEE FIG. 4
9
13
7
28
25
4
9
1
22
13
7
14
27
8
6
Sensor Eye
Adjustment Screw
14
27
SEE FIG. 3
13
11
3
0000000875 (Rev. C - 01/15)
27
21
2
9
FIG. 1
Page 2
27
31 5
26
23
13
16
17
24
EZOTL8*1F EZOTL8*2F EZOTL8*3F
3"
1 7/16"
76mm
37mm
19"
483mm
HANGER
BRACKET
FILTER
8 1/16"
205mm
RIM
HEIGHT
936mm
36 13/16"
HEIGHT
38 3/8"
ORIFICE
975mm
C
12 1/2"
318mm
27"
ADA
686mm
RIM
HEIGHT
31 5/16"
796mm
HEIGHT
32 7/8"
ORIFICE
835mm
REQUIREMENT
6 3/8"
6 3/8"
18 3/8"
467mm
STANDARD ROUGH-IN FOR BI-LEVEL MODELS
6 3/8"
18 3/8"
467mm
6 3/8"
2"
51mm
E
732mm
28 13/16"
21 7/8"
556mm
19"
483mm
D = ELECTRICAL SUPPLY (3) WIRE RECESSED BOX DUPLEX OUTLET
FIG. 2
ASEGURE UNA VENTILACIÓN ADECUADA MANTENIENDO UN ESPACIO E 6” (152 mm) (MÍN.)
DE HOLGURA ENTRE LA REJILLA DE VENTILACIÓN DEL MUEBLE Y LA PARED
ASSUREZ-VOUS UNE BONNE VENTILATION EN GARDANT 6” (152 mm) (MIN.) ENTRE LES
ÉVENTS DE L’ENCEINTE ET LE MUR.
ALAMBRES DE SUMINISTRO ELECTRICO (3) EN TOMA DUPLEX EMPOTRADO TIPO CAJA.
PRISE DOUBLE AVEC BOITIER ENCASTRE POUR ALIMENTATION ELECTRIQUE (3) FILS.
E = INSURE PROPER VENTILATION BY MAINTAINING 6” (152 mm) (MIN.) CLEARANCE FROM
CABINET LOUVERS TO WALL.
F = 7/16 BOLT HOLES FOR FASTENING UNIT TO WALL
AGUJEROS DE LAS TUERCAS DE 7/16 PARA SUJETAR LA UNIDAD A LA PARED
TROUS D’ÉCROUS 7/16 POUR FIXER L’APPAREIL AU MUR
**NEW INSTALLATIONS MUST USE GROUND FAULT CIRCUIT INTERRUPTER (GFCI)
**LAS NUEVAS INSTALACIONES DEBEN UTILIZAR LOS INTERRUPTORES DE
CIRCUITO DE TIERRA DE LA AVERÍA (GFCI)
**LES NOUVELLES INSTALLATIONS DOIVENT EMPLOYER LES INTERRUPTEURS DE CIRCUIT MOULUS DE
DÉFAUT (GFCI)
A
LOCATION
162mm
‰
PREFFERED
B
2"
51mm
3 7/8"
162mm
7"
178mm
98mm
5 3/4"
FINISHED FLOOR
7"
146mm
178mm
F
2"
7/8"
51mm
22mm
354mm
13 15/16"
162mm
‰
17 7/16"
443mm
REDUCE HEIGHT BY 3 INCHES FOR INSTALLATION OF CHILDRENS ADA COOLER
162mm
D
LOCATION
PREFFERED
E
DIA. ((12)
9/32"
7mm
2"
51mm
A
(ALT. LOCATION)
OPTIONAL FILTER
F
872mm
34 5/16"
24 1/2"
622mm
Page 3
19 7/16"
494mm
583mm
22 15/16"
PURGADOR DE 1-1/2 NO PROPORCIONADO**
SIPHON 1-1/2 NON FOURNI**
LEGEND/LEYENDA/LÉGENDE
A = RECOMMENDED WATER SUPPLY LOCATION 3/8 O.D. UNPLATED COPPER TUBE CONNECT STUB WITH
SHUT OFF (BY OTHERS) 3 IN. (76mm) MAXIMUM OUT FROM WALL
La UBICACION 3/8 O RECOMENDADA de ABASTECIMIENTO DE AGUA. D. El TUBO del COBRE de UNPLATED
CONECTA TALONARIO CON APAGO (POR OTROS) 3 en. (76 mm) el MAXIMO FUERA DE PARED
L’O.D de 3/8 d’EMPLACEMENT DE PROVISION D’EAU RECOMMANDE. LE TUBE DE CUIVRE DE UNPLATED
CONNECTE STUB AVEC ETEINT (PAR LES AUTRES) 3 dans. (76 mm) le MAXIMUM HORS DU MUR
B = RECOMMENDED LOCATION FOR WASTE OUTLET TO ACCOMADATE 1-1/2” NOMINAL DRAIN. DRAIN STUB
2 IN. OUT FROM WALL
LUGAR RECOMENDADO PARA La SALIDA DE RESIDUOS DEBERA ACOMODAR UN DESAGUE NOMINAL DE
1-1/2” (25.4mm). TRONCO DE DESAGUE DEBERA QUEDAR A UNA DISTANCIA DE 2 PULGADAS (50.8mm) DE
LA PARED.
EMPLACEMENT RECOMMANDE POUR La SORTIE D’EVACUATION DES DECHETS POUR UNE EVACUATION DE
1,5 PO (DIMENSION NOMINALE). TRONCON D’EVACUATION SORTANT DE 2 PO DU MUR.
C = 1-1/2 TRAP NOT FURNISHED**
0000000875 (Rev. C - 01/15)